TGA is a high-speed and high-precision process time measurement algorithm developed and implemented by our company through research on ultrasonic time measurement algorithms and reference to various existing TDC algorithms. The time measurement accuracy of TGA can reach tens of ps, and it also has the characteristics of simple and convenient installation of ultrasonic flow meters, which can be completed without breaking pipes or stopping water supply.

3. As the advantage of a clamp on flow meter, no need to cut off the pipe or long time stop the equipment, save the cost of time and labor costs.


2.Customized product - large pipe diameter


cross screw, expansion rubber plug, plug, certificate of conformity, instruction manual, calibration report, and packing list.

Parameter table | |
Pipe material | Metal /PVC, PP or PVDF rigid plastic pipe |
Liquid type | Water/other liquid (Single liquid medium without solid particles or impurities) |
Temperature range | 0-115ºC (No freezing on the surface) |
Low velocity cut off value (Default by factory) | 0.1m/s |
Display | 256*128, LCD |
Response time | 0.5~60s |
Accuracy | ±2%, (±1% after calibration) |
Data Storage period | 300ms |
Memory for data backup | EEPROM (Data storage: over 10 years, data read/write frequency: over 1 million times) |
Power and I/O connection | M12 type aviation plug |
Output | 4-20mA |
Communication | Modbus RS485 |
Options for output | OCT (pulse output)/ One relay alarm (please contact the factory) |
Power supply | 10-24V VDC |
Electric power | < 3W |
Protective circuit | Power reverse connection protection, Power surge protection, Output short circuit protection, Output surge protection |
Enclosure protection class | IP65 |
Environment temperature | -10 to 60°C (No freezing) |
Relative humidity | 35 to 85% RH (No condensation) |
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each XYZ axis |
Impact resistant | 100 m/s2 16 ms pulse, 1000 times each for X, Y and Z axis |
Main material | Aluminum, Industrial Plastics |
Cable length | 2m(standard ), PT1000 sensor standard cable length is 9m |