YZ-EM5P Portable UV Flue Gas Analyzer is mainly composed by monitoring unit of gaseous pollutants (SO2, NOX, CO, CO2), monitoring unit of flue gas parameters (e.g. oxygen content), data collection & processing unit.
The structure consists of flue gas sampler, transmission pipeline, flue gas pre-processor and analyzer.
EM-5P is equipped with easy to use touch screen, large storage capacity, multi-port output and printer for real-time monitoring data.
Feature
- Adopt Stoichiometric Algorithm, low detection limit and small temperature drift
- NOX content can be directly obtained by measuring NO and NO2 without NO2→NO converter
- Full UV spectrum measurement, without cross interference
- Electronic scanning of full spectrum, no optical moving parts
- Low requirements for measured gas, able to applied in dust and high humidity working condition
Applied in exhaust emission monitoring and process control in coal-fired power plant, garbage power plant, cement plant, glass plant, lime factory, ceramics factory, sintering process, coke oven, desulfurization technology, denitration technology, etc.
Specification
Analyzer model: | normal temp type: condensation & water removal high temp type: full-course high temperature |
Measurement technology: | UV-DOAS (SO2, NO, NO2), electrochemistry (O2), nfrared/laser (CO), infrared/laser TDLAS (CO2) |
Range: | 0~50~1500mg/m3 (SO2, NO, NO2), 0~25% (O2), 0~500~10000ppm (CO), 0~65% (CO2) |
Indication error: | ≤2%F.S. |
Zero drift: | ≤±2%F.S./24h |
Span drift: | ≤±2%F.S./24h |
Response time: | ≤90s (T90) |
Preheating time: | ≤90s (T90) |
Power: | 220VAC±22V, normal temp type: 50W/high temp type: 350W |
Working temperature: | 5ºC~45ºC |
Working humidity: | 0~85%RH |
Dimension: | 498mm×182mm×236mm |
Weight: | 12kg |