Module | BNT003KTL | BNT004KTL | BNT005KTL | BNT006KTL | BNT008KTL | BNT010KTL |
PV Input Data | ||||||
Max. DC Power ( W ) | 5100 | 6000 | 7500 | 9000 | 12000 | 15000 |
Max. DC Voltage ( V ) | 1100 | |||||
MPPT Voltage Range ( V ) | 150 - 1000 | |||||
MPPT Full Power Voltage Range ( V ) | 200 - 850 | 250 - 850 | 300 - 850 | 500 - 850 | ||
Rated Input Voltage ( V ) | 620 | |||||
Start-up Voltage ( V ) | 150 | |||||
Max. Input Current ( A ) | 15 x 2 | |||||
Max. Short Current ( A ) | 25 x 2 | |||||
No. of MPP Tracker / No. of PV String | 2/2 | |||||
Input Connector Type | MC4 | |||||
AC Output Data | ||||||
Max. Output Power ( VA ) | 3300 | 4400 | 5500 | 6600 | 8800 | 11000 |
Nominal Output Power ( W ) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 |
Max. Output Current ( A ) | 5.3 | 7 | 8.5 | 10.5 | 13.5 | 17 |
Nominal Output Voltage ( V ) | 3P+N+PE /3P+PE 230/400 | |||||
Grid Voltage Range | 260Vac-519Vac (according to local standard) | |||||
Nominal Output Frequency ( Hz ) | 50/60 | |||||
Grid Frequency Range | 45-55Hz/55-65Hz(according to local standard) | |||||
Output Power Factor | 1 default (adjustable from 0.8 leading to 0.8 lagging) | |||||
Output Current THD | <3% | |||||
Efficiency | ||||||
Max. Efficiency | 98.30% | 98.70% | ||||
Euro Efficiency | 97.61% | 97.65% | 98.00% | 98.05% | 98.23% | |
Protection | ||||||
PV Reverse Polarity Protection | YES | |||||
PV Insulation Resistance Detection | YES | |||||
AC Short Circuit Protection | YES | |||||
AC Over Current Protection | YES | |||||
AC Over Voltage Protection | YES | |||||
Anti-Islanding Protection | YES | |||||
Residual Current Detection | YES | |||||
Over Temperature Protection | YES | |||||
Integrated DC switch | YES | |||||
Surge Protection | Integrated (Type II) | |||||
Smart IV Curve Scaning | YES | |||||
Quick Arc Fault Circuit Interruption | Optional | |||||
General Data | ||||||
Dimensions (W x H x D, mm) | 370 x 510 x 167 | 370 x 510 x 192 | ||||
Weight ( kg ) | 16 | |||||
Protection Degree | IP65 | |||||
Enclosure Material | Aluminum | |||||
Ambient Temperature Range (°C ) | -25 to 60 | |||||
Humidity Range | 0 -100% | |||||
Topology | Transformerless | |||||
Communication Interface | RS485 / WiFi / Wire Ethernet / GPRS (optional) | |||||
Cooling Concept | Convection | Intelligent fan cooling | ||||
Noise Emission ( db ) | <30 | |||||
Night Power Consumption ( W ) | <1 | |||||
Max. Operation Altitude ( m ) | ≤4000 | |||||
Certifications and Standards | ||||||
EMC Standard | EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 | |||||
Safety Standard | IEC 60068, UL1741, EN62109 | |||||
Grid-connection | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 |
Module | BNT012KTL | BNT013KTL | BNT015KTL | BNT017KTL | BNT020KTL | BNT025KTL |
PV Input Data | ||||||
Max. DC Power ( W ) | 18000 | 19500 | 22500 | 25500 | 30000 | 37500 |
Max. DC Voltage ( V ) | 1100 | |||||
MPPT Voltage Range ( V ) | 150 - 1000 | |||||
MPPT Full Power Voltage Range ( V ) | 500 - 850 | |||||
Rated Input Voltage ( V ) | 620 | |||||
Start-up Voltage ( V ) | 150 | |||||
Max. Input Current ( A ) | 15 x 2 | 20 + 32 | 32 x 2 | |||
Max. Short Current ( A ) | 25 x 2 | 30 + 48 | 48 x 2 | |||
No. of MPP Tracker / No. of PV String | 2/2 | 2/3 | 2/4 | |||
Input Connector Type | MC4 | |||||
AC Output Data | ||||||
Max. Output Power ( VA ) | 13200 | 14300 | 16500 | 18700 | 22000 | 27500 |
Nominal Output Power ( W ) | 12000 | 13000 | 15000 | 17000 | 20000 | 25000 |
Max. Output Current ( A ) | 21.5 | 22 | 27 | 30 | 32 | 40 |
Nominal Output Voltage ( V ) | 3P+N+PE /3P+PE 230/400 | |||||
Grid Voltage Range | 260Vac-519Vac (according to local standard) | |||||
Nominal Output Frequency ( Hz ) | 50/60 | |||||
Grid Frequency Range | 45-55Hz/55-65Hz(according to local standard) | |||||
Output Power Factor | 1 default (adjustable from 0.8 leading to 0.8 lagging) | |||||
Output Current THD | <3% | |||||
Efficiency | ||||||
Max. Efficiency | 98.70% | 98.75% | ||||
Euro Efficiency | 98.23% | 98.35% | ||||
Protection | ||||||
PV Reverse Polarity Protection | YES | |||||
PV Insulation Resistance Detection | YES | |||||
AC Short Circuit Protection | YES | |||||
AC Over Current Protection | YES | |||||
AC Over Voltage Protection | YES | |||||
Anti-Islanding Protection | YES | |||||
Residual Current Detection | YES | |||||
Over Temperature Protection | YES | |||||
Integrated DC switch | YES | |||||
Surge Protection | Integrated (Type II) | |||||
Smart IV Curve Scaning | YES | |||||
Quick Arc Fault Circuit Interruption | Optional | |||||
General Data | ||||||
Dimensions (W x H x D, mm) | 370 x 510 x 192 | 370 x 535 x 192 | ||||
Weight ( kg ) | 16 | 17 | 19 | |||
Protection Degree | IP65 | |||||
Enclosure Material | Aluminum | |||||
Ambient Temperature Range (°C ) | -25 to 60 | |||||
Humidity Range | 0 -100% | |||||
Topology | Transformerless | |||||
Communication Interface | RS485 / WiFi / Wire Ethernet / GPRS (optional) | |||||
Cooling Concept | Intelligent fan cooling | |||||
Noise Emission ( db ) | <40 | <51 | ||||
Night Power Consumption ( W ) | <1 | |||||
Max. Operation Altitude ( m ) | ≤4000 | |||||
Certifications and Standards | ||||||
EMC Standard | EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 | |||||
Safety Standard | IEC 60068, UL1741, EN62109 | |||||
Grid-connection | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 |



We provide the highest quality products and the most professional services. We provide different design solutions for large, medium and small customers.
We continue to develop and improve technology to bring a better experience to our users.