IEC Standard Low Voltage 0.6/1kv XLPE Insulated Steel Tape Armored Copper Aluminum Conductor PVC Sheathed Electric Wire Power Cable for Construction

Price $60.00 Compare
Min Order 1000 Meters
Availability In Stock
Shipping From Henan, China
Popularity 352 people viewed
Quantity
+-
 

Henan Eternal Trading Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
YJV22 YJLV22
Overhead, Underground
PVC
XLPE
Round Wire
CCC
Qif
1, 2, 3, 4, 3+1, 5, 4+1, 3+2
1.5~800mm²
Zryjv22, Nhyjv22
100% Qualified
Steel Tape
Wooden Drum
Black, Red, Green, Orange
QIF
Standard Export Packing
2c
China
854449210
Product Description
Product Description

Structure

Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with IEC 60228
Insulation : 90°C cross linked XLPE insulation complying with IEC 60502-1
Interlining: PVC type ST2 to IEC 60502, black
Armoring: STA(Steel-Tape Armoring)
Sheath : PVC type ST2 to IEC 60502, black
 

Detailed Product Description

Conductor:Class 2
Insulation:XLPE
Sheath: PVC
Cable Speciification: Fire Resistant
Marking: Embossing Or Printing
Sheath Color: Black Or Red

Standards:

International: IEC 60502, IEC 60228, IEC 60332, IEC 60754
China: GB/T 12706.1-2008, GB/T 19666-2005
Other standards such as BS,VDE and ICEA upon request
 

Applications

Laying in room ,tunnel ,cable trench ,and pipes.
 

Technical data

Rated voltage: 0.6/1kV
Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.
Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables
15 x cable O.D for single-core armoured cables
15 x cable O.D for multi-core non-armoured cables
12 x cable O.D for multi-core armoured cables

Detailed Photos

 
Product Parameters

 

Nom. Cross-section of Conductor mm2Strands No./Dia. Of ConductorInsulation Thickness
mm
Steel Tape Thickness
mm
Sheath Thickness
mm
Approx. O.D.
mm
Approx. Weight
kg/km
Max. D.C Resistance of Conductor
 (20 ºC)
Testing Voltage A.CCurrent Rating
In air (A)In soil(A)
1×107/1.330.70.21.811.82651.833.57794
1×167/1.670.70.21.812.83381.153.5100120
1×257/2.100.90.21.814.54580.7273.5130155
1×357/2.480.90.21.815.65710.5243.5160185
1×5010/2.5610.21.816.87120.3873.5195220
1×7014/2.561.10.21.818.79400.2683.5245270
1×9519/2.561.10.21.820.312090.1933.5300320
1×12024/2.561.20.21.82214650.1533.5349365
1×15030/2.561.40.21.823.817570.1243.5400410
1×18537/2.561.60.21.825.921570.09913.5465465
1×24048/2.581.70.21.828.327320.07543.5550540
1×30060/2.581.80.21.930.933440.06013.5635610
1×40060/2.9320.2234.442600.0473.5745695
1×50060/3.332.20.52.239.656730.03663.5860780
1×63060/3.762.40.52.34471330.02833.5990880
 
Nom. Cross-section of Conductor mm2Strands No./Dia. Of ConductorInsulation Thickness
mm
Steel Tape Thickness
mm
Sheath Thickness
mm
Approx. O.D.
mm
Approx. Weight
kg/km
Max. D.C Resistance of Conductor (20 ºC)Testing Voltage A.CCurrent Rating
In air (A)In soil(A)
2×1.51/1.380.70.21.812.323012.13.52031
2×2.51/1.760.70.21.813.12667.563.52741
2×41/2.230.70.21.8143164.613.53553
2×61/2.740.70.21.8153783.083.54566
2×107/1.330.70.21.817.55161.833.56390
2×167/1.670.70.21.819.56721.153.584117
2×257/2.100.90.21.822.99370.7273.5113151
2×357/2.480.90.21.825.211810.5243.5139181
2×5010/2.5610.21.821.812810.3873.5161210
2×7014/2.561.10.21.924.817340.2683.5204257
2×9519/2.561.10.2227.522780.1933.5252310
2×12024/2.561.20.52.231.330950.1533.5291351
2×15030/2.561.40.52.334.537300.1243.5333393
2×18537/2.561.60.52.538.246180.09913.5385445
2×24048/2.561.70.52.642.258320.07543.5457516
2×30060/2.561.80.52.846.371420.06013.5527583
 
 
Nom. Cross-section of Conductor mm2Strands No./Dia. Of ConductorInsulation Thickness
mm
Steel Tape Thickness
mm
Sheath Thickness
mm
Approx. O.D.
mm
Approx. Weight
kg/km
Max. D.C Resistance of Conductor (20 ºC)Testing Voltage A.CCurrent Rating
In air (A)In soil(A)
3×1.51/1.380.70.21.812.725612.13.52031
3×2.51/1.760.70.21.813.53027.563.52741
3×41/2.230.70.21.814.63674.613.53553
3×61/2.740.70.21.815.74493.083.54566
3×107/1.330.70.21.818.46271.833.56390
3×167/1.670.70.21.820.58381.153.584117
3×257/2.100.90.21.824.211910.7273.5113151
3×357/2.480.90.21.826.615280.5243.5139181
3×5010/2.5610.21.925.518140.3873.5161210
3×7014/2.561.10.222924740.2683.5204257
3×9519/2.561.10.52.133.535980.1933.5252310
3×12024/2.561.20.52.336.743860.1533.5291351
3×15030/2.561.40.52.440.753320.1243.5333393
3×18537/2.561.60.52.544.665620.09913.5385445
3×24048/2.561.70.52.850.284140.07543.5457516
3×30060/2.561.80.52.954.9103060.06013.5527583
 
Nom. Cross-section of Conductor mm2Strands No./Dia. Of ConductorInsulation Thickness
mm
Steel Tape Thickness
mm
Sheath Thickness
mm
Approx. O.D.
mm
Approx. Weight
kg/km
Max. D.C Resistance of Conductor (20 ºC)Testing Voltage A.CCurrent Rating
In air (A)In soil(A)
4×1.51/1.380.70.21.813.529112.13.52031
4×2.51/1.760.70.21.814.43487.563.52741
4×41/2.230.70.21.815.54304.613.53553
4×61/2.740.70.21.816.75343.083.54566
4×107/1.330.70.21.819.87581.833.56390
4×167/1.670.70.21.822.210271.153.584117
4×257/2.100.90.21.826.314790.7273.5113151
4×357/2.480.90.21.829.119140.5243.5139181
4×5010/2.5610.2228.423340.3873.5161210
4×7014/2.561.10.52.133.635180.2683.5204257
4×9519/2.561.10.52.337.946380.1933.5252310
4×12024/2.561.20.52.441.857010.1533.5291351
4×15030/2.561.40.52.64669120.1243.5333393
4×18537/2.561.60.52.75185620.09913.5385445
4×24048/2.561.70.5357.7110520.07543.5457516
4×30060/2.561.80.53.162.7134790.06013.5527583
 
Nom. Cross-section of Conductor mm2Strands No./Dia. Of ConductorInsulation Thickness
mm
Steel Tape Thickness
mm
Sheath Thickness
mm
Approx. O.D.
mm
Approx. Weight
kg/km
Max. D.C Resistance of Conductor (20 ºC)Testing Voltage A.CCurrent Rating
In air (A)In soil(A)
5×1.51/1.380.70.21.814.332812.13.52031
5×2.51/1.760.70.21.815.33977.563.52741
5×41/2.230.70.21.816.64974.613.53553
5×61/2.740.70.21.8186233.083.54566
5×107/1.330.70.21.821.48951.833.56390
5×167/1.670.70.21.824.112251.153.584117
5×257/2.100.90.21.828.717800.7273.5113151
5×357/2.480.90.21.931.923290.5243.5139181
5×5019/1.8610.22.131.928790.3873.5161210
5×7014/2.561.10.52.237.843270.2683.5204257
5×9519/2.561.10.52.442.857400.1933.5252310
5×12024/2.561.20.52.546.870270.1533.5291351
5×15030/2.561.40.52.752.185910.1243.5333393
5×18537/2.561.60.52.957.5106360.09913.5385445
5×24048/2.561.70.53.264.5136510.07543.5457516
5×30060/2.561.80.53.471167640.06013.5527583
 
Nom. Cross-section of Conductor mm2Strands No./Dia. Of ConductorInsulation Thickness
mm
Steel Tape Thickness
mm
Sheath Thickness
mm
Approx. O.D.
mm
Approx. Weight
kg/km
Max. D.C Resistance of Conductor (20 ºC)Testing Voltage A.CCurrent Rating
In air (A)In soil(A)
3×2.5+1×1.51/1.760.70.21.814.13347.563.52741
3×4+1×2.51/2.230.70.21.815.24104.613.53553
3×6+1×41/2.740.70.21.816.45083.083.54566
3×10+1×67/1.330.70.21.8197011.833.56390
3×16+1×107/1.670.70.21.821.69591.153.584117
3×25+1×167/2.100.90.21.825.313650.7273.5113151
3×35+1×167/2.480.90.21.827.416890.5243.5139181
3×50+1×2510/2.5610.21.927.921150.3873.5161210
3×70+1×3514/2.561.10.2232.128960.2683.5204257
3×95+1×5019/2.561.10.52.237.442130.1933.5252310
3×120+1×7024/2.561.20.52.341.452510.1533.5291351
3×150+1×7030/2.561.40.52.44561750.1243.5333393
3×185+1×9537/2.561.60.52.65077310.09913.5385445
3×240+1×12048/2.561.70.52.85698570.07543.5457516
3×300+1×15060/2.561.80.5361.3120420.06013.5527583
3×2.5+2×1.51/1.760.70.21.814.93697.563.52741
3×4+2×2.51/2.230.70.21.816.14574.613.53553
3×6+2×41/2.740.70.21.817.45733.083.54566
3×10+2×67/1.330.70.21.8207851.833.56390
3×16+2×107/1.670.70.21.82310921.153.584117
3×25+2×167/2.100.90.21.826.815560.7273.5113151
3×35+2×167/2.480.90.21.828.718740.5243.5139181
3×50+2×2510/2.5610.2229.123840.3873.5161210
3×70+2×3514/2.561.10.52.134.435830.2683.5204257
3×95+2×5019/2.561.10.52.338.546920.1933.5252310
3×120+2×7024/2.561.20.52.442.559090.1533.5291351
3×150+2×7030/2.561.40.52.546.868890.1243.5333393
3×185+2×9537/2.561.60.52.752.587440.09913.5385445
3×240+2×12048/2.561.70.52.958.5110680.07543.5457516
3×300+2×15060/2.561.80.53.164.5135510.06013.5527583
 
Nom. Cross-section of Conductor mm2Strands No./Dia. Of ConductorInsulation Thickness
mm
Steel Tape Thickness
mm
Sheath Thickness
mm
Approx. O.D.
mm
Approx. Weight
kg/km
Max. D.C Resistance of Conductor (20 ºC)Testing Voltage A.CCurrent Rating
In air (A)In soil(A)
4×2.5+1×1.51/1.760.70.21.815.13837.563.52741
4×4+1×2.51/2.230.70.21.816.44774.613.53553
4×6+1×41/2.740.70.21.817.75983.083.54566
4×10+1×67/1.330.70.21.820.78391.833.56390
4×16+1×107/1.670.70.21.823.511591.153.584117
4×25+1×167/2.100.90.21.827.716670.7273.5113151
4×35+1×167/2.480.90.21.930.421070.5243.5139181
4×50+1×2510/2.5610.2229.525900.3873.5161210
4×70+1×3514/2.561.10.52.23539000.2683.5204257
4×95+1×5019/2.561.10.52.339.351440.1933.5252310
4×120+1×7024/2.561.20.52.543.263860.1533.5291351
4×150+1×7030/2.561.40.52.648.376830.1243.5333393
4×185+1×9537/2.561.60.52.853.295660.09913.5385445
4×240+1×12048/2.561.70.5359.7122190.07543.5457516
4×300+1×15060/2.561.80.53.365.6149850.06013.5527583

 

Related Type

TypeDescriptionNo. of coresNominal Cross
Section of Conductor
YJV22Copper conductor XLPE insulation Steel Tape Armoured PVC outer sheath Power Cable1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~630mm²
YJV23Copper conductor XLPE insulation Steel Tape Armoured PE outer sheath Power Cable1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~630mm²
ZA-YJV22
ZB-YJV22
ZC-YJV22
Copper conductor XLPE insulation Steel Tape Armoured flame-retardant Power Cable1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~630mm²
WDZA-YJY23
WDZB-YJY23
WDZC-YJY23
Copper conductor XLPE insulation Steel Tape Armoured Low Smoke Halogen Free Or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~630mm²
NH-YJV22Copper conductor XLPE insulation Steel Tape Armoured fire-resistant Power Cable1, 2, 3, 4, 3+1,
5, 4+1, 3+2
1.5~630mm²
 
Workshop Corner

Test Equipment

Packaging & Shipping

 

FAQ

How can I get some samples?

We provide free sample and will courier to you by DHL, FEDEX, UPS, TNT, etc. swiftly according to your requirements.


How do you control the quality?
QC department will control the quality during the full production process.
Inspector will inspect each item according to the order, inspection report will transfer to you before loading.
Any third party inspection will be accepted during the production or before loading, such as SGS, BV, etc.  
After-sale dept will follow the order and pay high attention on the feedback from your side after all the products delivered. Any quality problem, we will arrange the technical personnel to solve and bear the corresponding customer losses..

What if the cable we need have some differences on specifications from yours?
Any differences, we can design and produce according to your requests.


What's the package of the goods?
Usually wooden or steel drum or coil, or according to your requirement

What's the lead time?
Usually 10-30 working days.

Welcome your inquiry and email soon......

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$12.00 1 Meter(MOQ)

Aluminum Alloy Wiring Low Voltage High Quality AAC Aluminum Cable

Henan Eternal Trading Co., Ltd.
$6.00 500 kg(MOQ)

IEC 60317 Enameled Insulated Round Aluminum or Copper Magnet Wire Winding Wire

Henan Eternal Trading Co., Ltd.
$20.00 1000 Meters(MOQ)

Wholesale Good Quality Cu/Al//XLPE/Swa/PVC Copper Aluminium Conductor Steel Wire Armoured Low Voltage Yjv32 Yjlv32 Electrical Wire Power Cable

Henan Eternal Trading Co., Ltd.
$9.00 2 Meters(MOQ)

3 Core Low Voltage Cable XLPE Insulation Copper Conductor Underground Power Cables

Henan Eternal Trading Co., Ltd.
$0.50 100 Meters(MOQ)

UL Cable Type Nm-B/UF-B Wire Nonmetallic-Sheathed Cable

Zhejiang Yuantong Wire & Cable Manufacturing Co., Ltd.
$1.00 1000 Meters(MOQ)

RF Coaxial Cable Rg178 CE RoHS Approved Factory Price FEP Jacket

Hangzhou Fuyang Tangyi Industrial Co., Ltd.
$50.00 500 Meters(MOQ)

12/20kv Cu/XLPE/Cts/PVC/Awa/PVC 240 300 400 500 630 Sq mm Single Core Cable

Chunbin Cable Group Co., Ltd.
$1.00 5000 Meters(MOQ)

Twin Parallel Mellizo Frsoted Transparent PVC Speaker Audio Electric Cable 0.75 Sqmm 1.0 Sqmm 1.5 Sqmm 2.5sqmm

Jiaxing Weda Electronic Co., Ltd
$0.10 5000 Meters(MOQ)

Ho5VV-F 2core 3core 4core Copper/CCA Conductor PVC Insulated Sheath Flexible Wire

Jiaxing Huahao Cable Co., Ltd.
$1.50 100 Meters(MOQ)

AWG 20 Thermocouple Cable Type K with Insolation PTFE / PVC / PFA

Ohmalloy Material Co., Ltd.