Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

16mm2 4 Core PVC Insulation and Sheath Swa Armoured Cable Cu Electrical Wire

Price $5.00
Min Order 1 Meter
Availability In Stock
Shipping From Tianjin, China
Popularity 252 people viewed
Model NO.:
N2XRY/YJV32
Application:
Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car, to Be Fixedly Laid Indoors, in Tunnel
Voltage:
Low and Medium Voltage Cable
Current:
DC & AC
Insulation Material:
XLPE/PVC
Sheath Material:
PE/PVC
Material Shape:
Round Wire
Wire Core Material:
Copper or Aluminum
Certification:
ISO, CCC, CE, RoHS, VDE
Model:
Yjv32
Brand:
Feiya
Temperature Range:
-5 Degree Till +70 Degree
OEM&ODM:
Yes
Rated Voltage:
0.6/1kv
Operating Environment:
Underground
Material:
PVC/PE Jacket
Other Service:
Can Be Customized
Use Place:
Power Transmission and Distribution
Lowsmokezerohalogan:
LSZH, Lsoh, Ls0h, Lsfh, Ohls
Colors:
Can Be Customized
Trademark:
Feiya
Transport Package:
Wooden Box Packing or Pallet Shipping Containers
Specification:
copper/aluminum/pvc
Origin:
China
HS Code:
8544
Product Description
0.6/1kV Copper/Aluminum PVC/XLPE Insulation Power Cable





Cable structure

  • Stranded bare copper conductor according to IEC 60228
  • Core insulation of XLPE (cross-linked polyethylene)
  • Color coded cores according to HD 308.S2
  • PVC inner sheath
  • Armouring of steel wires (SWA)
  • Outer black sheath, PVC self-extinguishing and flame retardant, test method IEC 60332-1 and BS 4066 PT1

Technical data

  • Power and control cable according to BS 5467, IEC 60502
  • Temperature at conductor: max. +90°C,
  • Temperature during installation: 0°C to +70°C,
  • Nominal voltage Uo/U 0,6/1 kV
  • Test voltage a.c. 4 kV
  • Minimum bending radius 8 x cable diameter

Application

These power and control armoured cables are designed for open air installation, for direct burrial underground, in water, in cable ducts, power stations, for industry and distribution boards or subscriber networks, where mechanical damages to the cable may occur.

 

1000V Armored Cable Technical data sheet
 

No. x mm2PhaseNeutral/EarthInner sheathArmoredOuter sheathWeight of Cable
Diameter of conductor  mmThickness of XLPE  mmDiameter of conductor  mmThickness of XLPE  mmThickness  mmDiameter of wire
mm
Thickness of Sheath  mmComplete Diameter mmYJV32(CU)
kg/km
YJLV32(AL)
kg/km
1*1.51.380.7--10.81.810143.8134.5
1*2.51.780.7--10.81.810.4162.4146.9
1*42.250.7--10.81.810.9187162.2
1*62.760.7--10.81.811.4216.3178.9
1*1040.7--10.81.812.6278.7216.1
1*165.10.7--10.81.813.7353255.5
1*256.30.9--10.81.815.3471.7319.2
1*3570.9--10.81.816574.4361.9
1*508.21--11.251.818.3768.2480.8
1*70101.1--11.251.820.31014592.2
1*9511.61.1--11.251.821.91284704.1
1*120131.2--11.61.824.21601.8870.7
1*15014.61.4--11.61.826.21931.31019
1*18516.21.6--11.61.828.22320.11182.8
1*24018.41.7--11.61.930.82900.71426
1*30020.61.8--11.61.933.235091665.6
1*40023.82--1.222.138.44628.72216.6
1*50026.62.2--1.222.241.85708.82646.8
1*630302.4--1.222.345.871253206.9
1*800342.6--1.42.52.5529119.44132.8
2*1.51.380.7--10.81.813.2319.2300.4
2*2.51.780.7--10.81.814364.6333.4
2*42.250.7--10.81.814.9425.3375.3
2*62.760.7--10.81.815.9493.4418.2
2*1040.7--11.251.819.3794.4668.6
2*165.10.7--11.251.821.5991.4795.5
2*256.30.9--11.61.825.41452.41145.9
2*354.60.9--11.61.8221461.61034.6
2*505.51--11.61.824.21790.91213.1
2*706.31.1--11.6226.62319.31471.5
2*957.51.1--1.222.130.43157.21991.6
2*1208.41.2--1.222.232.837582288.4
2*1509.31.4--1.222.335.64482.42648.7
2*18510.21.6--1.42.52.5405723.13437.1
2*24012.51.7--1.42.52.745.471454180.8
2*30013.91.8--1.62.52.849.28583.14877.9
3*1.51.380.7--10.81.813.6351.2323
3*2.51.780.7--10.81.814.5408.3361.4
3*42.250.7--10.81.815.5484.8409.9
3*62.760.7--10.81.816.6577.9465.1
3*1040.7--11.251.820.2928.8740.1
3*165.10.7--11.251.822.51188.5894.6
3*256.30.9--11.61.826.71760.71301
3*355.40.9--11.61.824.41914.61274.1
3*506.81--11.61.9282439.61572.9
3*7081.1--1.22232.33483.62211.9
3*959.51.1--1.222.235.94401.82653.4
3*12010.81.2--1.222.339.35265.63061.2
3*15012.11.4--1.42.52.544.66844.34093.6
3*18513.51.6--1.42.52.648.681394710
3*24015.41.7--1.62.52.853.910086.75640.4
3*300171.8--1.62.5358.112085.36527.4
4*1.51.380.7--10.81.814.3391.3353.7
4*2.51.780.7--10.81.815.3459.7397.2
4*42.250.7--10.81.816.4551.7451.8
4*62.760.7--11.251.818.6800.7650.4
4*1040.7--11.251.821.61089.3837.6
4*165.10.7--11.61.824.915431151.1
4*256.30.9--11.61.828.82094.71481.8
4*356.20.9--11.61.92723861531.9
4*507.61--11.6230.73014.11858.5
4*708.81.1--1.222.235.44298.92603.3
4*9510.51.1--1.222.339.35480.43149.3
4*12011.21.2--1.42.52.543.16972.24033.1
4*150131.4--1.42.52.648.28452.24784.6
4*18514.51.6--1.62.52.853.110276.85704.9
4*24016.21.7--1.62.5357.712650.16721.6
4*300191.8--1.62.53.264.715397.17986.5
5*1.51.380.71.380.710.81.815.1431384
5*2.51.780.71.780.710.81.816.2518.9440.7
5*42.250.72.250.711.251.818.4762.6637.7
5*62.760.72.760.711.251.819.7909.8722
5*1040.740.711.251.823.11245.8931.2
5*165.10.75.10.711.61.826.81797.51307.6
5*256.30.96.30.911.61.831.12444.21678
5*3570.970.911.61.933.22988.71921.1
5*508.218.211.222.138.54106.22661.7
5*705.11.1101.11.222.338.251293009.5
5*956.21.111.61.11.42.52.443.66956.44042.5
5*1206.61.2131.21.42.52.646.88317.74643.9
5*1507.61.414.61.41.62.52.852.410163.55579
5*1858.51.616.21.61.62.5357.412320.86605.8
5*2409.61.718.41.71.62.53.262.815266.77856.1
5*30010.81.820.61.81.83.153.470.119366.510103.3
3*2.5+1*1.51.780.71.380.710.81.815.1442.9386.6
3*4+1*2.52.250.71.780.710.81.816.1527.8437.3
3*6+1*42.760.72.250.711.251.818.3776.2638.6
3*10+1*640.72.760.711.251.820.81014787.7
3*16+1*105.10.740.711.251.823.61322.2965.4
3*25+1*166.30.95.10.711.61.827.81953.61395.9
3*35+1*166.70.95.10.711.61.828.82295.11556.6
3*50+1*257.416.30.911.61.931.12847.61827.7
3*70+1*358.71.170.91.222.136.24015.52530.3
3*95+1*5010.51.18.211.222.240.55076.73039.4
3*120+1*7011.61.2101.11.222.443.96227.13598.8
3*150+1*70131.4101.11.42.52.549.77816.54641.9
3*185+1*9514.51.611.61.11.42.52.754.59503.85492.1
3*240+1*12016.51.7131.21.62.52.960.411746.46565.3
3*300+1*15018.81.814.61.41.62.5366.3141267651.2
3*2.5+2*1.51.780.71.380.710.81.815.8484.5418.8
3*4+2*2.52.250.71.780.711.251.817.8702.1596
3*6+2*42.760.72.250.711.251.819.2853.3690.7
3*10+2*640.72.760.711.251.821.71110846.1
3*16+2*105.10.740.711.61.825.61635.81216.1
3*25+2*166.30.95.10.711.61.829.32182.11526.4
3*35+2*166.50.95.10.711.61.829.12453.21616.7
3*50+2*257.416.30.911.6232.23125.61952.5
3*70+2*3591.170.91.222.137.94482.42783.7
3*95+2*5010.71.18.211.222.342.45679.23353.1
3*120+2*70121.2101.11.42.52.547.87499.74447.5
3*150+2*7013.41.4101.11.42.52.652.38649.75051.2
3*185+2*95151.611.61.11.62.52.857.910681.16086.6
3*240+2*120171.7131.21.62.5363.613074.77158.8
3*300+2*15019.21.814.61.41.62.53.269.715769.38377.6
4*2.5+1*1.51.780.71.380.710.81.816501.6429.7
4*4+1*2.52.250.71.780.711.251.818.1732.4616.9
4*6+1*42.760.72.250.711.251.819.5888.2713
4*10+1*640.72.760.711.251.822.41172.6883.3
4*16+1*105.10.740.711.61.826.21716.51261.7
4*25+1*166.30.95.10.711.61.830.22304.31593.4
4*35+1*1670.95.10.711.61.931.92748.91796.8
4*50+1*254.916.30.91.222.130.33418.12109.3
4*70+1*356.21.170.91.222.236.84720.12811
4*95+1*507.51.18.211.222.441.26035.13415.1
4*120+1*707.91.2101.11.42.52.54678224459
4*150+1*709.21.4101.11.42.52.749.89267.45175.9
4*185+1*9510.51.611.61.11.62.52.955.611326.36171.6
4*240+1*12012.81.7131.21.62.53.162.614109.67446.4
4*300+1*150151.814.61.41.83.153.371.518037.89710.3


Look for customised cables? Get more information connect with Daisy

 

  











Q1: Are you a trading company or manufacturer? 

A1: Tianjin Feiya wire & Cable Co., Ltd. is a professional manufacturer

Q2: What kinds of products does Tianjin Feiya wire & Cable Co., LtdManufacture? 

A2: Our products mainly cover low, medium and high voltage (KV) crosslinked polyethylene insulated power cable, PVC insulated power cable, PVC insulated wire (construction cable), control cable, signal cable, rubber cable, coal mine cable, welding cable, ship cable and other related customized cables. These cables are used in Power metallurgy, Oil&Chemical Industry, Nation Defense Power Station, Mine, Port and Architectural Engineering, andother fields. 

Q3: Which standards do you comply with when you produce the electrical wires and cables? 

A3: We have passed ISO9001: 2000 and ISO140001: 2004. All products conform to GB, IEC, BS, ASTM, VDE JB and UL standards. Besides, we have the ability to design and produce various wires and cables, and customize them for you according to the special requirements of customers (providing OEM services). 

Q4: What is your MOQ
A4: It`s base on the cable type or wire type. Please contact Calder. He will let you know. 

Q5: How much the Courier freight will be for the samples? 

A5: Courier freight depends on the quantity, weight and carton size and your area.  
 

  • Similar Products
Full Page Contact Supplier