Introduction

Operational principle

The current transformer built in the cutout sectionalizer can detect the current of the main circuit and send the output to the electronic control for digital handling. When a fault occurs, the upstream recloser (or circuit breaker) opens, the circuit loses voltage and the current is lower than 300mA, the electronic controller can remember this opening time as a "count". As it accumulate the presetting number (1 to 4), the sectionalizer will automatic trips within 180ms of fault interruption to isolate fault. Then the upstream recloser (or circuit breaker) closes to restore power supply to the healthy section of the system to limit outage scope and protect the main feeder in service. If the fault is temporary and is cleared before the sectionalizer counter reaches the presetting number, the sectionalizer remains closed and resets to its original state after its reset time expires.

Counts
The number of counts differentiates real faults from transient faults. When the preset number of countsis registered, the electronic sectionalizer willoperate.
The sectionalizer can be set to 1, 2, 3, 4 counts. It registers a count when a current dead time exceeding200 milliseconds occurs, immediately after a current pick up. This ensures the sectionalizer only registers acount when a recloser has tripped due to a faultcurrent.
The count setting should be one count less than the immediate upstreamrecloser.

Pick upcurrent
The pick up current is the threshold, which must be exceeded in order to register a count. The pick up requires a minimum fault pulse that is 10% greater than the pick up current setting and is longer than 20 milliseconds in duration.

Resetting
Theelectronicsectionalizerwillresetitselfduringthedropoutoperation.Do not need remove the unit from itsmount using a hook stick and reset itmanually.

Service conditions
1.The ambient air temperature is not above 55ºC or below-40ºC.
2.Theaveragevalueoftheambienttemperature,measuredoveraperiodof24h,doesnotexceed 25ºC.
3.The altitude does not exceed 1000 m(3300ft).
4.The wind speed does not exceed 34 m/s (corresponding to 700 Pa on cylindricalsurfaces).
5.The ice coating does not exceed1mm.
6.Thesectionalizershouldnotapplytothoseflammable,explosive,corrosiveandseverevibrationconditions. As to other service conditions not covered in the manual, please contact and consult with the manufacturerfor detailinformation.

Designator and itsmeaning



Technical data
Rated actuating current: 8 to400A
Reclaim time: 20±5%s
Operation counts:1-4
Sensitivity of pick up current:±10%
Max. load current prior to operation: 0.3A
Min. recloser dead time: 500ms
Min. duration of fault pulse:10ms



  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$2.00 1000 Pieces(MOQ)

Aluminium Copper Fitting Pg Clamp

Zhejiang Haivo Electrical Co., Ltd.
$10.00 1 Piece(MOQ)

Expulsion Fuse Links for Fuse Cutout

Zhejiang Haivo Electrical Co., Ltd.
$22.00 1 Piece(MOQ)

36kv Outdoor High Quality on Load Break Switch

Zhejiang Haivo Electrical Co., Ltd.
$20.00 2 Pieces(MOQ)

High Voltage Post Porcelain Insulators

Zhejiang Haivo Electrical Co., Ltd.
Negotiable 20 Pieces(MOQ)

Low Voltage Nt4 HRC Square Blade Ceramic Fuse Link

ZHEJIANG FUERZI ELECTRIC TECHNOLOGY CO., LTD.
$16.70 100 Pieces(MOQ)

High Breaking Capacity Long Life Nh Blade Knife H Type Fuse Link

Wenzhou Homor International Trade Co., Ltd.
$0.03 1500 Pieces(MOQ)

PPTC SMD Surface Mount Devices Resettale Fuse 1812 Standard Size

Shenzhen Kangtai Songlong Electronic Technology Co., Ltd.
$45.00 100 Pieces(MOQ)

33kv 36kv Polymer Dropout Fuse Cutout with Fuse Holder 100A Cutout Switch Silicone Rubber Fuse Cut out Electrical Fuse for Distribution Power System

Zhejiang Yuanneng Power Technology Co., Ltd.
$1.55 100 pieces(MOQ)

Nh/Nt00 Higher Cost Performance Rated Voltage of 660V (50Hz) for HRC Fuse, Nt00 Fuse Base

Yueqing Jasco Electric Co., Ltd.
$10.00 10 Pieces(MOQ)

10-12kv 100A 200A Porcelain Expulsion Drop out Fuse Cut out Fuse

Dalian Electric International Co., Ltd