Main application areas
1. EOR (chemical flooding oil) indoor and field monitoring study
2. surfactants, detergents, emulsions and foams study
3. Study of fuel oil, lubricants, paints, inks and coatings
4. Research paper products, photographic materials, pesticides etc
Feature
1. The whole process is controlled by PC computer and a pre-SBC, the use of computer multimedia video technology to collect spinning drop of image analysis,
2. The master program is a Windows interface, easy operation, the image as a standard BMP file that can be stored in print.
3. The tension measurement wide range, from 10-5mN / m to 100mN / m, across seven orders of magnitude, the meter full scale tension.
4. The high accuracy, providing the number of stalls magnification, hair width can be enlarged to over one hundred pixels, greatly improve the measurement accuracy of ultra-low interfacial tension.
5. One machine can measure the interfacial tension and contact angle, thereby performing wet ability studies. For contact measurement under normal circumstances, the instrument can make liquid droplets in a regular rotation of the body, thus ensuring measurement precision and accuracy. In addition, it can also be measured when the contact angle of the liquid / liquid interfacial tension of ultra-low value, and very convenient, this is the other contact angle measuring instrument difficult to do.
6. With electric heating temperature control system, capable of constant temperature experiments.
Technical Specifications and Features
1. Tension measuring range: surface and interfacial tension 1x10-5 -100mN / m
2. The reading range: 0-4mm (2mm and 4mm provides high-purity quartz sample tube)
3. Reading Accuracy 0.001mm
4. Speed control range 1000-10000r / min Accuracy: 0.1%
5. Temperature display range: 0-100 ºC (built-in heating RT + 5 ºC to 80 ºC or external bath temperature)
6. Temperature display accuracy: ± 0.1 ºC
7. Computer and stand-alone real-time set temperature and speed
8. The video detection system Resolution: 768x576
9. The video capture rate: 25 frames / sec.
10.RS-232 serial port (test data); VIDEO RCA Interface (video capture)
11.220V / 50 Hz or 110V / 60Hz
SIT2000B2 spinning drop interfacial tension / Intravenous contact angle measuring instrument (dual-use) can be used to measure the contact angle of a liquid on a solid, that is a liquid wet ability on solid, can also use the spinning drop method to measure the surface tension of the liquid, liquid / liquid interfacial tension. The instrument consists of two separate parts, a common optical video system.




