Medical Ivd Rapid Diagnostic Test Kits Cea Test Strip

Price $0.60 Compare
Min Order 5000 Pieces
Availability In Stock
Shipping From Guangdong, China
Popularity 265 people viewed
Quantity
+-
 

Dewei Medical Equipment Co., Ltd

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
CEA-DW02
IVD Reagent
Whole Blood, Serum, Plasma
10 Minutes
24 Months From The Date of Manufacture
5 Ng/Ml
98.5%
98.6%
Dewei
Cartons
25/40tests/box
Foshan, China
3822190090
Product Description
Product Description

INTENDED USE
The Carcinoembryonic antigen (CEA) Rapid Test (Whole Blood/Serum/Plasma) is a rapid visual immunoassay for the qualitative presumptive detection of human carcinoembryonic antigen (CEA) in human whole blood, serum, or plasma specimens. This kit is intended for use as an aid in the diagnosis of various cancers.

PRINCIPLE
The CEA Rapid Test detects human carcinoembryonic antigen (CEA) through visual interpretation of color development on the internal strip. CEA antibodies are immobilized on the test region of the membrane. During testing, the specimen reacts with CEA antibodies conjugated to colored particles and precoated onto the sample pad of the test. The mixture then migrates through the membrane by capillary action, and interacts with reagents on the membrane. If there are sufficient CEA antigens in the specimen, a colored band will form at the test region of the membrane. The presence of this colored band indicates a positive result, while its absence indicates a negative result. The appearance of a colored band at the control region serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred.

MAIN CONTENTS
• Rapid test cassette with desiccant.
• Buffer
• Pipette
• Package insert

SAMPLE COLLECTION
• The CEA Rapid Test is intended for use with human whole blood, serum, or plasma specimens only.
• Only clear, non-hemolyzed specimens are recommended for use with this test. Serum or plasma should be separated assoon as possible to avoid hemolysis.
• Perform testing immediately after specimen collection. Do not leave specimens at room temperature for prolonged periods. Serum and plasma specimens may be stored at 2-8°C for up to 3 days. For long term storage, specimens should be kept below -20°C. Whole blood collected by venipuncture should be stored at 2-8°C if the test is to be run within 2 days of collection. Do not freeze whole blood specimens. Whole blood collected by fingerstick should be tested immediately.
• Containers containing anticoagulants such as EDTA, citrate, or heparin should be used for whole blood storage.
• Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Avoid repeated freezing and thawing of specimens.
• If specimens are to be shipped, pack them in compliance with all applicable regulations for transportation of etiological agents.
• Icteric, lipemic, hemolysed, heat treated and contaminated specimens may cause erroneous results.

STORAGE AND STABILITY
• Store at 2 ~ 30 º C in the sealed pouch for 24 months.
• Keep away from direct sunlight, moisture and heat.
• DO NOT FREEZE.

DIRECTION OF USE
Bring tests, specimens, buffer and/or controls to room temperature (15- 30°C) before use. 1. Remove the test from its sealed pouch, and place it on a clean, level surface. Label the device with patient or control identification. For best results, the assay should be performed within one hour. Using the provided disposable pipette, transfer 1 drop of whole blood, serum or plasma specimen to the specimen well (S) of the cassette, then add 1 drop of buffer and start the timer. Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result window. As the test begins to work, color will migrate across the membrane. 2. Wait for the colored band(s) to appear. The result should be read within 15 minutes. Do not interpret the result after 20 minutes.

INTERPRETATION OF RESULTS
POSITIVE: The presence of two lines as control line (C) and test line (T) within the result window indicates a positive result.
NEGATIVE: The presence of only control line (C) within the result window indicates a negative result.
INVALID: If the control line (C) is not visible within the result window after performing the test, the result is considered invalid. Some causes of invalid results are because of not following the directions correctly or the test may have deteriorated beyond the expiration date. It is recommended that the specimen be re-tested using a new test.

For further operation or performance details, please refer to final instruction manual.

Detailed Photos

 

Company Profile
Dewei Medical Equipment Co.,Ltd was one of the earliest high-tech biological companies focusing on rapid diagnostics in China. it is a professional manufacture and exporter in the area of medical lines.Factory is located in Foshan city ,Guangdong Province.
Dewei Medical Equipment Co.,Ltd was one of the earliest high-tech biological companies focusing on rapid diagnostics in China. it is a professional manufacture and exporter in the area of medical lines.Factory is located in Foshan city ,Guangdong Province.

 

Certifications

Exhibition


Packaging & Shipping

FAQ

1.Are you a Manufacturer?
Yes,we are manufacturer based in Foshan,China with 100 workers,more than 5000 square meter non-dust workshop,advanced automate machines and professional R&D team ensure the high quality,speedy delivery and large production capacity.

2.Can we put our logo/text om the product or package?
Yes,we can do OEM or even ODM.All of our products can be customized.

3.Can you provide free samples?
Yes, free sample are available.

4.How long is your production time?
Our production time is usually two weeks after receiving the deposit and four weeks for one contaoner order quantity.

5.How to make the payment?
By T/T,L/C,Paypal,Western union and made in China is also acceptable
.

 

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$0.35 5000 Pieces(MOQ)

Methadone Metabolite (EDDP) Drug of Abuse for Urine Sample Rapid Test

Dewei Medical Equipment Co., Ltd
$1.00 5000 Pieces(MOQ)

Malaria PF PV Rapid Test Kit on Antigens of Whole Blood Sample Device

Dewei Medical Equipment Co., Ltd
$0.62 1000 Pieces(MOQ)

CE Prostate Specific Antigen (PSA) Rapid Test Kit Tumor Marker

Dewei Medical Equipment Co., Ltd
$0.15 5000 Pieces(MOQ)

Early Pregnancy 10 25miu/Ml HCG Human Chorionic Gonadotropin Rapid Test

Dewei Medical Equipment Co., Ltd
$0.80 10000 Pieces(MOQ)

Home Use Fobt Fecal Occult Blood Rapid Test

Henan Season Medical Device Co., Ltd.
$0.50 1000 Pieces(MOQ)

Dewei One Step Fecal Occult Blood Fob Detection Kit Stool Test

Dewei Medical Equipment Co., Ltd
$0.27 1000 Pieces(MOQ)

One Step Tumor Maker H. Pylori Antigen Test

Equinox Biotech Co., Ltd.
$2.00 1000 Pieces(MOQ)

Singclean Hot Sale CE Approved Wholesale Rapid Medical Ivd HCG HIV HBV Doa Mau Diagnostic Pregnancy Test Kit for Home

Hangzhou Singclean Medical Products Co., Ltd.
Negotiable 1 Piece(MOQ)

T136H - Tianlong Tuberculous Bacillus DNA Extraction Kit

Xi'an Tianlong Science and Technology Co., Ltd.
$25.00 500 Pieces(MOQ)

Supplier 13c Urea Breath Rapid Test for Children H. Pylori Infection

Beijing Richen-force Science & Technology Co., Ltd.