Model | Power(Kw) | Free Air Delivery(m³/min) | Cooling water outlet/inlet diamater | Quantity of cooling water(T/H) | Quantity of lubricating water(L) | Weight(kg) | Size(mm)(L*W*H) | Air outlet | ||
0.8Mpa | 1.0MPa | 1.25MPa | ||||||||
MQE11A/W | 11 | 0.54~1.72 | 0.45~1.42 | 0.35~1.10 | 1″ | 2.5 | 26 | 400 | 1200*755*1130 | 3/4″ |
MQE15A/W | 15 | 0.75~2.43 | 0.65~2.17 | 0.60~1.80 | 1″ | 3.5 | 26 | 440 | 1200*755*1130 | 3/4″ |
MQE18A/W | 18.5 | 0.9~3.13 | 0.9~2.82 | 0.60~2.05 | 1″ | 4 | 30 | 640 | 1400*900*1270 | 1″ |
MQE22A/W | 22 | 1.10~3.70 | 0.97~3.21 | 0.85~2.78 | 1″ | 5 | 30 | 640 | 1400*900*1270 | 1″ |
MQE30A/W | 30 | 1.55~5.20 | 1.25~4.43 | 1.10~3.63 | 1 1/4″ | 7 | 40 | 760 | 1400*950*1380/1500*1080*1300(w) | 1 1/4″ |
MQE37A/W | 37 | 1.91~6.50 | 1.60~5.33 | 1.42~4.77 | 1 1/4″ | 9 | 40 | 880 | 1580*1000*1475/1500*1080*1300(w) | 1 1/4″ |
MQE45A/W | 45 | 2.5~8.30 | 1.91~6.30 | 1.70~5.56 | 2″ | 10 | 90 | 1490 | 1800*1300*1680/1800*1300*1750(w) | 2″ |
MQE55A/W | 55 | 3.00~10.3 | 2.60~8.55 | 2.30~7.67 | 2″ | 12 | 100 | 1570 | 2050*1360*1688/1800*1300*1750(w) | 2″ |
MQE75A/W | 75 | 3.95~13.00 | 3.40~11.50 | 3.00~9.70 | 2″ | 18 | 100 | 1750 | 2180*1350*1680/1800*1300*1750(w) | 2″ |
MQE90A/W | 90 | 5.00~16.60 | 4.30~14.66 | 3.72~12.60 | 2″ | 20 | 120 | 2450 | 2550*1500*1800/2200*1550*1800(w) | 2 1/2″ |
MQE110A/W | 110 | 6.00~20.20 | 5.00~16.66 | 4.65~15.56 | 2″ | 24 | 120 | 2580 | 2550*1500*1800/2200*1550*1800(w) | 2 1/2″ |
MQE132A/W | 132 | 6.75~22.52 | 6.00~19.97 | 5.07~16.90 | 2″ | 30 | 120 | 2700 | 2200*1550*1800 | 2 1/2″ |
MQE160A/W | 160 | 8.5~28.11 | 7.60~25.45 | 6.70~22.52 | 3″ | 35 | 160 | 3900 | 2700*1830*1850 | DN80 |
MQE185A/W | 185 | 10~33.97 | 8.72~29.00 | 7.75~25.21 | 3″ | 38 | 160 | 4050 | 2700*1830*1850 | DN80 |
MQE200A/W | 200 | 11.2~36.75 | 9.68~32.78 | 9.20~29.24 | 4″ | 42 | 200 | 4200 | 2700*1830*1850 | DN100 |
MQE220A/W | 220 | 12.2~39.67 | 11.2~36.75 | 9.0~29.63 | 4″ | 47 | 200 | 4400 | 2700*1830*1850 | DN100 |
MQE250A/W | 250 | 13.5~45.00 | 12.3~39.67 | 10.2~33.97 | 4″ | 53 | 200 | 4800 | 2700*1830*1850 | DN100 |








Operation Instructions:
A:Before Operation:
- Confirm the voltage of the power supply and the power indicator light is lit.
- Please open the leak valve of the oil & gas tank, drain the condensed water and immediately close the leak valve when oil leaks out.
- Please check the oil level and keep it between indicator oil level.
- Water cooled system , confirm that cooling water supply is normal.
- When generator driving the belt, please check the belt tension correctly, not too loose or too tight.
- Main power switch in.
- Press the start button to turn on the motor, working indicator light is on.
- Check the discharge pressure gauge and lubricating oil pressure gauge are in correct indication.
Please keep the exhaust temperature between 75ºC-95ºC to avoid condensation and precipitation and emulsify the oil.
D:Stop
- Press the "off" button, about 10-15 seconds later, the delay electromagnetic valve acts, and the compressor stops running.
- Turn off the power.
- Don't use the emergency stop button in case of non emergency.
- For initial start-up and after motor maintenance, determine the running direction of the press (as indicated by the arrow).
- Do not mix different brand of river lubricating oil.
- Change the consumables, lubricating oil and detail operation method, please refer the instruction manual.