Short Description:
UPS2000-A series with a capacity ranging from 1kVA to 3kVA is an online double conversion power system that delivers continuous, high-quality AC Power. It's really a perfect power protection solution for small power scenarios. 


Scenarios
• Small and medium enterprises, large enterprise branch offices, bank branches and other small data centers.
• Networks, communications systems, automatic control systems and other precision equipment.
• Family, office.
Features
Reliable
• Wide input voltage range to minimize battery use
• Online double conversion power system provides continuous, high quality AC Power.
Efficient
• Efficiency up to 90%, reduce energy consumption, green and energy saving.
• Ultra small volume, compared to the traditional UPS system to save space
Simple
• LCD screen supports real-time monitoring and convenient operation.
• Built-in battery, easy to use.
• Enables quick and easy configuration of the UPS.
• NetEco network manager, supporting centralized management to all.
Specifications
| Rated capacity (kVA/kW) Rated capacity (kVA/kW) | 1kVA/0.8kW 2kva/1.6kW 3kVA/2.4kW | |
| Input Output | 1-in: 1-out | |
| Mains Input | Input Wiring | L+N+PE |
| Rated Voltage | 220/230/240VAC | |
| Input Vbltage Range | 110-300WC | |
| Input Frequency Range | 40-70HZ | |
| Input Power Factor | 0.99 | |
| Bypass Input | Input Rated Voltage | 22(y23(V240VAC |
| Input VoItage Range | 174-264WC | |
| Input Frequency Range | 47-53Hz/57-63Hz | |
| Battery | Standard | 24VDC 48VDC 72VDC |
| Long Backup | 36VDC 72VDC 96VDC | |
| Standard Backup Time 9ng Backup | >5 minutes @ 80% loadDepending on the capacity of external batteries | |
| Output | Output Wiring | L+N+PE |
| Output Connections | 4XIECC13 6XIECC13 6XIECC13 + 1 XIECC19 | |
| Rated Voltage | 22(V23(V240VAC±1% | |
| Output Frequency | Tracking the bypass input (Normal mode); 5O/6OHz ± 0.05% | |
| Output Power Factor | 0.8 | |
| Waveform | Sinewag THDv< 3% | |
| System Efficiency | 88% ^||89% 90% | |
| Overload Capacity | si 10% overload for 10 minutes;130% overload for 1 minute^l 50% owrload for 3 seconds | |
| Operating Temperature | 0to40°C | |
| Environment | Storage Temperature | -40 to +70°C (battery: -20 to 440°O |
| Relative Humidity | 0%-95% RH (no condensation) | |
| Operating Altitude | 0-1000m. Above 1000m, derating rate based on EN/IEC 62040-3 | |
| Audible Noise | <50dB | |
| Others | StandardDxWxH(mm) 9ng Backup | 282x145 x 220 397x145 x 220 421 x 190 x 318 |
| 282 x 145 x 220 397 x 145 x 220 397 x 145 x 220 | ||
| Standard Weight (kg) Long Backup | 9.9 173 26.7 | |
| 4.8 7.6 82 | ||
| Certifications | EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REYH, WEEE, etc. | |
| Communications | USB&RS232 (optional RS485/Dfy contacVSNMP) | |
Models for 1-3KVA UPS
| Model | Descriptions | Battery Request (12V) | Install Way |
| UPS2000-A-1KTTS | Built-in battery, backup time 4 mins on full load | Tower Mounted | |
| UPS2000-A-1KTTL | Without built-in battery,shall equip with external battery | 3PCS | |
| UPS2000-A-2KTTS | Built-in battery, backup time 4 mins on full load | ||
| UPS2000-A-2KTTL | Without built-in battery,shall equip with external battery | 6PCS | |
| UPS2000-A-3KTTS | Built-in battery, backup time 4 mins on full load | ||
| UPS2000-A-3KTTL | Without built-in battery,shall equip with external battery | 8PCS | |
| UPS2000-A-6KTTL-S | Without built-in battery,shall equip with external battery | 16-20 PCS | |
| UPS2000-A-10KTTL-S | Without built-in battery,shall equip with external battery | 16-20PCS |