VFP-S Series Single Phase Variable Frequency AC Power Supply |
- Power range: 500VA ~ 200KVA
- Voltage range: 0 ~ 150Vac / 150 ~ 300Vac
- 45Hz ~ 70Hz variable output frequency, 50 / 60 / 100 / 200Hz static output frequency.
- Precise voltage and current setting and measurement capabilities
- Small size, high efficiency and low energy consumption.
- OVP, OCP, OTP and short circuit protections etc.
|  |
Overview |  |
The VFP-S series is single-phase output model which has various output range from 500VA to 200KVA, it has high resolution & stability and full protection functions, output voltage & frequency continuously adjustable and easy operation-panel. It's widely used as a simulated AC input for equipment or home appliance testing. |
Block diagram |
 |
Features |
- Output voltage & frequency adjustable via potentiometer or key button
- Output Range: Voltage - Low level: 0 ~ 150V, High level: 150 ~ 300V or 0 ~ 300V continuously adjustable (best simulate input voltage of different countries)
- Frequency: 45 ~ 70Hz (adjustable)
50Hz / 60Hz / 100Hz / 200Hz / 400Hz (fixed) - Power: 500VA ~ 200KVA for selection.
- High output voltage accuracy and output frequency stability
- Response time: 2ms
- 0.5% load stability.
- ±1.5% waveform distortion (resistive load)
- High-accuracy display for output voltage, current, frequency, power & power factor.
- Full Protection functions (over voltage, over load, over temp, over current, short-circuit)
- Friendly Operation Panel.
|
Optional functions |
- 0 ~ 5V / 0 ~ 10V / 4 ~ 20mA analog signal control. (DB port) (+AC)
- RS communication interface (RS232 / RS485 optional) (+RC)
|
Application |
- For electron-products testing, debugging, powering for electro-instrument
- Electromotor, electron manufacturing, IT industry, computer, labs and so on.
- Other situations that need frequency conversion power supply
|
Specifications |
Output capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 100KVA | 120KVA | 150KVA | 200KVA |
Circuit mode | IGBT/PWM pulsing width modulating mode |
AC input | Single-phase 220Vac / 50Hz, 60Hz | Three-phase 380Vac / 50Hz, 60Hz |
AC output | Phase | Single-phase |
Voltage | Low level | 0.0~150V (special requirements can be customized) |
High level | 150.0~300V (special requirements can be customized) |
Frequency | 45~70Hz (adjustable) 50Hz, 60Hz, 100Hz, 200Hz, 400Hz (fixed) (special requirements can be customized) |
Max. Current | 0 ~ 150Vac | 4.2A | 8.4A | 16.8A | 25A | 42A | 50A | 84A | 125A | 168A | 250A | 375A | 500A | 834A | 1000A | 1250A | 1667A |
150 ~ 300Vac | 2.1A | 4.2A | 8.4A | 12.5A | 21A | 25A | 42A | 63A | 84A | 125A | 188A | 250A | 417A | 500A | 625A | 834A |
Frequency Stability | ≤±0.1% |
Load Stability | ±0.5% |
Harmonic distortion | ≤1.5% (resistive load) |
Response time | ≤2ms |
Output display | Voltage, Current, Power, Frequency & Power factor all 4-digit LED display. |
Display resolution | Voltage meter: 0.1V Current meter: less than 4A: 0.001A more than 4A: 0.01A Power meter: less than 200W: 0.1W more than 200W: 1W Frequency meter: 0.1Hz Power factor: 0.001 (optional) |
Protections | Auto tripping and alarm when over voltage, over load, over temp, over current and short-circuit. (Input & output no fusing breaker) |
Cooling mode | Forced air-cooling |
Working Temperature | 0°C~45°C |
Relative humidity | 0 ~ 90% (non-condensing) |
Size (W*H*D) (mm) | 430*180*440 | 430*180*470 | 430*520*650 | 550*520*740 | 580*820*1060 | 700*1020*1205 | 800*1450*1205 | 1000*1600*1450 |
Weight (Kg) | 26 | 32 | 37 | 48 | 63 | 80 | 145 | 175 | 285 | 385 | 420 | 560 | 960 | 1150 | 1450 | 1900 |
The product can be customized on demand. |
Maintenance |
- Check whether the bolts or moisture loosen regularly
- Check whether water leakage at pipe connection regularly
- Check whether any leaking of water pipe connection regularly.
- Regularly open the box side plate, cleaning dust inside.
- Regularly with clip-on ammeter check three-phase input current that it is abnormal and serious drift phenomenon, if abnormal, contact the supplier in time.
- Specially assigned person for equipment maintenance.
|
Installation environment |
- Ambient temperature: Please have the power source working in safe temperature range (0ºC ~ 45ºC) or it would affect life of power source.
- Please install the power source at least 50cm distant from surroundings to have better ventilation.
- Please install the power source away from vibration (less than 0.6G), especially equipment like puncher.
- Keep the power source away from direct sunshine, humidity or place with water globule.
- Keep the power source from corrosive, flammable & explosive gas.
- Keep the power source away from oil stain, dust & metallic dust.
|