CYX series piezoresistive pressure sensor adopts the internationally advanced high stability and high precision silicon pressure chip, and adopts the sintering seat with stress optimization design, which is produced by the processes of chip mounting, gold wire bonding, diaphragm welding, high vacuum oil injection, pressure cycle stress relief, high temperature aging, temperature compensation, etc. With more than 30 years of development, production experience and technological innovation, the products have excellent stability and performance, and are widely recognized by users.
1.1 General CYX19 pressure sensor
The shape, assembly size and sealing method of the general CYX19 are consistent with the same kind of international mainstream products, which gives CYX19 good interchangeability. It is widely used in the pressure detection of the medium compatible with SS316L, NBR or Viton.
1.2 CYX19 pressure sensor with chloride ion corrosion resistance
CYX19Ti pressure sensor shares the same shape, assembly dimension and sealing form as the general CYX19. Structure uses titanium alloy: TC4 with high strength and good corrosion resistance is selected as the shell, TA1 is selected as the diaphragm, which is more suitable for the medium with strong corrosion of chloride ions such as seawater. Working in humid atmosphere and sea water medium, its corrosion resistance is far superior to that of stainless steel products. It has strong resistance to pitting, acid and stress corrosion, and excellent corrosion resistance to organic substances of alkali / chloride /chlorine, nitric acid, sulfuric acid, etc. Measurement range is -100kPa ~ 0 ~ 10kPa…100MPa.
1.3 Negative pressure measuring CYX series (model + Y)
Through the production of special negative pressure technology, the general pressure sensor and other models can reliably detect pressure below atmospheric pressure, and the range is between -100kPa ~ 3MPa.
2 Product features
3 Application
industrial process control liquid level measurement
gas and liquid pressure measurement pressure detection and calibration instrument
pressure switch and hydraulic system well monitoring
refrigeration equipment and air conditioning system fire Internet of things
4 Technical indicators
4.1 Electrical performance
Range | Full scale output (mV) | Typical value | Pressure form | Range | Full scale output (mV) | Typical value | Pressure form | |
0~10kPa | 35~60 | 45 | G | 0~1.6MPa | 125~185 | 150 | G/A | |
0~20kPa | 70~110 | 90 | G | 0~2.0MPa | 50~70 | 60 | G/A | |
0~35kPa | 55~80 | 70 | G/A | 0~3.5MPa | 100~120 | 110 | G/S/A | |
0~70kPa | 55~80 | 60 | G/A | 0~7.0MPa | 120~150 | 135 | S/A | |
0~100kPa | 60~85 | 75 | G/A | 0~10MPa | 180~230 | 200 | S/A | |
0~200kPa | 65~85 | 75 | G/A | 0~25MPa | 140~170 | 150 | S/A | |
0~400kPa | 60~80 | 70 | G/A | 0~40MPa | 230~280 | 250 | S/A | |
0~600kPa | 90~120 | 100 | G/A | 0~60MPa | 100~160 | 130 | S/A | |
0~1.0MPa | 80~120 | 100 | G/A | 0~100MPa | 100~150 | 120 | S/A |
Parameters | Typical value | Max value | Unit |
Full scale output | 100 | 250 | mV |
Zero output | ± 1 | ± 2 | mV |
Nonlinearity | 0.2 | 0.5 | %FS |
Hysteresis | 0.05 | 0.08 | %FS |
Repeatability | 0.05 | 0.08 | %FS |
Input / output impedance | 2.6 | 5.0 | kΩ |
Zero temperature drift (note 1) | ±0.4 | ±1.0 | %FS, @25ºC |
Sensitivity temperature drift (note 2) | ±0.4 | ±1.0 | %FS, @25ºC |
Long-term stability | 0.2 | 0.3 | %FS / year |
Excitation current | 1.5 (the maximum input voltage can be 10V) | mA | |
Insulation resistance | 500(100VDC) | MΩ | |
Compensation temperature (note 3) | 0~50; -10~70 | ºC | |
Working temperature | -40~+125 | ºC | |
Storage temperature | -40~+125 | ºC | |
Response time | ≤1 | ms | |
Housing and diaphragm material | stainless steel 316L | ||
O-ring | viton, nitrile rubber, silicone rubber | ||
Measuring medium | Fluids compatible with 316L, NBR or Viton or silicone | ||
Life (25 ºC) | > 1 × 108 pressure cycle (80% FS) | times | |
Filling medium | silicone oil | ||
Sealing ring | Φ 16 × 1.8mm (nitrile or fluorinated rubber (note 4)) | ||
Note 1 & 2. 0-10kPa zero temperature drift and sensitivity temperature drift: typical value is 0.5% FS @ 25 ºC, maximum value is 1.2% FS @ 25 ºC. Note 3. compensation temperature 0~ 50 ºC for ranges ≤200kPa; - 10ºC~ 70 ºC for ranges >200kPa. Note 4. temperature resistance range of viton seal ring is - 20 ºC ~ 200 ºC, low temperature performance is poor, When the temperature is lower than - 20 ºC, please verify before using. |
5 Model structure selection
5.1 Pressure sensor model selection and outline drawing
Series | Range | Model | Outline drawing |
CYX19 | -100kPa~10MPa | CYX1901 | ![]() |
CYX1901P | ![]() | ||
25MPa~100MPa | CYX1902 | ![]() |

6 Schematic diagram and wiring mode

IN + (red wire) - power supply positive | IN - (black wire) - power supply negative | |
S + (yellow wire) - output positive | S - (blue wire) - output negative |
7 Application Tips
- The "floating" sealing structure of O-ring on the side wall is recommended for sealing the pressure sensor, which can avoid the front end being compressed and the stability being affected.
- Pay attention to protect the front diaphragm and the compensation circuit board at the rear end, so as not to affect the performance or cause damage to the pressure sensor.
- The shell cavity shall be designed with tapered angle as shown in the figure, which is easy for assembly and can prevent the seal ring from being scratched by right angle.
- During assembly, pay attention to the tolerance fit between the pressure sensor size and the inner shell of the transmitter. It is recommended that the cavity be processed according to + 0.02 - + 0.05 of the pressure sensor diameter to achieve the required air tightness.
- During assembly, it is required to place vertically and press down evenly to prevent the shell from jamming or damaging the compensation plate.
- Do not press the metal diaphragm with hands or hard objects to avoid damaging the pressure sensor due to chip deformation or perforation.
- When wiring, the pins should not be cut too short, the length is generally no less than 5mm, and the welding time is no more than 5s.
- The pressure lead-in tube at the back of G type pressure sensor shall be connected with the atmosphere; water, steam or corrosive medium shall not enter the reference cavity at the back of the sensor body.
- Avoid falling, crashing, etc., which will affect the stability of the product.
- In case of any change of pin lead, the label with the pressure sensor shall prevail.