I. a. C. M with Polystyrene Insulation Outdoor Load Break Isolating Switch

Price $1100.00 Compare
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 309 people viewed
Quantity
+-
 

Ningbo Jecsany Electrical Equipment Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
JS-IACM-24KV-100A
High-voltage
Three-column Disconnector
Outdoor High-voltage
Manual
Not Grounding
Vertical Rotary Type
Three Pole
Un Grounded
Three
Turn the Horizontal
Single Throw-in
Manual
ISO, ISO9001
According to Customer
Jecsany
Wooden Carten
HRH-B/11F
China
8535309090
Product Description

Product Description

IACM with polystyrene insulation  Outdoor Load Break Isolate Switch

General

 LBIS Type outdoor on load break switch disconnector contained in this list are destined to switch stub lines and ring main lines or transformers (It can be equipped with MV HRC fuse links as short circuit protection fuction) or for switching under on load conditions. This disconnector complies with IEC/IEEE and DVE-recommendation standards especially comply with DIN VDE 0670 part 3 and IEC 60265, IEC 129.

 Features

 All steels are made of either in stainless steel or hot-dip galvanized steel.

 1. Solid and stable base frame.
 2. main contact with ice protection.
 3. Polymer insulators or alternatively in porcelain.
 4. Minimal sag for the line-connection between two fixed terminals.
 5. Completely maintence antirust Aluminium alloy Arc chamber.
 6. Switching-off procedure without external arc.
 7. Short circuit making capacity under specific conditions possible
 8. Fixing on the supporting structure either by clamping(free setting) or screwing (holes in the   base frame)
 9. Easy on-site installation and setting.

 10. High reliabilty up to 1000 cycles (depending on the running current).

 11. All contacts are either sliver or tin-plated.
 12. Practically maintance-free.

 Environmental   Conditions

 Ambient Temperature: -40ºC - +50ºC 

 Altitude: 2500m

 Frequency: 50Hz / 60Hz

 Maximum Wind Speed: 35m/s

 
DesignationMechanical characteristics

JS-IACM-24KV-50A

A
(mm)

B
(mm)

C
(mm)

D
(mm)
Creepage(HTV Insulator)
(mm)
Number of skirts
(HTV Insulator)
Approximate weight
(Kg)
ReferenceOn isolatedSpecialOn isolatedSpecialOn isolatedSpecial
On isolatedSpecial
695

695

650

740

884

1020

9

11

80

81
1145011412
Rated current in continuous service  (A)Rated breaking capacity  (A)Rated short-term admissible current (rms) (kA) (1s)Rated closing capacity on short circuit  ( Crete)(kA)Tension assigned
(kV)
Dry lightning impulsewithstand voltage(kV)Frequency
(Hz)
4005012.531.52412550
DesignationMechanical characteristics

JS-IACM-24KV-100A

A
(mm)

B
(mm)

C
(mm)

D
(mm)

H
(mm)
Creepage(HTV Insulator)(mm)Number of skirts (HTV insulator)Approximate weight(Kg)
ReferenceOn isolatedSpecialOn isolatedSpecialOn isolatedSpecial
On isolatedSpecial
695

695

650

740

640

884

1020

9

11

87

88
1484214840
Rated current in continuous service  (A)Rated breaking capacity  (A)Rated short-term admissible current (rms) (kA) (1s)Rated closing capacity on short circuit  ( Crete)(kA)Tension assigned
(kV)
Dry lightning impulsewithstand voltage(kV)Frequency
(Hz)
40010012.531.52412550








Isolating Switch 

An electrical device for the reliable disconnection of certain sections of a high-voltage electrical network when there is no current in them. The use of isolating switches (either alone or in combination with high-speed short-circuiting devices) makes it possible to simplify the arrangement of switching points and transformer substations and to eliminate expensive high-voltage circuit breakers.

 

In the case of damage to certain sections of a network, the circuit breakers operate first, and then the isolating switches automatically disconnect the damaged section, after which the circuit breakers close again and restore electric power to the rest of the consumers on the network. Isolating switches are also used to disconnect and reconnect unloaded transformers and sections of power lines during operation. An isolate switch must provide a reliable connection in case of a random occurrence of a short circuit in the network. An important characteristic of an isolating switch is a short operate time, particularly the disconnect time, which must not exceed 0.1 sec.

More Products

 

 

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$28.00 10 Pieces(MOQ)

China 10kv Transmission Composite Polymer Line Post Insulators

Ningbo Jecsany Electrical Equipment Co., Ltd.
$256.00 10 Pieces(MOQ)

Durable Easy Pulled Fiberglass Extension Ladder

Ningbo Jecsany Electrical Equipment Co., Ltd.
$6300.00 1 Piece(MOQ)

High Voltage Zw7-40.5 Vacuum Circuit Breaker

Ningbo Jecsany Electrical Equipment Co., Ltd.
$45.00 100 Pieces(MOQ)

Outdoor Type High Voltage Polymer Electrical Expulsion Dropout Fuse Cutout

Ningbo Jecsany Electrical Equipment Co., Ltd.
$1800.00 1 Piece(MOQ)

22kv 630A Outdoor Pole Mounted Sf6 Gas Insulated Load Break Switch /33kv Primary Lbs Breaker Sm6 Load Break Switch

Wenzhou Mingzhe Electric Co., Ltd.
$123.00 10 Pieces(MOQ)

Siyan 1600A 3p Disconnector Electric Disconnector DC Generator Transfer Switch

Zhejiang Siyan Electric Technology Co., Ltd
$30.00 1 Piece(MOQ)

Vr-32 Low Voltage Three-Phase Industrial Disconnector

Hong Qi Group Wenzhou Transformer Co., Ltd.
$50.00 10 pieces(MOQ)

12-36kv Rh-B Outdoor AC High Voltage Disconnecting Switch

Xiya Electric Equipment Co., Ltd.
$9.80 10 Pieces(MOQ)

Blue Sea 3000 32V 600A Single Circuit on-off Battery Switch

Suzhou Electric Solution Co., Ltd.
$15.00 1 Piece(MOQ)

Dead End Clamp for ACSR Conductor Compression Type

ORIENT ELECTRIC INTERNATIONAL GROUP LIMITED