Timelec DC 2p 250V T1+T2 Industrial Protector Surge Arrester for Home

Price $9.00 Compare
Min Order 60 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 382 people viewed
Quantity
+-
 

Taimu Electrical (Hangzhou)Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
TMSPD7
Power Source Arrester
Zinc Oxide Arrester
Tandem Arrester
AC/DC System
Small
Low Voltage
Cuboid
PBT Fireproof
ROHS, ISO9001, CE
Timelec
275V / 255V
20kA
40kA
1.5kV
IEC61643-11
IP20
Class II, T2
Timelec, OEM / Private Label brands
Carton Box
18mm
China
853620
Product Description
Product Description

SPD Surge Protective Devices are designed to protect against transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousands of volts and can cause immediate or intermittent equipment failure. However, lightning and utility power anomalies only account for 20% of transient surges. The remaining 80% of surge activity is produced internally. Although these surges may be smaller in magnitude, they occur more frequently and with continuous exposure can degrade sensitive electronic equipment within the facility.


A power surge is a brief overvoltage event that can damage electrical devices and is a common cause for the failure of electrical equipment. Surges can damage and reduce the lifespan of:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

NEW 2020 National Electrical Code Requirements
All new and renovated homes are required to be protected by Listed and Approved Type 1 or Type 2 Surge Protective Devices.

Type 1:
Permanently connected Surge Protective Device.  Protects against external and internal surges. May be installed inside or outside the home.

Type 2:
Permanently connected Surge Protective Device installed in, or next to, breaker box. Protects again internal or external surges.

Type 3:
Extra protection. Point-of-use Surge Protective Device. Must be used in conjunction with Type 1 or Type 2 SPD to meet 2020 code requirements.

Use Type 1, 2, and 3 SPDs for the best level of protection.  
 

Product Parameters
SPD according to EN 61643-11/IEC61643-11Type 2/Class II
Energy coordination with terminal equipment (10m)Type 2+ Type 3
Nominal voltage (AC) (Un)230V (50/60Hz)
 MOV (Varistors)GDT (Spark gap)
Max. continuous operating voltage (AC) (Uc)275V (50/60Hz)255V (50/60Hz)
Nominal discharge current (8/20s) (In)20KA20KA
Max. discharge current (8/20s) (Imax)40KA40KA
Voltage protection level (L-PE)/(N-PE) (Up)1.5KV1.3KV
Response time (tA)25nS
Max. mains-side overcurrent protection125AgG
Short-circuit withstand capability for max. mains-side50KA
Overcurrent protection (ISccR)
Temporary overvoltage (TOV)(UT)-- Characteristic335V/5 Sec-- withstand
Temporary overvoltage (TOV)(UT)-- Characteristic440V/120min- safe failure
Operating temperature -40C ~ +80C
Operating state /Fault indicationGreen/Red
Number of ports1
Cross-section area (min)1.5mm² solid/Flexible
Cross-section area (max)35mm² stranded /25 mm² flexible
Mounting35mm DIN rails according to EN 60715
Enclosure materials Thermoplastic , UL94 V0
Place of installationIndoor installation
IP levelIP20
Approvals TUV
Weight232.5g
Installation Instructions

Selection of SPD:
For a power distribution system, the main characteristics used to define the lightning protection system and select a SPD to protect an electrical installation in a building are:

  • SPD
    • quantity of SPD
    • type
    • level of exposure to define the SPD's maximum discharge current Imax.
  • Short circuit protection device
    • maximum discharge current Imax;
    • short-circuit current Isc at the point of installation.

The other characteristics for selection of a SPD are predefined for an electrical installation.

  • number of poles in SPD;
  • voltage protection level Up;
  • operating voltage Uc.

This sub-section Design of the electrical installation protection system describes in greater detail the criteria for selection of the protection system according to the characteristics of the installation, the equipment to be protected and the environment.

Location and types of SPD:


Connection of SPD:
Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment.

The total length of SPD connections to the network and the earth terminal block should not exceed 50 cm.

 

                                    SPD in plastic enclosure                                                                             SPD in metal enclosure
 

 

 

RED: Replace
Once the indicator shows RED, the product must be replaced.
Company Profile

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$1.35 50 Pieces(MOQ)

Timelec IP65 Waterproof Plastic Distribution Box, UL94 V0 Industrial Electrical Enclosure, DIN Rail Mount Outdoor Junction Box

Taimu Electrical (Hangzhou)Co., Ltd.
$29.80 500 Pieces(MOQ)

Single Door Compact Distribution Board Metal Box for Efficient Wiring

Taimu Electrical (Hangzhou)Co., Ltd.
$5.90 60 Pieces(MOQ)

BCH8-63 4NO Modular Contactor, Household Voltage Contactor 63A 400V AC/DC Electronic Modular Contactor(AC 36V)

Taimu Electrical (Hangzhou)Co., Ltd.
$49.80 120 Pieces(MOQ)

Top selling mini 2P 32A 230V 50/60hz AFCI single 1P+N AFDD 20 amp Arc Fault Breaker Afci breaker

Taimu Electrical (Hangzhou)Co., Ltd.
$100.00 1 Piece(MOQ)

Cnkeeya 3kv - 36kv Polymeric Metal Oxide Surge Arrester for Distribution Lightning Arrester Apartarrayos ZnO Arrester Surge Protector

Zhejiang Hanya Electric Appliance Co., Ltd.
$40.00 1 Piece(MOQ)

class 3 6KA SPD surge protector device with LED light

FOSHAN FATECH ELECTRONIC TECHNOLOGY CO.,LTD
$3.90 500 Pieces(MOQ)

Konstar 110V Safe Electricity Under Over Surge Voltage Protector Basic Customization Automatic Voltage Protector

Longyear Electric Industrial Co. Ltd.
$3.80 500 Pieces(MOQ)

Konstar Wholesale Customized Conditioner Surge Voltage Protector High Quality Protector Voltage Protector

Longyear Electric Industrial Co. Ltd.
$20.00 100 Pieces(MOQ)

Polymer Housing Metal Oxide Surge Arrester

Yueqing Guoen Electrical Co., Ltd
$17.00 10 Pieces(MOQ)

DC SPD for Solar System Surge Protection Device Lighting Arrester Electrical Equipment 2pole 3p Power Strip Surge Protector Factory Price

Zhejiang THOR Electric Co., Ltd.