| tracer gas: | Carbon dioxide (CO2); ethanol (C2H6O); acetone (C3H6O); nitrous oxide (N2O) | ||
| measuring range: | CO2:0-5000PPM;C2H6O:0-100%LEL;C3H6O:0-100PPM;N2O:0-10000PPM | ||
| resolution ratio: | CO2:1PPM;C2H6O:0.1%LEL;C3H6O:0.01PPM;N2O:1PPM | ||
| Extended gas: | Support for 1-5 sensors, any combination of various types of gas sensors, please refer to the relevant sensor parameters | ||
| Dust particles: | Optional PM2.5 laser dust particle sensor (0.3um, 2.5um, 10um) | ||
| humiture: | Temperature detection range: -40 ~ 120ºC, and humidity detection range: 0-100% RH | ||
| detection mode: | Pump suction type, built-in strong suction pump, flow rate: 500 mL/min adjustable, can work in the micro-negative pressure environment | ||
| Detection accuracy: | ≤±3% | linear error: | ≤±2% |
| response time: | 30 seconds (T90) | zero drift: | ≤±2%( F.S) |
| recovery time: | Admito 20 seconds | repetitivenes s: | ≤±2% |
| Detection mode: | Real-time detection and timing detection can be set | ||
| memory module: | Real-time storage and timing storage can be set; a single channel can store 30800 data groups to view historical data on the screen | ||
| Print mode: | Optional micro printer to print data, can be set: printing cycle, automatic printing, manual printing | ||
| explosion- proof sign: | Ex iaIIC T4 Ga | Shell material: | ABS+PC |
| levels of protection: | IP66 | working temperature: | -20~ 50ºC |
| working power supply: | 4000mA rechargeable polymer battery | Working humidity: | 95% RH, and no condensation |
Size weight: | 220*85*55 mm(L×W×H) 0.5 Kg (instrument net weight) | working pressure: | -30Kpa ~ 100Kpa |
| standard fitting: | One instrument box, instruction manual, qualification certificate, USB charger, data cable, calibration cover | ||
Optional accessories: | microwriter PM2.5 laser dust particle sensor Other various types of sensors, can be customized Water Gas Filter | ||
operative norm: | GB3836.1-2010 The Explosive Environment- -Part 1: General Requirements for Equipment GB3836.4-2010 Explosive Environment-Part 4: Equipment protected by an intrinsically safe "i" | ||










Audited Supplier