1) Manufacturing execution standard (technical conditions): refer to GB/T 10586-2006 Technical Conditions of Damp Heat Test Chamber
2) Guiding principle: IEC 60068-3-5 Environmental test of electrical and electronic products - performance confirmation of temperature test chamber
3) GB 5226.1-2002/IEC 60204-1:2000 Safety of Machinery - Electrical and Mechanical Equipment - Part 1: General Specifications
4) Meet the ICH2003Q1A (2) guidelines and the GMP 2010 version of the Chinese Pharmacopoeia stability test conditions:
1. Accelerated test: 40ºC±2ºC/75%RH±5%RH
2. Intermediate conditions: 30ºC±2ºC/65%RH±5%RH
3. Long-term test: 25ºC±2ºC/60%RH±5%RH or 30ºC±2ºC/65%RH±5%RH
| Internal size | 1000w*1000D*1000Hmm or customized |
| External size | 1550w*1600D*1900Hmm |
| Temp range | 0--100ºC |
| Temperature resolution | 0.1ºC |
| Temperature uniformity | ≤±2ºC |
| Temperature deviation | ≤±2ºC |
| Cooling | 0.7-1.2ºC/min non-linear no-load |
| Heating temperature | 3-5ºC/min non-linear no-load |
| Humidity range | 20%R.H~98%R.H |
| Humidity deviation | ≤±2%R.H (humidity>75%RH) ≤±5%R.H (humidity≤75%RH |
| Humidity fluctuation | ±1%R.H |
| Humidity resolution | 0.1%R.H |
| UV irradiance | 80-100μw/cm² |
| UV spectral range | 320~400 nm |
| Illumination range (Lux) | 0~10000 |
| Illumination deviation (Lux) | ±500 |
| Power | 9KW |
| Power supply | 380V±10%V; 50Hz |
| External material | brushed stainless steel |
| Internal material | SUS#304 stainless steel |
| Safety protection | overload protection, compressor overheating, overcurrent, overpressure, heating and dry burning, overtemperature alarm system in the box |
| Item name: | Material | Qty |
| Compressor | Tecumseh (France) | 2sets |
| Condenser | Fin type with inlet cooling fan (Kuweili) | 1set |
| Evaporator | Customized (Zhongli) | 1set |
| Expansion valve | Danfoss/Honeywell | 2pcs |
| Solenoid valve | FDF (Sanhua group) | 2pcs |
| Solenoid valve | FDF(Sanhua group ) | 2pcs |
| Pressure controller | Danfoss | 1pc |
| Oil separator | S-4004 | 1pc |
| Filter | EMERSON | 1pc |
| Refrigerant:R404A | Honeywell | lot |
| Copper pipes | Taishun | 1set |
| Temperature and humidity controller | TEMI880 touch screen | 1set |
| Over temperature protection instrument; | EGO(CHNT) | 1pc |
| Temperature Sensor; | Pt100 | 2pcs |
| Humidity Sensor | Pt100 | 1pc |
| Contactor | CJX2(CHNT) | 2pcs |
| Solid state relay | SSR(Yangming) | 3pcs |
| Time delay relay | ANV(Yangming) | 2pc |
| Intermediate relay | Omron | lot |
| Heating Pipe | Customized | 2sets |
| Switching power supply (leakage protection) | DZ47LE(CHNT) | 1set |
| Transformer | Customized | 1pcs |
| Control switch panel | Customized | 1set |
| Warning light | Customized | 1set |
| Heating protection | Customized | 1set |







Audited Supplier