Profile Certified by SGS/BV
FLN36-12(D)
High-voltage
Composed of Switch Room, Fuse Room, Operation Mech
Indoor High-voltage
Electric
Grounding
Sf6 Gas Insulated Switch Protection System
Two Positions and Three Positions
Composed of Switch Room, Fuse Room, Operation Mech
Two Positions Has No Earthing, Three Positions Has
Plug-In
Double-Throw Type
Sf6 Full Closed
Electric and Manual
ISO, GS, RoHS, CE, IS9001, ISO9001, ISO9002, ISO2000
Mingzhe
12kv 24kv 36kv
630A
Earthing, Fuse, Microcomputer(for 35kv)
Sf6 Load Break Switch Lbs
25ka
Epoxy Resin
Sf6 Insulated Load Break Switch
Load Breaker Switch(Lbs)
MINGZHE
Carton and Pallet
430*780*510mm
China
8537209000
Product Description
 
Product Description
 

FL(R)N36-12(D) Load switches and combiners (hereinafter referred to as "load switches" and "combiners") are suitable for three-phase ac power systems of 10kV and 50Hz
This product as industrial and mining enterprises, high-rise buildings, residential quarters, pre-installed type substation, for the breaking, closing load current, the fault current, control and protection circuit and the power distribution transformer

1.normal operating conditions

a)Ambient air temperature is not more than 40 ºC, and at 24 h closed to the average no more than 35 ºC. Minimum ambient air temperature 25 ºC.
b)The effects of sunlight can be ignored
c)No more than 3000m above sea level.
d)Ambient air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt fog. If the user does not have special requirements, the manufacturer may consider that these situations do not exist.e)The humidity conditions are as follows:
--The average relative humidity measured within 24h is no more than 95%.
--The mean value of water vapor pressure measured within 24h shall not exceed 2.2kPa.
--The average monthly relative humidity should not exceed 90%.
--The average monthly water vapor pressure does not exceed 1.8kpa. In such conditions appear condensation occasionally.
f) The vibration or ground motion from the outside of the switching equipment and the control equipment has no obvious relationship with the normal operation mode of the equipment. If the user has no special requirements, the manufacturer may not consider these situations.

GB 3804-2004        3.6KV~40.5KVHigh voltage ac load switch
GB 16926-2009       High voltage ac load switch fuse combination electrical appliance
GB 11023-1989       Test guide for fln36 gas seal of high pressure switching equipment
GB 1985-2004        High voltage ac isolation switch and ground switch
GB/T 11022-2011 Common technical requirements for high voltage switching equipment and control equipment standards

Product Parameters

 

No.
  •    Description
UnitData
FLN36-12FLN36-12D
1
  • Rated Voltage
kV12
2
  • Rated Current
A630125
3Load switch rated short - term withstand current/durationkA/s20/3
Ground switch rated short - term withstand current/durationkA/s20/2
4Rated peak withstand current and short circuit closing currentkA50125(Expect)
5Rated active load switching currentA630
6Rated closed loop breaking currentA630
75% rated active load open currentA31.5
8Rated cable charging currentA10
9Rated capacity of open - break no-load transformerkVA1250
10Rated transfer open currentA 1700
11Rated expected short circuit open currentkA 50
12Rated insulation level  
 1min working frequency withstand voltage phase to ground/breakkV42/48
Lightning shock withstand voltage alternate, ground - to - ground/breakkV75/85
13
Mechanical endurance
 5000
14SF6 pressure rating (20 ºC)MPa0.04 ~0.05
15Rated operating voltage of electric mechanismVAC/DC220
16Power frequency withstand voltage of secondary line 1minV2000
17Air leak rate/Year<0.5%

 
Detailed Photos





 
Packaging & Shipping

Company Profile

After Sales Service

 

 

 

 

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$185.00 1 Piece(MOQ)

Gw4- 40.5 Disconnector High Voltage Pantograph Disconnector and Isolator 132kv Surge Arrester/33kv Isolation Switch/Outdoor 33kv 11kv Isolator 630A 1250A

Wenzhou Mingzhe Electric Co., Ltd.
$710.00 1 Piece(MOQ)

Siemens PLC Servo Motor Simatic S7 300 Price Module CPU PLC/ABB Frequecy Converter/ Pneumatic Cylinder/Servo Motor

Wenzhou Mingzhe Electric Co., Ltd.
$9999.00 1 Piece(MOQ)

Injector Bosch Pump Fuel Injection Bosch Pump Nozzle F00bl0j050

Wenzhou Mingzhe Electric Co., Ltd.
$1850.00 1 Piece(MOQ)

Motorola Gp328 Intercom Gp328d+ Explosion-Proof Intercom Xir-P6600I on The Machine Talk Chemical Refueling Siemens CPU Module PLC Control

Wenzhou Mingzhe Electric Co., Ltd.
$186.00 10 pieces(MOQ)

Rh-B-33kv Rated Voltage 33kv Peak Withstand Current 40ka Outdoor High Voltage Isolation Strong Resistance to Dust Disconnector

Yueqing Jasco Electric Co., Ltd.
$34.60 10 Pieces(MOQ)

IP66 Solar DC PV Isolating 32A 20AMP Electrical IP66 Isolator Switch

ZHEJIANG SINGI ELECTRICAL LLC
$6.00 100 Pieces(MOQ)

Bp32 Series 100A - 630A Negative Isolation Switch

Zhejiang Shanmeng Electric Co., Ltd.
$4.00 1000 Pieces(MOQ)

AC400V Fuse Power Switch 160 Emergency Switch Hr17-160 Knife Switch

Zhejiang Shanmeng Electric Co., Ltd.
$15.00 10 Pieces(MOQ)

15kv 630A High Voltage Disconnector Switch

Zhejiang Haivo Electrical Co., Ltd.
$123.00 10 Pieces(MOQ)

Siyan 1600A 3p Disconnector Electric Disconnector DC Generator Transfer Switch

Zhejiang Siyan Electric Technology Co., Ltd