Features
· Power supply: Independent power supply
· Number of channels: 1 in/1 out, 1 in/2 out, 2 in/2 out
· Functions: signal isolation transmission, transmission conversion, distribution
· Matching signal and intrinsically safe instrument:
Switch, proximity Switch Input
Intrinsically safe power supply output for driving intrinsically safe solenoid valves and indicator lamps
Two-wire and three-wire transmitter input (including HART)
Current signal input/output
Thermocouple, millivolt signal, thermal resistance input
Standards
· GB/T 3836.1-2021 "Explosive Environments Part 1: General Requirements for Equipment"
· GB/T 3836.4-2021 "Explosive Environments Part 4: Intrinsically safe 'i' Protected Equipment"
· GB/T 3836.20-2010 "Explosive Environments Part 20: Equipment Protection Rank (EPL) Ga Devices"
· IEC 61508 Parts 1-7: 2010
· IEC 61326-3-1: 2017
· IEC 61298 Parts 1-3: 2008
Certificates
· National Instrument Explosion-proof Safety Supervision and Inspection Station Explosion-proof certification
· AM1000EX.SIL series isolation grid, explosion-proof certificate number: GYB18.1229
· Chinese National Compulsory Product Certification (CCC)
General Technical Parameters
· Power supply protection: power supply reverse protection
· Safety isolation: Safety side and dangerous side isolation safety voltage 250V AC
· Insulation strength: 2500V AC; 1min (intrinsically safe end and non-intrinsically safe end) electromagnetic compatibility:
· Electromagnetic compatibility:
IEC 61326-1 (GB/T18268), IEC 61326-3-1
Electrostatic: air discharge 8kV
Pulse group: power line to ground 3kV, signal line to ground 2kV Surge: line to ground 2kV, line to line 2kV
Radio frequency: 20V/m
· Using environment:
It must be installed in a safe environment without explosive gases, and there must be no strong vibration, impact, or corrosive gases and dust in the surrounding environment
Continuous working temperature: -20 ºC to + 60 ºC
Relative humidity: 10% ~ 90%
· Storage conditions:
Temperature:-40 ºC to + 80 ºC
Relative humidity: 10% to 90%
Structure and Dimensions
· Instrument structure: DME series molded case structure
· Installation method: in a safe place, DIN35mm standard guide rail
· Terminal block: pluggable, blue terminal is connected to dangerous side signal, gray terminal is connected to safe side signal, 0.5 mm2 ~ 2.5 mm2 multi-bundle or single-strand cable can be connected
· Dimensions:
114.5 mm × 99.0 mm × 12.5 mm (depth × height × width)
114.5 mm × 99.0 mm × 17.5 mm (depth × height × width)

Packaging & Delivery
Category | International Commercial Terms (Incoterms) | Terms of Payment | Nearest Port |
AM1000EX.SIL Isolated Barrier | CIF, CFR, DAP | LC, T/T, D/P | Shanghai, Guangzhou, Tianjin |