Professional Manufacturer Low Voltage Twisted Aerial Concentric ABC Cable

Price $100.00 Compare
Min Order 300 Meters
Availability In Stock
Shipping From Jiangsu, China
Popularity 324 people viewed
Quantity
+-
 

Jiangsu Dongfeng Cable Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
ABC
Construction, Overhead, Underground, Industrial, Power Station, Telecommunication
Low and Medium Voltage Cable
DC & AC
Bare
PVC
Round Wire
Aluminum
ISO, CCC
ABC
Yunfeng
YUNFENG
Drum
3x120
China
7614900000
Product Description

 


Self-supporting LV-ABC Lines
Code: ABC 0.6/1kV, NFA2X, AsXS (n), 1-AES
Standards: HD 626 S1: 1996 Part 4-Section F,
PL WT92/K396, CSN 34761-4F
Construction: Phase Conductors: Aluminum conductors with XLPE insulation. 
Neutral Messenger: Aluminum conductors with XLPE insulation.
Application: Aerial Bundled Conductors are used
for tributary networks of power buildings
and their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.

Dimensions of phase conductors

Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.(A*)(kN)
(mm)(mm)(mm)(mm)(mm)
164,65,11,21,007,8-2,60
255,66,51,31,0710,11074,17
356,67,51,31,0711,01325,78
507,78,61,51,2512,51658,45
709,310,21,51,2514,020511,32
9511,012,01,71,5016,1-15,30
12012,513,51,81,6017,6-20,00
15013,915,01,81,6018,8-25,00
* defined for ambient temperature of 35°C and max. conductor temperature of 80°C

Dimensions of neutral messenger conductors
Number of phase cores x cross sectionBundle diameter
+ public lighting conductorsapprox.
+ neutral cross section 
(mm²)(mm)
2 x 1615
2 x 2518
2 x 3520
4 x 1618
4 x 25 22
4 x 3525
4 x 5028
4 x 7032
4 x 70 + 1 x 3536
4 x 70 + 2 x 3540
4 x 9537
4 x 12040
4 x 120 + 2 x 3543
4 x 15044


LV-ABC Lines with Bare Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 5-Section D,
 AMKA (SFS 2200)
Construction: Phase Conductors: Aluminum conductors with XLPE insulation. 
Neutral Messenger: Aluminum conductors 
Application: Aerial Bundled Conductors are used for
         tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.

Dimensions of phase conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.tolerancenom.min.min.max.(A*)(kN)
(mm)(mm)(mm)(mm)(mm) 
164,4±0,051,4-7,17,370-
255,9±0,021,4-8,39,195-
356,9±0,021,6-9,710,5115-
508,1±0,251,6-10,811,8140-
709,7±0,251,8-12,813,8180-
12012,8±0,302,0-16,217,4250-
* defined for ambient temperature of 25°C and max. conductor temperature of 70°C

Dimensions of neutral messenger conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.max.(A*)(kN)
(mm)(mm)(mm)(mm)(mm)(mm)
255,9±0,02--5,56,3-7,4
356,9±0,02--6,57,3-10,3
508,1±0,25--7,68,6-14,2
709,7±0,25--9,210,2-20,6
9511,4±0,30--10,812,0-27,9

Dimensions of Cable Bundle
Number of phase cores x cross sectionBundle diameter
+ neutral cross sectionapprox.
(mm²)(mm)
1 x 16 + 2515
3 x 16 + 2522
4 x 16 + 2522
3 x 25 + 3526
4 x 25 + 3526
3 x 35 + 5030
3 x 50 + 7035
3 x 70 + 9541
3 x 120 + 9547



LV-ABC Lines with Insulated Neutral Messenger
Code: ABC 0.6/1kV,
Standards: HD 626 S1: 1996 Part 6-Section E,
 AMKA (SFS 2200)
Construction: Aluminum conductors with XLPE insulation. 
Application: Aerial Bundled Conductors are used for
         tributary networks of power buildings and
their internal networks.
Installation: These cables are not allowed to
be buried, even in conduits.
Dimensions of phase conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.max(A*)(kN)
(mm)(mm)(mm)(mm)(mm) 
164,65,11,2-7,07,8--
255,86,31,4-8,69,4112-
356,87,31,6-10,010,9138-
507,98,41,6-11,112,0168-
709,710,21,8-13,314,2213-
9511,012,01,8-14,615,7258-
12012,013,11,8-15,616,7306-
15013,915,01,7-17,318,6344-
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of neutral messenger conductors
Cross sectionConductor diameterThickness of insulationCore diameterCurrent carrying capacityBreaking load
(mm²)min.max.nom.min.min.max(A*)(kN)
(mm)(mm)(mm)(mm)(mm) 
54,69,29,61,6-12,313,0-16,6
7010,010,21,5-12,913,6-20,5
9512,212,91,6-15,316,3-27,5
* defined for ambient temperature of 30°C and max. conductor temperature of 90°C
Dimensions of Cable Bundle
Number of phase cores x cross sectionBundle diameter
+ public lighting conductorsapprox.
+ neutral cross section 
(mm²)(mm)
3 x 25 + 54,630,0
3 x 35 + K x 16 + 54,633,0
3 x 50 + K x 16 + 54,636,0
3 x 70 + K x 16 + 54,637,5
3 x 70 + K x 25 + 54,6 40,0
3 x 70 + K x 16 + 7041,0
3 x 95 + K x 16 + 7044,0
3 x 120 + K x 16 + 7046,0
3 x 120 + K x 16 + 9547,0
3 x 150 + K x 16 + 7048,0
3 x 150 + K x 16 + 9549,0

Note: K number of public lighting conductors (K can be equal to 0, 1, 2, or 3)



Packing
Our wokshop

Range of Business: 

Cables
Low Voltage Power Cable: 0.6/1kV and Below PVC or XLPE Insulated Power Cable
Medium Voltage Power Cable: 6-35kV XLPE Insulated Power Cable
High Voltage (Extra-high Voltage) Power Cable: 66-500kV XLPE Insulated Power Cable
Bare Conductor and Electrical Wires

Cable Accessories
1~35kv cold shrinkable products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
1~35kv heat shrinkable Products
a. Indoor termination
b. Outdoor termination
c. Straight Through Joint
66kv ~500kv Products
a. Porcelain Outdoor termination
b. Compound Sleeve Termination
c. GIS termination ( Assembly, plug-in Type )
d. Premould termination
e. Straight Joint/ Insulation Joint
f.   Branch Joint
g. Dry and Y shape Branch Joint


Why choose us? 
1. Export to many countries including Iraq, Tanzania and Australia and USA.
2. Best manufacturing and testing equipments imported from Germany, USA and Japan guarantee the best quality with competitive prices. 
3. Professional overseas team guarantees you best pre-and-after sale services.
4. Experienced engineers and workers for more than 20 years ensure the quality and customized products.
5. 5S Management to enhance the qualifications of staff and make better service for customers. 
6. Near Shanghai and Ningbo Port workshop makes it convenient to delivery on time.  
  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$100.00 300 Meters(MOQ)

0.6/1kv XLPE Insulation Low Voltage Copper Conductor PVC Sheath Jacket Steel Armoured/Armored Power Cable

Jiangsu Dongfeng Cable Co., Ltd.
Negotiable 100 Meters(MOQ)

64/110 Kv Underground Cable High Tension Single Core Copper/Aluminum Conductor XLPE Insulated Steel Wire Armoured Electrical Transmission Wire

Jiangsu Dongfeng Cable Co., Ltd.
$2113.00 3 Sets(MOQ)

High Quality Cable Accessory 66kv Fully Prefabricated Type Insulating Joint

Jiangsu Dongfeng Cable Co., Ltd.
$100.00 300 Meters(MOQ)

Aluminum Conductor Steel Reinforced Aluminum Bare ACSR AAC AAAC Power Transmission Line

Jiangsu Dongfeng Cable Co., Ltd.
$15.90 500 Meters(MOQ)

4 Core 16mm 25mm 35mm 50mm 70mm 95mm 120mm 150mm 185mm 240mm Copper Aluminum Armoured Power Cable Price

Henan Hongda Cable Co., Ltd.
$0.95 1 Piece(MOQ)

Shenguan Wholesale Us Plug AC Computer Power Cable C13 Copper Cord for Electric Power Supply Cord Ht Cable

Shenyang Power Cable Factory
$30.00 10000 Feet(MOQ)

UL Standard Medium Voltage Industrial XLPE Epr Urd Mv Mv-90 Mv-105 Power Cable Aluminum Copper Conductor Underground Electric Electrical Wire Construction

Hebei Huatong Wires & Cables Group Co., Ltd.
Negotiable 100 Meters(MOQ)

Aluminum Alloy Almelec Cable 1120 AAC AAAC ACSR Acar Accc All Aluminium Conductor Alloy Overhead Bare Conductor (Chlorine 7/2.50mm, Neon 19/3.75mm)

Shanghai Shenghua Cable Co., Ltd.
$32.90 500 Meters(MOQ)

Copper Aluminum XLPE PVC 185mm 4 Core Steel Wire Armoured Swa Electrical Cable

Henan Hongda Cable Co., Ltd.
$29.00 10000 Meters(MOQ)

XLPE Epr Urd Mv-90 Mv-105 Power Cable Aluminum Copper Conductor

Guangzhouzhujiang Cable Co., Ltd.