Material: closed-cell PU elastomer (Polyurethane)
Color: dark green
Dimensions can be customized,Other dimensions, punched and moulded parts on request.
Thermotest is using "Sylodyn," a polyurethane dampening material developed by Getzner, a company with worldwide success in railroad and construction, in subway, railway, and highway soundproofing and dampening. Compared to existing dampening rubber, Sylodyn is more durable, more stable and is able to be made thinner in order to fit into small spaces, making installation quick and easy.



Range of use | Compressive | Deformation |
Shape factor-dependent, the specified values apply to shape factor of q=3 | ||
Static range of use (static loads) | up to 3.0N/mm2 | approx. 12% |
Dynamic range of use (dynamic loads) | up to 4.5N/mm2 | up to 16% |
Load peaks (occasional, brief loads) | up to 12.0 N/MM2 | approx. 30% |
Technical Data
Material Properties | Test Methods | Comment | |
Mechanical loss factor | 0.06 | DIN 53513 1 | temperature-, frequency-, specific load- and amplitude-dependent |
Compression set 2 | < 5 % | EN ISO 1856 | 25 % deformation, 23 °C, 72 h, 30 min after removal of load |
Static shear modulus3 | 2.4N/mm2 | DIN ISO 1827 1 | at a pretension of 3.0 N/mm2 |
Dynamic shear modulus3 | 2.8N/mm2 | DIN ISO 1827 1 | at a pretension of 3.0 N/mm2, 10 Hz |
Coefficient of friction (steel) | ≥ 0.6 | Getzner Werkstoffe | dry, static friction |
Coefficient of friction (concrete) | ≥ 0.7 | Getzner Werkstoffe | dry, static friction |
Thermal conductivity | 0.16 W/mK | DIN EN 12664 | |
Temperature range | -30 °C to 70 °C | short term higher temperatures possible | |
Flammability | class E | EN ISO 11925-2 | normal combustible, EN 13501-1 |
1Measurement/evaluation in accordance with the relevant standard
2 The measurement is performed on a densitydependent basis with differing test parameters
3 Values apply to shape factor q = 3

0.3 N/mm2/s.
· Testing be tween s andblasted, flat steel-plates; recording of the 1st load, with filtered starting range in accordance with ISO 844, testing at room temperature.
· Shape factor q = 3

· Measurement in accordance with DIN 53513
· Shape factor q = 3

free dome, consisting of a mass and an elastic bearing made of
Sylodyn® HRB HS 3000 on a rigid surface.
· Parameter: thickness of the Sylodyn® bearing
· Shape factor q = 3

· Parameter: permanent static load
· Shape factor: q = 3

amplitude of vibration.
· Sylodyn® HRB HS 3000 materials exhibit a negligible dependency of
amplitude.