RDK-
High
Current Fuse
High Voltage
Spiral
F
Discoloration
VDE
Outdoor Expulsion Drop-out Type
HAIVOL
Carton
27kv 100/200a
China
8535100000
Product Description
Introduction

Operational principle

The current transformer built in the cutout sectionalizer can detect the current of the main circuit and send the output to the electronic control for digital handling. When a fault occurs, the upstream recloser (or circuit breaker) opens, the circuit loses voltage and the current is lower than 300mA, the electronic controller can remember this opening time as a "count". As it accumulate the presetting number (1 to 4), the sectionalizer will automatic trips within 180ms of fault interruption to isolate fault. Then the upstream recloser (or circuit breaker) closes to restore power supply to the healthy section of the system to limit outage scope and protect the main feeder in service. If the fault is temporary and is cleared before the sectionalizer counter reaches the presetting number, the sectionalizer remains closed and resets to its original state after its reset time expires.

Counts
The number of counts differentiates real faults from transient faults. When the preset number of countsis registered, the electronic sectionalizer willoperate.
The sectionalizer can be set to 1, 2, 3, 4 counts. It registers a count when a current dead time exceeding200 milliseconds occurs, immediately after a current pick up. This ensures the sectionalizer only registers acount when a recloser has tripped due to a faultcurrent.
The count setting should be one count less than the immediate upstreamrecloser.

Pick upcurrent
The pick up current is the threshold, which must be exceeded in order to register a count. The pick up requires a minimum fault pulse that is 10% greater than the pick up current setting and is longer than 20 milliseconds in duration.

Resetting
Theelectronicsectionalizerwillresetitselfduringthedropoutoperation.Do not need remove the unit from itsmount using a hook stick and reset itmanually.

Service conditions
1.The ambient air temperature is not above 55ºC or below-40ºC.
2.Theaveragevalueoftheambienttemperature,measuredoveraperiodof24h,doesnotexceed 25ºC.
3.The altitude does not exceed 1000 m(3300ft).
4.The wind speed does not exceed 34 m/s (corresponding to 700 Pa on cylindricalsurfaces).
5.The ice coating does not exceed1mm.
6.Thesectionalizershouldnotapplytothoseflammable,explosive,corrosiveandseverevibrationconditions. As to other service conditions not covered in the manual, please contact and consult with the manufacturerfor detailinformation.

Designator and itsmeaning



Technical data
Rated actuating current: 8 to400A
Reclaim time: 20±5%s
Operation counts:1-4
Sensitivity of pick up current:±10%
Max. load current prior to operation: 0.3A
Min. recloser dead time: 500ms
Min. duration of fault pulse:10ms



  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$22.00 2 Pieces(MOQ)

27kv Breaking Overcurrent Fuse Cutout

Zhejiang Haivo Electrical Co., Ltd.
$60.00 3 Pieces(MOQ)

15kv 630A/20kv 630A IEC Type Tee Connector Cable Accessories

Zhejiang Haivo Electrical Co., Ltd.
$22.00 2 Pieces(MOQ)

Epoxy-Fiber Glass Fuse Tube for Fuse Cutout

Zhejiang Haivo Electrical Co., Ltd.
$12.00 2 Pieces(MOQ)

33kv Cable Termination Kit Electrical Connect

Zhejiang Haivo Electrical Co., Ltd.
$25.00 1 Piece(MOQ)

140A Smrs Dual Sensing Fuse Wire

ANHUANG ELECTRIC POWER TECHNOLOGY CO., LTD.
$100.00 1 Piece(MOQ)

New Ferraz/Mersen Nh Type Fuse

Jiangsu Core Drill Age Electronic Technology Co., Ltd
$0.50 100 Pieces(MOQ)

Alloyed K Type T Type High Voltage Fuse Link with Movable Head Button

Zhejiang Shanmeng Electric Co., Ltd.
$45.00 100 Pieces(MOQ)

12kv 200A Porcelain Expulsion Dropout Fuse Cutout

Wenzhou Yikun Electric Co., Ltd.
$4.15 1000 Pieces(MOQ)

Bakelite Low Voltage Single Pole 60A 80A 100A 200A Cut-out Fuse; 60A/80A Sp&N (Single Pole and Neutral) Cutout Fuses

Yueqing Tianze Elec. Co., Ltd.
$0.03 1000 Pieces(MOQ)

Micro Radial Lead Fuse 350V 8*4*7mm 500mA 630mA

Reomax Electronics Co., Ltd.