Production Capacity: 80kg/h , 160kg/h.
We are a manufacturer of producing 99.9% N2O gas machine and 99.999% N2O gas euqipment (nitrous oxide) since 2012 year, since that we have also developed and designed of manufacturing N2O gas machines.
The N2O gases are used for production of Integrated circuit device,IC card, LED, LCD,microelectronics and photovoltaic as well as other industries; It mostly used by electronics factory for making screen of mobile or other electronics products.


Ammonium Nitrate is decomposed in the Melters to give a mixture of Nitrous Oxide & super heated steam. At the same time impurities are produced including Ammonium Nitrate fumes, Nitrogen & other oxides of Nitrogen.

Ammonium nitrate (even technical grade) is melted in a melter. The molten ammonium nitrate flows into a combustion pot where ammonium nitrate is decomposed according to the following reaction.
8kg/hour of medical N2O grade and 100kg/hour of electronics grade N2O with Ammonium Nitrate(AN) Feed | ||||
Our N2O machine produce medical grade N2O ≥99.9% | ||||
Specification | Certified concentration | Analytical method | ||
N2O | ≥99.9 | ≥99.9 | % | HG2685-1995 |
CO | ≤10 | ≤10 | ppm | |
CO2 | ≤250 | ≤250 | ppm | |
H2O | ≤100 | ≤100 | ppm | |
NO-NO2 | ≤0.5 | ≤0.5 | ppm | |
N2 | ≤25 | ≤25 | ppm | |
NH3 | ≤5 | ≤5 | ppm | |
Our N2O equipment produce electronics grade N2O ≥99.999% | ||||
Execution standard: | Test results: | |||
Nitrous oxide purity ≥99.9995% | Nitrous oxide purity ≥99.9995% | |||
Oxygen content <0.5 (PPm) | Oxygen content <0.5 (PPm) | |||
Nitrogen content <2 (PPm) | Nitrogen content <2 (PPm) | |||
CO2 content <0.5 (PPm) | CO2 content <0.5 (PPm) | |||
Moisture content <1 (PPm) | Moisture content <1 (PPm) | |||
Impurity content <5 (PPm) | Impurity content <5 (PPm) | |||


The gas containing some nitrogen is then stored in the gas balloon. The gas is compressed with a compressor, dried in a drier and then refrigerate when it becomes liquid. Liquid nitrous oxide is stored in high-pressure storage vessel into cylinders and the gas is filled by weight. In a low pressure plant the gas after refrigeration is stored in a storage tank and from there it is filled in cylinders with a pump. Each batch is analyzed in the laboratory to ensure quality of the product and proper record is maintained.