Dgnpd Type Transformer Neutral Point Grounding Protection Device

Price $10000.00 Compare
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 429 people viewed
Quantity
+-
 

Denggao Electric Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
  • Zhejiang, China
  • Linda (Ms.)  
    Project Manager
DGNPD
High Voltage Circuit Breakers
Manual Type
Vacuum
Fixed
Circuit Breaker
Conventional Circuit Breaker, Overcurrent Protection
-40ºC-+40ºC
Not Higher Than 90% (25ºC)
Not Over 3000m
48 ~ 52Hz
DGG
Export Box
China
8504311000
Product Description
Photos of Product

General

110kV and above power systems adopt the operation mode of neutral point direct grounding, commonly known as a high current effective grounding system. The neutral point of the transformer in operation is directly grounded, so there is no overvoltage and protection problem with the neutral point. However, in actual operation, in order to limit single-phase short circuit current, prevent communication interference, relay device setting configuration, and other requirements, the operation mode of ungrounded neutral points of some transformers is often adopted. Generally, only 30%~50% of the transformer neutral points are allowed to be directly grounded, so as to ensure the safe and stable operation of the system. In addition, in some ring or radial power supply networks, the dispatcher controls the power flow direction according to the operation needs and consciously arranges the neutral point of a certain intermediate terminal transformer to operate in a non-direct grounding mode. Obviously, under the condition of three-phase symmetry in the normal operation of the system, the neutral point potential is zero regardless of whether it is grounded or not, and there is no need to take overvoltage protection measures. However, in operation, it is often interfered with by various factors (such as lightning, operation, refusal to move, disconnection, single-phase grounding fault, etc.), and the neutral point of the transformer will have high overvoltage and be damaged, so it must be protected.

The electric power industry standard DLT620-1997 Overvoltage Protection and Insulation Coordination for AC Electrical Installations stipulates that "local ungrounded systems should be avoided in 110KV and 220KV effectively grounded systems, and excessive power frequency over-voltage should be generated. For such partially ungrounded systems, the over-voltage protection of 110kV and 220kV ungrounded neutral points with power supply on the low-voltage side should adopt the method of zinc oxide lightning arrester plus parallel clearance"

DGNPD series transformer neutral point gap grounding protection complete device (hereinafter referred to as the complete device) produced by our company is a complete device developed to protect against the damage of transformer neutral point insulation transformer overvoltage, switching overvoltage and power frequency [transient] overvoltage.


Model And Meaning


Usage Environmental Conditions

1. Outdoor Use
2. Ambient Temperature: Not lower than -40ºC, not higher than +40ºC
3. Relative Humidity: Not higher than 90% (25ºC)
4. Altitude: Not over 3000m
5. Power grid frequency: 48 ~ 52Hz (50Hz systems), 58 ~ 62Hz (60Hz systems)
6. Installation site: the air shall be free of chemical corrosive gas and steam, and explosive dust.


Technical Specification
 
Product CodeTransformer's Neutral point withstand
level
Zinc oxide arresterDischarge barrierIsolation Switch 
1.2/50μs Lightning Impulse Withstand Voltage (peak value) (kV)1 min Short-time Power frequency withstand Voltage(kV)Rated Voltage (effective value)
kV
Special long-distance voltage (effective value) kVDC 1mA reference voltage is not less than8/20μs 1.5kA lightning impulse current residual voltage is not less than kVPower frequency discharge voltage (effective value) ± 5% kVRated VoltagePeak Value Withstand Current (kA)10s Short-Time Withstand Current (kA)
DGNPD-85/180-601808560488614467.540015.54.2
DGNPD-95/250-722509572581031868140015.54.2
DGNPD-140/325-96325140967713726010840015.54.2
DGNPD-140/325-1023251401028215826011540015.54.2
DGNPD-200/400-14440020014411620532016240015.54.2
DGNPD-230/500-2075502002071662924402346305020
  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$10000.00 1 Piece(MOQ)

Low Losses Electric Electrical 630 kVA High Voltage Power Three Phase Oil Power/Transmission Immersed Distribution Transformer

Denggao Electric Co., Ltd.
$24.90 1 Piece(MOQ)

Three Phase Digital Voltmeter

Denggao Electric Co., Ltd.
$0.30 1 Piece(MOQ)

Advanced T-Type High-Voltage Fuse Link for Industrial Safety

Denggao Electric Co., Ltd.
$300.00 1 Piece(MOQ)

11kv 35kv CT/PT Indoor Single Phase Epoxy Resin Casting Type Instrument Current/Voltage/ Potential Transformer

Denggao Electric Co., Ltd.
$43.04 1 Piece(MOQ)

4p 250A Composite Point Electronic MCCB with System Versatility and High Performance

Yuming Electric Co., Ltd
$5.14 1000 Pieces(MOQ)

Settable Over Voltage and Under Voltage Protector

Yueqing Long Road Electric Co., Ltd.
$1800.00 1 Piece(MOQ)

(12kV/1250A-25kA) High Voltage Recloser /ZW32-12 Outdoor Vacuum Circuit Breaker for Swithchgear

Wuhan Feite Electric Co., Ltd.
$4700.00 1 Piece(MOQ)

40.5kv Hv Indoor Side-Mounted Fixed Vacuum Circuit Breaker

HENSWELL ELECTRIC CO., LTD.
$98.85 1 Piece(MOQ)

Zjsb9-125z Series Tuya 4G SIM Card Smart Mini Circuit Breakers, Tuya 4G Cat1 IoT Intelligent Circuit Breaker

Yueqing Tianze Elec. Co., Ltd.
$4.00 100 Pieces(MOQ)

Disjoncteur 63A DC MCB 1p 2p 4p DIN Rail Mounting Miniature Circuit Breaker

Gandian Lightning Protection Electric Co., Ltd.