The lightning arrester is the basis for insulation coordination of various electrical equipment (such as transformer, reactor, capacitor, generator, motor, PT, CT, circuit breaker, contactor, etc.) in the power system. The internal and external insulation indexes (short-time power frequency withstand voltage, lightning impulse withstand voltage, operation impulse withstand voltage, etc.) of all electrical equipment in the power system are determined by the protection performance of the lightning arrester.
Purpose And Executive Standard
This product is used in power generation, transmission, transformation, and distribution systems of AC 220kV and below, and is used to limit the amplitude of lightning and internal switching overvoltage of the system to the specified level. It is the basic equipment for insulation coordination of the entire system. At the same time, this product cannot be used to limit resonance overvoltage, and other methods are required for system harmonic elimination.
The model of this product is prepared in accordance with JB/T 8459-2006 Preparation Method of Arrester Product Model and gapless products shall comply with GB 11032-2000 AC Gapless Metal Oxide Arrester;
The products with gaps shall comply with the standard of Metal Oxide Surge Arresters with Series Gaps (J B/T 9672-2005).
Important parameters and configuration methods not clearly defined in the above standards shall be corrected according to the requirements of DL/T 620-1997 Overvoltage Protection and Insulation Coordination for AC Electrical Installations.
The normal use conditions of conventional products are as follows:
- Ambient temperature: no higher than+40 ºC, no lower than - 40 ºC;
- Altitude: no more than 3000 m;
- Power frequency: 50 ± 2Hz; 60±2Hz;
- Maximum wind speed: 35m/s;
- Cleaning-free conditions: areas with medium pollution and below;
- For gapless products, the power frequency voltage applied for a long time shall not exceed the continuous operation voltage of the arrester;
- For products with gaps, the short-time power frequency voltage rise at the installation point shall not exceed the rated voltage of the arrester.
- The temperature or altitude exceeds the standard (such as plateau, tropical zone, cold zone, fully enclosed cabinet, close to an electric furnace, etc.);
- The use environment has serious moisture or corrosive gas impurities (such as water, salt fields, chemical plants, etc.);
- Strong ultraviolet radiation (such as plateau, drought area with strong sunshine, etc.);
- Extremely polluted areas (such as mine working face, construction site working face, etc)
The technical parameters of the form are for reference only.
Model | MOA Rated | MCOV | 1/10μs Steep Current Impulse | 8/20μs Lightning Current Impulse | 30/60μs Switching Current Impulse | 2ms Rectangular Current Impulse Withstand | 4/10μs High Current Impulse Withstand |
kV (r.m.s) | ≮kV | A | kA | ||||
YH5W-3 | 3 | 2.55 | 11.3 | 9 | 8.90 | 150 | 65 |
YH5W-6 | 6 | 5.10 | 22.6 | 18 | 16.8 | 150 | 65 |
YH5W-9 | 9 | 7.65 | 33.7 | 27 | 23.8 | 150 | 65 |
YH5W-10 | 10 | 8.40 | 36.0 | 30 | 26.4 | 150 | 65 |
YH5W-11 | 11 | 9.40 | 40.0 | 33 | 30.0 | 150 | 65 |
YH5W-12 | 12 | 10.2 | 42.2 | 36 | 31.7 | 150 | 65 |
YH5W-15 | 15 | 12.7 | 51.0 | 45 | 38.5 | 150 | 65 |
YH5W-18 | 18 | 15.3 | 61.5 | 54 | 46.5 | 150 | 65 |
YH5W-21 | 21 | 17.0 | 71.8 | 63 | 54.5 | 150 | 65 |
YH5W-24 | 24 | 19.5 | 82.0 | 72 | 62.6 | 150 | 65 |
YH5W-27 | 27 | 22.0 | 92.0 | 81 | 69.8 | 150 | 65 |
YH5W-30 | 30 | 24.4 | 102 | 90 | 79.0 | 150 | 65 |
YH5W-33 | 33 | 27.5 | 112 | 99 | 86.7 | 150 | 65 |
YH5W-36 | 36 | 29.0 | 117 | 103 | 92.4 | 150 | 65 |
YH5W-39 | 39 | 31.5 | 123 | 108 | 94.0 | 150 | 65 |
YH5W-42 | 42 | 34.0 | 126 | 111 | 101 | 150 | 65 |
YH5W-45 | 45 | 36.5 | 128 | 119 | 105 | 150 | 65 |
YH5W-48 | 48 | 39.0 | 139 | 127 | 110 | 150 | 65 |
YH5W-51 | 51 | 40.8 | 151 | 134 | 115 | 150 | 65 |
YH5W-54 | 54 | 42.0 | 160 | 143 | 119 | 150 | 65 |
YH5W-60 | 60 | 48.0 | 178 | 159 | 132 | 150 | 65 |
YH5W-66 | 66 | 53.0 | 196 | 175 | 145 | 150 | 65 |
YH5W-69 | 69 | 55.2 | 205 | 183 | 152 | 150 | 65 |
Model | MOA Rated | MCOV | 1/10μs Steep Current Impulse | 8/20μs Lightning Current Impulse | 30/60μs Switching Current Impulse | 2ms Rectangular Current Impulse Withstand | 4/10μs High Current Impulse Withstand |
kV (r.m.s) | ≮kV | A | kA | ||||
YH10W-3 | 3 | 2.55 | 10.3 | 8.40 | 7.70 | 250 | 100 |
YH10W-6 | 6 | 5.10 | 20.5 | 16.7 | 15.4 | 250 | 100 |
YH10W-9 | 9 | 7.65 | 31.0 | 25.0 | 23.1 | 250 | 100 |
YH10W-10 | 10 | 8.40 | 33.0 | 27.4 | 27.0 | 250 | 100 |
YH10W-11 | 11 | 9.40 | 36.4 | 30.4 | 30.0 | 250 | 100 |
YH10W-12 | 12 | 10.2 | 38.5 | 33.3 | 30.8 | 250 | 100 |
YH10W-15 | 15 | 12.7 | 46.5 | 41.4 | 38.5 | 250 | 100 |
YH10W-18 | 18 | 15.3 | 56.0 | 49.8 | 46.2 | 250 | 100 |
YH10W-21 | 21 | 17.0 | 65.5 | 57.0 | 53.9 | 250 | 100 |
YH10W-24 | 24 | 19.5 | 75.0 | 65.0 | 61.6 | 250 | 100 |
YH10W-27 | 27 | 22.0 | 84.0 | 74.0 | 69.3 | 250 | 100 |
YH10W-30 | 30 | 24.4 | 93.0 | 82.0 | 76.5 | 250 | 100 |
YH10W-33 | 33 | 27.5 | 101 | 90.0 | 84.7 | 250 | 100 |
YH10W-36 | 36 | 29.0 | 112 | 98.0 | 92.4 | 250 | 100 |
YH10W-39 | 39 | 31.5 | 117 | 103 | 94.0 | 250 | 100 |
YH10W-42 | 42 | 34.0 | 126 | 111 | 101 | 250 | 100 |
YH10W-45 | 45 | 36.5 | 128 | 119 | 105 | 250 | 100 |
YH10W-48 | 48 | 39.0 | 139 | 127 | 110 | 250 | 100 |
YH10W-51 | 51 | 40.8 | 151 | 134 | 115 | 250 | 100 |
YH10W-54 | 54 | 42.0 | 160 | 143 | 119 | 250 | 100 |
YH10W-60 | 60 | 48.0 | 178 | 159 | 132 | 400 | 100 |
YH10W-66 | 66 | 53.0 | 196 | 175 | 145 | 400 | 100 |
YH10W-69 | 69 | 55.2 | 205 | 183 | 152 | 400 | 100 |
YH10W-72 | 72 | 57.0 | 214 | 191 | 158 | 400 | 100 |
YH10W-75 | 75 | 60.0 | 223 | 199 | 165 | 400 | 100 |
YH10W-84 | 84 | 70.0 | 249 | 218 | 181 | 600 | 100 |
YH10W-90 | 90 | 70.0 | 249 | 234 | 184 | 600 | 100 |
YH10W-96 | 96 | 76.0 | 265 | 247 | 201 | 600 | 100 |
YH10W-108 | 108 | 84.0 | 298 | 273 | 222 | 600 | 100 |
YH10W-120 | 120 | 98.0 | 338 | 319 | 259 | 600 | 100 |
YH10W-132 | 132 | 106 | 367 | 345 | 280 | 600 | 100 |
YH10W-144 | 144 | 115 | 397 | 374 | 304 | 600 | 100 |
YH10W-168 | 168 | 131 | 452 | 426 | 346 | 600 | 100 |
YH10W-172 | 172 | 140 | 483 | 455 | 370 | 600 | 100 |
YH10W-180 | 180 | 144 | 497 | 468 | 380 | 600 | 100 |













Our dedicated team excels in crafting the most cost-effective and innovative power solutions, tailored precisely for our clients' needs. We actively contribute to the design of sophisticated substation and distribution plans and engage in competitive overseas bidding. We have triumphantly addressed and resolved intricate product requirements, ensuring our clients' utmost satisfaction.
Our credentials are bolstered by the acclaimed ISO certification . Additionally, we possess an extensive collection of diverse type test reports that exemplify the unparalleled quality and reliability of our products.


Q1: Are you a trading company or manufacturer ?
A1: We are a professional factory with 7 years experience in the field of high and low voltage power transformers, substation, vacuum circuit breaker, power equipment.
Q2: Do you accept customized serveice ?
A2: We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters .
A3: Our MOQ is 1 piece.
Q4: How long is your delivery lead time ?
A4: It depends on your product requirement and quantity . Generally , 5~10 working days is avaliable .
A5: Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make asatisfied soluton within 2 days .
A6: Depending upon the port of delivery, prices varies.
Q7: What is your payment terms ?
A7: 30%T/T in adcance,70% before shipment . West union , L/C are also acceptable .