Yund Surge Protective Device Circuit Breaker

Price $9.00 Compare
Min Order 10 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 436 people viewed
Quantity
+-
 

Elecal Electric Appliance Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
YUND-40
Low Voltage Circuit Breakers
Manual Type
Normal Type Circuit Breaker
Air
Fixed
MCCB
3
Circuit Breaker
Circuit-Breaker Failure Protection
ISO9001-2000, CE, CB, CCC
ELECAL
Carton
Wenzhou
Product Description
Usage and application scope
YUND type SPD is series surge protective device (protector in short) is applied in A.C 50/60 Hz , ≤380V electric power system such as TT,IT ,TN-S,TN-C and TN-C-S, and used at the equipotential connection of LPZ0A and LPZ31 zone or LPZ0B and LPZ1 zone, which protects the electric network shocked by the thunder or surge over voltage. 
The protector can be made connecting with remote signaling contact, which is a normal open contact. If one or more of modular of the protector is in malfuction, the contact will be closed, and sending the malfunction signal. The rated value of remote signaling contact is AC36V,1A. 
Maximum continuous operating voltage:                              Uc 320, 385VAC
test classification:                                                                II grade 
voltage protection level:                                                       uP< 2.0 2.5 3.0 kV
max. discharging current (8/20s):                                     Imax 60 80 100kA
Nominal discharge current (8/20s):                                   In 30 40 60kA
Model and meaning

Note: combination mode: 3-3 pole combination, public pole connects to the earth. 
3-3 pole combination, public pole connects to N 
pole combination, public pole connects to the earth
Main Structure and Operating Principle
In three-phase four- line system , three phase lines and one zero line are connected protective device to the earth cable . (figure 1 ) . In normal situation , the protective device is high resistance , when the over voltage brings for electric network shocked by thunder or other reasons , the protective device will rapidly transmit in ns , then lead the voltage into earth and protect the electric equipment . As the surge voltage through the protective device and after disappear it will recover to high resistance and not influence the normal operating.
 
Technical Parameters
Item
YUND-60/3-385
YUND-60/3N-385 
YUND-60/4-385
YUND-80/3-385 
YUND-80/3N-385
YUND-80/4-385
YUND-100/3-385
YUND-100/3N-385
YUND-100/4-385
Maximum continuous operating voltage Uc
385 V
Test grade
Class 2
Nominal discharge current In(8/20s)
30kV
40kV
60kV
Maximum discharge current Imax (8/20s) kA
60kV
80kV
100kV
Voltage protective level Up
2.0 kV
2.5 kV
3.0 kV
Response time ns
< 25 ns
 
Defending grade
IP20
 
Ambient temperature
-40---- +85C
Color ( Mould )
Orange
( Base )
Grey
Outer covering material
Reinforced fire-retardant nylon PBT
Phase Line , Zero Line
6 ----3 5mm2
Earth Line
6 ----3 5mm2
Signal Line
1.5 mm2
Accessory
According to the needs adding the remote signaling contact
 
Item
YUND-60/3-320 
YUND-60/3N-320
YUND-60/4-320
YUND-80/3-320
YUND-80/3N-320 
YUND-80/4-320
YUND-100/3-320 
YUND-100/3N-320
YUND-100/4-320
Maximum continuous operating voltage Uc
320 V
Test grade
Class 2
Nominal discharge current In(8/20s)
30kV
40kV
60kV
Maximum discharge current Imax (8/20s)
60kV
80kV
100kV
Voltage protective level Up
2.0 kV
2.0 kV
2.5 kV
Response time ns
< 25 ns
 
Defending grade
IP20
 
Ambient temperature
-40---- +85C
Color ( Mould )
Orange
( Base )
Grey
Outer covering material
Reinforced fire-retardant nylon PBT
Phase Line , Zero Line
6 ----3 5mm2
Earth Line
6 ----3 5mm2
Signal Line
1.5 mm2
Accessory
According to the needs adding the remote signaling contact
Installation position and application
A1. SPD class B, functioning as an equi-potential connection in case of lightning.
2. Installed at the joint of the LPZOA, LZPOB and LPZ1 zones.
3. It is usually installed in low voltage main distribution cabinet connected to the incoming end of the buildings.
4. It adopts 35 mm DIN rail.
5. It is linked by 6 --- 35 mm2 copper wire
6. The cable should choose double color wire which is longer than 6 mm2 
7.. In order to guarantee electrical network's normal operating after protective device losing efficiency , the protective device which linked to the phase line must be connected a fuse box whose current is higher than 63A or a circuit breaker.ppearance and Installation Dimension

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$16.60 1 Piece(MOQ)

Austand Distribution Box with Single Door (30ways)

Elecal Electric Appliance Co., Ltd.
$0.90 1 Piece(MOQ)

Dz60-63 Series Miniature Circuit Breaker

Elecal Electric Appliance Co., Ltd.
$9.00 10 Pieces(MOQ)

Yund Surge Protective Device Circuit Breaker

Elecal Electric Appliance Co., Ltd.
$1000.00 1 Piece(MOQ)

SVC-D (LCD) Series Fully Automatic a. C. Voltage Regulator

Elecal Electric Appliance Co., Ltd.
$200.00 1 Piece(MOQ)

Operating Mechanisms for High Voltage Circuit Breakers and Load Switches with Spring-Assisted Technology

Jliamigo Electric Power (Yueqing) Co., Ltd.
$720.00 1 Piece(MOQ)

Indoor Zn63-24 Vs1 24kv High Voltage Hv Vcb 630A 17.5kv Fixed Type Vacuum Circuit Breaker Vcb

Shengsu Electric Co., Ltd.
$1.80 10 Pieces(MOQ)

High Quality Chint 2p MCCB Nxb-63 Circuit Breaker

ANSHAN XBHY TRADING CO., LTD.
$8.50 100 Pieces(MOQ)

Siyan MCCB Breaker 380V Sym1-63A-3p Vacuum Circuit Breaker

Zhejiang Siyan Electric Technology Co., Ltd
$19.50 100 Pieces(MOQ)

3vs1600 Motor Protection Circuit Breaker, 3vu1640 Motor Protection Circuit Breaer; 3vs1600 Motor Protection Device, Motor Protector

Yueqing Lifang Electric Co., Ltd.
$750.00 1 Piece(MOQ)

10kv 24kv 33kv Vcb/Vacuum Circuit Breaker Vd4/210mm Vcb 10kv/Draw-out Type/Modular

Wenzhou Mingzhe Electric Co., Ltd.