Refrigerator Compressor R134A/1234yf DC Compressor Reciprocating Compressor Qdzh70W Cooling Capacity 70W

Price $5.00 Compare
Min Order 1 Piece
Availability In Stock
Shipping From Shanghai, China
Popularity 232 people viewed
Quantity
+-
 

Shanghai Jingyi New Material Technology Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
QDZH70W
Lubricated
Air Cooling
Parallel Arrangement
Horizontal
Closed Type
Single-Stage
Freon
70W
1.15
3500
Tray
70W
8414301100
Product Description


GENERAL REQUIREMENTS FOR PRODUCTS

1.The compressorshouldbe stored indryand ventilated places.
2.The installationrequirements of compressor:the compressor must bemounted horizontally without tiltingan angle more than 5°
3.In order to avoid the entering of debris and moisture,pleasedo not
pull off rubber plugs from the compressor tube.
4.The earth connection should be fixed fimly to the refrigerator'sgroundingdevice.
5.In order to balance the system pressure,compressorrun time intervalshould be no less than 5 minutes.
6.As the compressor is injectedwiththe best quantityof professionalrefrigeration oil which is recognized by company,please do not pourout oraddoil randomly.
7.Insteadof beinginstalledat compressor,the compressoraccessories(such as starter,protector,capacitor,etc.)are in the accessory box.
8.Correctly match the compressor's evaporation temperatureaccording to low,middle and high back pressure and pay attentionto the range ofvoltage and frequency.
9.During transport,the limit height is one layer.Please keep thecompressor always vertically and never upset it while avoiding anyvibration and shock.
10.The compressor can not withstand high voltage(ourcompany hasfinished the test of 1800V,1S)or start and operate under vacuumconditions.
11.Please avoid welding powder and dust entering the surface ofwiring terminal during the welding of connection tubes,or that wouldlead to theunqualified insulating.
12.The system vacuum degree≤0.6665mbar.Please reconfirm theRefrigerant Volume while match the new compressor.Adjust thesystem if necessary.
13.Please inform the comp factory when the same model comp clientautonomouslymatchother refrigeration system models.
14.When design the refrigeration system please take oil return abilityinto full consideration.Otherwise,it would cause the compressorfailure.
15.Be sure to separate vacuum from refrigeration systemwhile not usethevacuum pump.Otherwise,it would cause back ventof oil negativepressure then lead to refrigeration failure.
16.Please keep the storage expirywithln 6 months.If it expired,pleasecheck the sufficiency of gas inside compressor and recharge it whennecessary.
17.Starting and running voltage:according to different workingcondition,compressor canstart under the balance pressure of 0.2MPa(R600a)and 0.5MPa(R134a)and under-15%,+10%rated voltage.
18.The compressor operating ambient temperature should be nohigher than 43ºC.While operating at the highest ambienttemperaturefor a long time,make sure the voltage andpower are within the limitvalue and thecompressor winding temperature not exceed 120ºC(R600a),130ºC(R134a).Otherwise,it would cause thermal protection evencompressor failure.


R134a,R290 special requirement:
1.Vacuum pump and filling equipment must be exclusively used inR134a,R290.
2.Organics that couldn't mix with R134a,R290.must not be used inthe refrigeration system.
3.Device fordrying and filtering mustapply to R134a,R290.
4.R134a,R290 compressor's exposure time should be as short as possible,and itcouldn't over 10min.
5.R134a,R290 refrigeration system should control the content of water,impurity,ceresin wax,silicone oil and chloridion strictly.
6.There is specified oil in R134a,R290compressor,please don'tpour out oradd optionally.


R600a special requirement:
1.R600a compressor must use PTC starter.
2.For safety,charge volum of working medium should not be over150g in R600a.
3.R600a's kindling material will be ignited when the temperature isover 460C°or the air concentration is 1.98%-8.5%byvolume.


Environment protection:
1.During the whole production process of compressor,refrigerant oilshould not be poured put optionally,carton,wooden support andnylon paper should be retrieved in order to avoid the environmentalpollution.
2.Baixue compressor and accessory which meet RoHS requirementshould be all marked.Compressor's data plate,packing and accessorybox all have RoHS mark,please pay attention to not be mixed in the
use.


Standard:
1.GB/T5773-2004
2.GB/T9098-2008
3.GB4706.17-2010


  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$5.00 1 Piece(MOQ)

Refrigerator Compressor R600A DC Compressor Reciprocating Compressor Qdzy60d Cooling Capacity 105W

Shanghai Jingyi New Material Technology Co., Ltd.
$5.00 1 Piece(MOQ)

Refrigerator Compressor R600A Lbp Compressor Reciprocating Compressor Vy33r45A Cooling Capacity 50W

Shanghai Jingyi New Material Technology Co., Ltd.
$2.45 200 kg(MOQ)

vacuum Pump Lubricant

Shanghai Jingyi New Material Technology Co., Ltd.
$2.45 200 kg(MOQ)

Special High Adhesion Running-in Lubricant

Shanghai Jingyi New Material Technology Co., Ltd.
$1000.00 1 Piece(MOQ)

2HP Tecumseh Compressor R22 Caj9513t Tecumseh Chiller Compressor Price

TAYLOR HOLDINGS LIMITED
$558.00 1 pieces(MOQ)

Refrigeration Compressor Mt125hu4dve Mt125hm4cve Mtz125hu4ve Mt125hv4dve 10HP Maneurop Reciprocating Compressor for Cold

Foshan Bingke Technology Co., Ltd.
$800.00 1 pieces(MOQ)

6.5HP 70L Honda Gasoline Engine Industrial Petrol Air Compressor

Yancheng Goodlark International Trade Corp., Ltd
Negotiable 10 Sets(MOQ)

CE SGS 70L 850wx2 Oil Free Air Compressor (GDG70)

Taizhou City Ouye Electromechanical Co., Ltd.
$110000.00 1 Set(MOQ)

Oil Free Reciprocating Natural Gas Compressor for CNG Refueling Station

Wuhan Qidakon Energy Equipment Co. Ltd.
$58500.00 1 Set(MOQ)

Manufacturer Direct Selled High Pressure Nitrogen Generator Oil Gas Booster Compressor with High Temperature Resistance Design for Middle East

JIANGXI BOBAI ENERGY EQUIPMENT CO., LTD.