model | 5KV | 10KV | 20KV | 50KV | 100KV | 150KV |
input voltage | AC220V 50Hz | |||||
input voltage | AC: 0-5kV; DC: 0-5kV | AC: 0-10kV; DC: 0-10kV | AC: 0-20kV; DC: 0-20kV | AC: 0-50kV; DC: 0-50kV | AC: 0-100kV; DC: 0-100kV | AC: 0-150kV; DC: 0-150kV |
output power | 0.5kVA | 1kVA | 3kVA | 5kVA | 10kVA | 15kVA |
measuring range | AC: 0.05-5kV; DC: 0-5kV | AC: 0.5-10kV; DC: 0.5-10kV | AC: 1-20kV; DC: 1-20kV | AC: 1-50kV; DC: 1-50kV | AC1-100kV; DC1-100kV | AC1~150kV; DC1-150kV |
measurement error | ≤ 2% | |||||
pressure rate | 0.025kV/s-0.5/s | 0.05kV/s~1kV/s | 0.1kV/s-2kV/s | 0.20kV/s-5kV/s | 0.02kV/s-10kV/s | 1kV/s-10kV/s |
Withstand voltage time | 0-4H (no load) | |||||
Leakage current | Can be freely set by computer software | |||||
source | AC 220V ± 10% single-phase AC voltage and 50Hz ± 1% frequency | |||||
Test environment | Temperature: 15-30 ºC, relative humidity: 30-65%, capable of stable operation. | |||||
Overall dimensions | long × wide × Height: 1000 × 1000 × 1400 mm | |||||
Equipment self weight | 150kg | 300kg | ||||
Grounding requirements | The instrument needs to be grounded separately, in accordance with national standards, and the metal rod should be buried at least 1.5 meters underground |
1. The device operates and controls the touch screen.
2. If curve analysis is required, a computer can be equipped to record data and curves only, without equipment control, so that the tester can avoid alternate operation between the computer and equipment, which is more humanized.
3. The equipment has the test parameter memory function. The same test conditions do not need to be set for each test, and the last test setting parameters will still be memorized after power failure.
4. The test interface is simple and clear, and it is equipped with schematic curve description. Different parameters and curve trends make it easy to understand.
5. The control panel is simple, with clear function annotation and simple operation.
6. It can record and display 10 test records at the same time to facilitate the comparative analysis of test data. Any group of data that is not ideal can be discarded at any time.
7. The equipment test interface adopts the real-time display mode, which is more convenient for viewing the test process.
8. The equipment has a safety warning prompt. The test cannot be started without closing the door of the test box, and a warning will pop up. The warning will pop up when the test is full (that is, the high-voltage transformer has no output). If the door is opened during the test, the test will automatically end.
9. The equipment is equipped with three color alarm. (Optional)
KDZD5550 series voltage breakdown tester: 1 set
Input/output connection line: 1 set
Equipment grounding wire: 1 piece
Test electrodes: 2 pairs
Product manual: 1 copy
Product certificate: 1 copy