| Liebert EXL Specifications | ||||||
| TECHNICAL SPECIFICATIONS | ||||||
| UPS Rating kVA) 300 400 500 600 800 1000 1200 | ||||||
| INPUT | ||||||
| Nominal mains input voltage / voltage range* (V) | 400 (200 to 460), 3Ph or 3Ph + N | |||||
| Nominal bypass input voltage / voltage range* (V) | 50±10%(60 selectable) | |||||
| Nominal frequency / frequency tolerance (Hz) | ≥0.99 | |||||
| Nominal bypass input voltage / voltage range* (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | |||||
| Nominal frequency / frequency tolerance (Hz) | 50±10%(60 selectable) | |||||
| Input Power Factor | ≥ 0.99 | |||||
| Input current distortion (THDi) (%) | ≤3 | |||||
| OUTPUT | ||||||
| Nominal output voltage (V) | 400 (380/415 selectable), 3Ph or 3Ph + N | |||||
| Nominal output frequency (Hz) | 50 (60 selectable) | |||||
| Output voltage stability by load variation 0-100% (%) static dynamic | ±1 | |||||
| Complies with IEC/EN 62040-3, Class 1 | ||||||
| Output frequency stability synchronized with bypass mains synchronized with internal clock (%) | ±2 (2, 3, 4, 5 selectable) | |||||
| ±0.1 | ||||||
| Inverter Overload Capacity* | 110% continuous, 125% for 10mins, 150% for 1min | |||||
| Output PF* | up to 1 | |||||
| Inverter Overload Capacity* | 110% continuous, 125% for 10mins, 150% for 1min | |||||
| Output PF* | up to 1 | |||||
| Load crest factor handled without derating the ups (Ipk/Irms) | 3:01 | |||||
| Compatibility with loads | Any power factor (leading or lagging) up to 1 | |||||
| BATTERY | ||||||
| Permissible battery voltage range (V) | 396 to 700 | |||||
| Float voltage for VRLA @ 20 °C (V/cell) | 2,27 | |||||
| End cell voltage for VRLA (V/cell) | 1.65 | |||||
| Float Voltage stability in steady state condition (%) | ≤1 | |||||
| DC ripple voltage without battery (%) | ≤1 | |||||
| Battery Switch | Not included | |||||
| BAPASS | ||||||
| Manual Maintenance Bypass | 50 (60 selectable) | Included 100-500 kW | Not included 600-1200 kW | |||
| CENERAL AND SYSTEM DATA | ||||||
| Classification according to IEC/EN 62040-3 | VFI-SS-111 | |||||
| Operating Temperature (°C) | 0-40 | |||||
| Maximum relative humidity @ 20 °C (non condensing) (%) | up to 95 | |||||
| Protection degree with open doors | IP 20 | |||||
| Frame colour (RAL scale) | 7021 | |||||
| Noise @ 1 metre as per ISO 3746 (dBA ± 2dBA) | 69 | 71 | 76 | 78 | ||
| 6 5 dBA @partial load | 70 dBA @partial load | 72 dBA @partial load | ||||
| Parallel configuration | Parallel configuration | |||||
| Access | Front and Top (no rear access required) | |||||
| AC/AC efficiency: VFI according to IEC/EN 62040 definition (%) VFD according to IEC/EN 62040 definition (%) | up to 97% up to 99% | |||||
| DIMAENSION AND WEIGHT | ||||||
| Height (mm) | 1950 | |||||
| Width (mm) | 1000 | 1250 | 2000 | 2650Net Weight (kg) | ||
| Net Weight (kg) | 900 | |||||
| Net Weight (kg) | 725 | 990 | 1550 | 2275 | ||























1. May I take some samples to test before I placing the order?Yes, we can offer sample testing for you to verify product quality and performance.
2. What is the warranty?
We support 1 years warranty.
3.What can you buy from us?
Eaton, Vertiv, APC, Santak, Vesion & OEM/ODM UPS; Cooling, MDC, PDU and so on.
4. What payment methods does your conmpany support?
We could accept T/T, credit card, Alipay or L/C at sight.
5. What are the terms can you offer for us?
We could offer EXW, FOB, CIF, DDP and so on.








Audited Supplier