Solis Three Phase Inverters
Solis-GC(100-125)K
S5-GC(100-125)K three-phase series string inverter adopt 10 MPPT design to provide a more flexible configuration scheme with a smaller environmental impact rate and higher generation efficiency. Anti-resonance, supporting over 6MW paralleled in one transformer, Strings intelligent monitoring, Smart I-V Curve Diagnosis supported
100-125kW Three Phase Inverter Leading Features:


Applications:
Villa, Hotel, Residential electricity, Hospital, Museum, Church, Farm
| DATASHEET | Solis-(215-255)K-EHV-5G | |||||||||
| Models | 215K-PLUS | 250K | 250K-PLUS | 255K | 255K-PLUS | |||||
| Input DC | ||||||||||
| Max. input voltage | 1500 V | |||||||||
| Rated voltage | 1080 V | |||||||||
| Start-up voltage | 500 V | |||||||||
| MPPT voltage range | 480-1500 V | |||||||||
| Max. input current | 9*30 A | 14*26 A | 12*30 A | 14*26 A | 12*30 A | |||||
| Max. short circuit current | 9*50 A | 14*40 A | 12*50 A | 14*40 A | 12*50 A | |||||
| MPPT number/Max. input strings number | 9/18 | 14/28 | 12/24 | 14/28 | 12/24 | |||||
| Output AC | ||||||||||
| Output power | 215 kVA@30°C / 205 kVA@ 40°C / 195 kVA@50°C | 250 kVA@30°C / 235 kVA@40°C / 220 kVA@50°C | 255 kVA@30°C / 235 kVA@40°C / 220 kVA@50°C | |||||||
| Rated grid voltage | 3/PE, 800 V | |||||||||
| Grid voltage range | 640-920 V | |||||||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||||||
| Max. output current | 155.2 A | 180.4 A | 184.0 A | |||||||
| Power factor | >0.99 (0.8 leading - 0.8 lagging) | |||||||||
| THDi | <3% | |||||||||
| Efficiency | ||||||||||
| Max. efficiency | 99.0% | |||||||||
| EU efficiency | 98.8% | 98.7% | 98.8% | 98.7% | 98.8% | |||||
| Protection | ||||||||||
| DC reverse-polarity protection | Yes | |||||||||
| Short circuit protection | Yes | |||||||||
| Output over current protection | Yes | |||||||||
| Surge protection | DC Type II / AC Type II | |||||||||
| Grid monitoring | Yes | |||||||||
| Anti-islanding protection | Yes | |||||||||
| Temperature protection | Yes | |||||||||
| Strings monitoring | Yes | |||||||||
| I/V Curve scanning | Yes | |||||||||
| Night time SVG function | Yes | |||||||||
| Integrated PID recovery | Yes | |||||||||
| Integrated DC switch | Yes | |||||||||
| General Data | ||||||||||
| Dimensions (W*H*D) | 1125*770*384 mm | |||||||||
| Weight | 109 kg | 113 kg | ||||||||
| Topology | Transformerless | |||||||||
| Self-consumption (night) | <2 W | |||||||||
| Operating ambient temperature range | -30 ~ +60°C | |||||||||
| Relative humidity | 0-100% | |||||||||
| Ingress protection | IP66 | |||||||||
| Cooling concept | Intelligent redundant fan-cooling | |||||||||
| Max. operation altitude | 4000 m | |||||||||
| Grid connection standard | EN50549, G99, AS4777.2, VDE0126, IEC61727, VDE4110, CEA 2019 | |||||||||
| Safety/EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 | |||||||||
| Features | ||||||||||
| DC connection | MC4 connector | |||||||||
| AC connection | OT terminal (max. 300 mm²) | |||||||||
| Display | LCD | |||||||||
| Communication | RS485, Optional: PLC | |||||||||

Single Phase 220-240V 50/6Hz
Three Phase 380-415V 50/6Hz


Three Phase 380-415V 50/6Hz
Three Phase 380-415V 50/6Hz


Three Phase 800V 50/6Hz














Audited Supplier