| Large LCD display, with backlight, suitable for working in various ambient light conditions. |
| Disposable IV set of any brand is suitable for this pump |
| Three working modes: Rate/Volume/Time mode |
| Purge, KVO function |
| Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature. |
| Remote Controller makes operating more convenient. |
| Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission. |
| Simple and convenient in operating, intuitive presence of working status. |
| Audible and Visible alarms |
| Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
| Size: 188 mm(L)*198 mm(W)*228 mm(H) |
| Net Weight: 2.2kg |
Technical Specifications
| Pump Type | Drip type infusion pump |
| Pumping Way | Peristalic fingers |
| Adjustable Drop Rate Range | 1~400 drops/min (step: 1 drop/min) |
| Adjustable Volume Rate Range | 1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h) |
| Flow Precision | Within 3% more or less(using the IV set appointed by the manufacturer or calibrated high quality IV set) |
| Mechanical precision | within 2% more or less |
| Purge Rate | 800 ml/h |
| KVO Rate | 1 ml/h (1~300 ml/h) 3 ml/h (greater than 300 ml/h) |
| Infusion Volume Range | 1 ml~9999.9 ml (step: 0.1 ml) |
| Maximum Accumulated Volume | 9999.9 ml (step: 0.1 ml) |
| Time Range | 1 min~9999 min (step: 1 min) |
| Occlusion Alarm Threshold | High: 800 mmHg+-200 mmHg (106.7kPa+-26.7kPa) Medium: 500 mmHg+-100 mmHg (66.7kPa+-13.3kPa) Low: 300 mmHg+-100 mmHg (40.7kPa+-13.3kPa) |
| Alarm | Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
| Air Bubble Detector Method | ultrasonic wave, sensitivity: more than or equal 25 μL |
| Fuse | F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity), 2 pcs (installed inside pump). |
| Power Supply | AC 85~265V, 50/60Hz; |
| Internal Battery | 11.1V rechargeable li-ion battery. Capacity:more than or equal 2000mAh; the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for 8 hours (Medium rate specified by GB 9706.27-2005). |
| Power | less than or equal 40VA |
| Size | 188 mm(L)*198 mm(W)*228 mm(H) |
| Weight | 2.2KG |
| Environment Requirements | Transport Ambient Temperature: -30°C~+55°C Relative Humidity: 20%~95% (non-condensing) Atmosphere Pressure: 70kPa~106kPa Storage Ambient Temperature: -30°C~+55°C Relative Humidity: 20%~95% Atmosphere Pressure: 70kPa~106kPa Operation Ambient Temperature: +5~+40°C Relative Humidity: 20%~90% Atmosphere Pressure: 86kPa~106kPas |
| Calibration function | disposable IV set of any brand is suitable for this pump |
| Three working modes | Rate/Volume/Time mode |
| Alarm | Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
| infusion monitoring system (Optional), the status of each pump is displayed in real time at the central station through wireless transmission. | |
| 4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions. | |
| Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication | |




Packing and shipping
1. Package: double carton boxes
2. Port: Shenzhen China, Shanghai China
3. Delivery time: 3-5 working days after receipt of payment
Our Advantages:
Certificates: 
Payment terms
T/T in advance, MoneyGram, Trade Assurance, Western Union, Escrow, Paypal, Credit Card!
Company information:
Exhibitions

Welcome to contact us!








Audited Supplier