Timelec DC 2p 250V T1+T2 Industrial Protector Surge Arrester for Home

Price $9.00 Compare
Min Order 60 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 365 people viewed
Quantity
+-
 

Taimu Electrical (Hangzhou)Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
TMSPD7
Power Source Arrester
Zinc Oxide Arrester
Tandem Arrester
AC/DC System
Small
Low Voltage
Cuboid
PBT Fireproof
ROHS, ISO9001, CE
Timelec
275V / 255V
20kA
40kA
1.5kV
IEC61643-11
IP20
Class II, T2
Timelec, OEM / Private Label brands
Carton Box
18mm
China
853620
Product Description
Product Description

SPD Surge Protective Devices are designed to protect against transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousands of volts and can cause immediate or intermittent equipment failure. However, lightning and utility power anomalies only account for 20% of transient surges. The remaining 80% of surge activity is produced internally. Although these surges may be smaller in magnitude, they occur more frequently and with continuous exposure can degrade sensitive electronic equipment within the facility.


A power surge is a brief overvoltage event that can damage electrical devices and is a common cause for the failure of electrical equipment. Surges can damage and reduce the lifespan of:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

NEW 2020 National Electrical Code Requirements
All new and renovated homes are required to be protected by Listed and Approved Type 1 or Type 2 Surge Protective Devices.

Type 1:
Permanently connected Surge Protective Device.  Protects against external and internal surges. May be installed inside or outside the home.

Type 2:
Permanently connected Surge Protective Device installed in, or next to, breaker box. Protects again internal or external surges.

Type 3:
Extra protection. Point-of-use Surge Protective Device. Must be used in conjunction with Type 1 or Type 2 SPD to meet 2020 code requirements.

Use Type 1, 2, and 3 SPDs for the best level of protection.  
 

Product Parameters
SPD according to EN 61643-11/IEC61643-11Type 2/Class II
Energy coordination with terminal equipment (10m)Type 2+ Type 3
Nominal voltage (AC) (Un)230V (50/60Hz)
 MOV (Varistors)GDT (Spark gap)
Max. continuous operating voltage (AC) (Uc)275V (50/60Hz)255V (50/60Hz)
Nominal discharge current (8/20s) (In)20KA20KA
Max. discharge current (8/20s) (Imax)40KA40KA
Voltage protection level (L-PE)/(N-PE) (Up)1.5KV1.3KV
Response time (tA)25nS
Max. mains-side overcurrent protection125AgG
Short-circuit withstand capability for max. mains-side50KA
Overcurrent protection (ISccR)
Temporary overvoltage (TOV)(UT)-- Characteristic335V/5 Sec-- withstand
Temporary overvoltage (TOV)(UT)-- Characteristic440V/120min- safe failure
Operating temperature -40C ~ +80C
Operating state /Fault indicationGreen/Red
Number of ports1
Cross-section area (min)1.5mm² solid/Flexible
Cross-section area (max)35mm² stranded /25 mm² flexible
Mounting35mm DIN rails according to EN 60715
Enclosure materials Thermoplastic , UL94 V0
Place of installationIndoor installation
IP levelIP20
Approvals TUV
Weight232.5g
Installation Instructions

Selection of SPD:
For a power distribution system, the main characteristics used to define the lightning protection system and select a SPD to protect an electrical installation in a building are:

  • SPD
    • quantity of SPD
    • type
    • level of exposure to define the SPD's maximum discharge current Imax.
  • Short circuit protection device
    • maximum discharge current Imax;
    • short-circuit current Isc at the point of installation.

The other characteristics for selection of a SPD are predefined for an electrical installation.

  • number of poles in SPD;
  • voltage protection level Up;
  • operating voltage Uc.

This sub-section Design of the electrical installation protection system describes in greater detail the criteria for selection of the protection system according to the characteristics of the installation, the equipment to be protected and the environment.

Location and types of SPD:


Connection of SPD:
Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment.

The total length of SPD connections to the network and the earth terminal block should not exceed 50 cm.

 

                                    SPD in plastic enclosure                                                                             SPD in metal enclosure
 

 

 

RED: Replace
Once the indicator shows RED, the product must be replaced.
Company Profile

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$1.35 50 Pieces(MOQ)

Outdoor IP65 Plastic Distribution Box by Timelec, UV Resistant Waterproof Electrical Enclosure for Industrial Applications

Taimu Electrical (Hangzhou)Co., Ltd.
$11.99 120 Pieces(MOQ)

MCB over current protection curveC 100amp 4p 10ka miniature circuit breaker

Taimu Electrical (Hangzhou)Co., Ltd.
$1.32 120 Pieces(MOQ)

Main switch 125amp PV TMH1-125 Electric Switch 1P Disconnect

Taimu Electrical (Hangzhou)Co., Ltd.
$2.60 1200 Pieces(MOQ)

dc mcb solar miniature circuit breaker 20 amp 32amp 40amp 63amp 1p 2p 3p 4pole mini electrical breakers mcb

Taimu Electrical (Hangzhou)Co., Ltd.
$0.08 1000 Pieces(MOQ)

Gas Discharge Tube Gdt Kg2r05 for Communication Equipment

Shenzhen Kangtai Songlong Electronic Technology Co., Ltd.
$10.00 1000 Pieces(MOQ)

Special Terminal 34s Varistor Equal to Epcos

Guangdong Foshan Kestar Electronic Co., Ltd.
$2.70 100 Pieces(MOQ)

Sollatek Voltage Switcher Surge Protector AVS 30AMPS

Yueqing Baoge Electric Co., Ltd.
$5.80 500 Pieces(MOQ)

Konstar 220V Ex Works Appliances Electronic Automatic Fridge Guard with Power Cord Voltage Protector

Longyear Electric Industrial Co. Ltd.
$6.00 100 Pieces(MOQ)

High-Power Discharge Tube Gdt Surge Arrester

Ningbo Zhengmao Electronics Co., Ltd.
$11.00 1 Piece(MOQ)

Yh10W-192, 192kv 10ka Electrical Surge Arrester

ORIENT ELECTRIC INTERNATIONAL GROUP LIMITED