| MS-15 15W Switching Power Supply | |||
| Project | Technical index | ||
| Output | DC voltage | 12V | 24V |
| Rated current | 1.25A | 0.62A | |
| Rated power | 15.6W | 16.8W | |
| Ripple and noise | <120mV | <150mV | |
| Voltage accuracy | ±1% | ||
| Output voltage regulation range | ±10% | ||
| Load adjustment rate | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | ||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |
| Efficiency (typical) | >82% | >84% | |
| Working current | <0.3A 110VAC <0.15A 220VAC | ||
| Impulse current | 110VAC 18A, 220VAC 36A | ||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |
| Short circuit protection | +VODrop to undervoltage point to close output | ||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |
| Leakage current | Input output 1.5KVACtime <5mA | ||
| Leakage current | Input output 220VACtime <1mA | ||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | ||
| Other | Size | 87*37*60mm (L*W*H) | |
| Net Weight /Gross Weight | 0.15/0.18 KG | ||
| MS-25 25W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 5V | 12V | 24V |
| Rated current | 4A | 2.1A | 1A | |
| Rated power | 20W | 25.2W | 24W | |
| Ripple and noise | <50mV | <120mV | <150mV | |
| Voltage accuracy | ±2% | ±1% | ||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >78% | >82% | >84% | |
| Working current | <0.5A 110VAC <0.25A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVACtime <5mA | |||
| Leakage current | Input output 220VACtime <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 87*37*60mm (L*W*H) | ||
| Net Weight /Gross Weight | 0.15/0.18 KG | |||
| MS-35 35W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 5V | 12V | 24V |
| Rated current | 6A | 2.9A | 1.5A | |
| Rated power | 30W | 34.8W | 36W | |
| Ripple and noise | <50mV | <120mV | <150mV | |
| Voltage accuracy | ±2% | ±1% | ||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >78% | >82% | >84% | |
| Working current | <0.8A 110VAC <0.35A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVACtime <5mA | |||
| Leakage current | Input output 220VACtime <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 87*37*60mm (L*W*H) | ||
| Net Weight /Gross Weight | 0.15/0.18 KG | |||
| MS-50 50W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 5V | 12V | 24V |
| Rated current | 8A | 4.2A | 2.1A | |
| Rated power | 40W | 50.4W | 50.4W | |
| Ripple and noise | <50mV | <120mV | <150mV | |
| Voltage accuracy | ±2% | ±1% | ||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >78% | >82% | >84% | |
| Working current | <0.8A 110VAC <0.35A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 111*36*78mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3/0.35KG | |||
| MS-60 60W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 5A | 2.5A | 1.25A | |
| Rated power | 60W | 60W | 60W | |
| Ripple and noise | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±1% | |||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >82% | >84% | >84% | |
| Working current | <0.8A 110VAC <0.35A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 111*36*78mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3/0.35KG | |||
| MS-75 75W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 6.25A | 3.12A | 1.56A | |
| Rated power | 75W | 75W | 75W | |
| Ripple and noise | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±1% | |||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Incput | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >84% | >84% | >84% | |
| Working current | <1A 110VAC <0.65A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | vInput output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 111*36*78mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3/0.35KG | |||
| MS-100 100W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 8.3A | 4.1A | 2.1A | |
| Rated power | 99.6W | 100.8W | 100.8W | |
| Ripple and noise | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >82% | >84% | >84% | |
| Working current | <1.8A 110VAC <1.1A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 159*38*98mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3KG | |||
| MS-120 120W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 10A | 5A | 2.5A | |
| Rated power | 120W | 120W | 120W | |
| Ripple and noise | <120mV | <150mV | <150mV | |
| Voltage accuracy | ±1% | |||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >82% | >84% | >84% | |
| Working current | <2A 110VAC <1.3A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 159*38*98mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3KG | |||
| MS-250 250W Switching Power Supply | |||||
| Project | Technical index | ||||
| Output | DC voltage | 5V | 12V | 24V | 48V |
| Rated current | 40A | 20.8A | 10.4A | 5.2A | |
| Rated power | 200W | 249.6W | 249.6W | 249.6W | |
| Ripple and noise | <50mV | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±2% | ±1% | |||
| Output voltage regulation range | ±10% | ||||
| Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | ||
| Linear adjustment rate | <±0.5% | ||||
| Input | Voltage range | 185-264VAC 47Hz~63Hz (254VDC~370VDC) | |||
| Efficiency (typical) | >82% | >84% | >84% | ||
| Working current | <2.5A 220VAC | ||||
| Impulse current | 220VAC 36A | ||||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||||
| Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
| Short circuit protection | +VODrop to undervoltage point to close output | ||||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
| Leakage current | Input output 1.5KVAC <5mA | ||||
| Leakage current | Input output 220VAC <1mA | ||||
| Isolation resistance | Input output,Input - Housing, Output - Housing:500VDC/100MΩ | ||||
| Other | Size | 199*50*110mm(L*W*H) | |||
| Net Weight /Gross Weight | 0.72/0.78KG | ||||
| MS-350 350W Switching Power Supply | |||||
| Project | Technical index | ||||
| Output | DC voltage | 12V | 24V | 36V | 48V |
| Rated current | 29A | 14.5A | 9.7A | 7.3A | |
| Rated power | 350W | 350W | 350W | 350W | |
| Ripple and noise | <120mV | <240mV | <240mV | <240mV | |
| Voltage accuracy | ±1.0% | ||||
| Output voltage regulation range | ±10% | ||||
| Load adjustment rate | ±0.5% | ||||
| Linear adjustment rate | ±0.5% | ||||
| Input | Voltage range | 90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC | |||
| Efficiency (typical) | >83% | >85% | >86% | >86% | |
| Working current | 110VAC 25A, 220VAC: 50A | ||||
| Impulse current | <5.5 A 115VAC <2.9A 230VAC | ||||
| Start, rise, hold time | 200ms,50ms,20ms :230VAC | ||||
| Protect | overload protection | 105% - 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
| Short circuit protection | 115%-145% | ||||
| Undervoltage protection | 10%-45%VOUT | ||||
| Temperature protection | Rth3: ≥ 55 ºC fan start, ≥ 50 ºC fan close, ≥ 85 ºC close output (5v-15v) | ||||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 2.5kvac output shell: 0.5kvac for 1 minute | |||
| Leakage current | Input output 1.5KVAC <6mA | ||||
| Leakage current | Input output 220VAC <1.5mA | ||||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | ||||
| Other | Size | 199*38*98mm(L*W*H) | |||
| Net Weight /Gross Weight | 0.62/0.65 KG | ||||