$18.50
2000 Pieces (MOQ)
BLDC Motor/Fan Blower Motor
TAISHAN JIANGKOU ELECTRIC APPLIANCE MANUFACTORY LTD.
Swipe or use the arrows to view product images.
5kw 8kw 21000rpm Pmsm High Speed High Efficiency Electric Synchronous Motor
| Price | $2000.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Guangdong, China |
| Popularity | 364 people viewed |
Model NO.:
SRPM112H4W5
Application:
Industrial, Power Tools, Fans, Pumps, Compressors
Operating Speed:
High Speed
Operation Mode:
Electric Motor
Magnetic Structure:
Permanent Magnet
Function:
Driving
Structure:
Rotating Pole Type (Armature Fixed)
Number of Poles:
8
Ventilation:
Closed
Certification:
ISO9001, CE, RoHS
Brand:
Mc-Motor
Usage:
Fans, Pumps, Compressors, Blower
Net Weight:
10kg
Efficiency:
94.7%
Rated Power:
5kw
Rated Speed:
21000rpm
Cooling Method:
Water Cooled
Power Range:
1-10kw
Speed Range:
12000rpm-21000rpm
Duty Type:
S1
IP Level:
IP54.IP65
Insolution:
H/F
Trademark:
mc motor
Transport Package:
1PC/ Carton ( Wood /Paper Box Optional)
Specification:
TBD (based on real motor dimension)
Origin:
China
HS Code:
8501520000
Product Description
3kw 5kw 8kw 21000rpm Pmsm Synchronous High Speed High Efficiency Electric Motor Water Cooling Product Feature
1.Suitable for the 12000---21000rpm rated speed
2.High power & high torque
3.High efficiency
4.Small size
5.Low noise low vibration
6.Patented cooling structure
7.Easy maintenance and long life time
8.Durable, reliable
Specifications
Model type:SRPM112H4W5
Voltage: 380V AC
Rated Power:1-10KW
Rated speed: 20000rpm--24000rpm
Isolation: H/F
Water/dust Proof: IP54(IP67 option)
Cooling Method: Water
Installation Method: B35
Application
High-speed Compressors,Fans,Pumps
Main Motor Range
The Case for the Projects
Other motors you will be interested in
1. Can performanent magnet synchronous motor be used as generator?
Yes. Permanent magnet synchronous motor can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation
1.Suitable for the 12000---21000rpm rated speed
2.High power & high torque
3.High efficiency
4.Small size
5.Low noise low vibration
6.Patented cooling structure
7.Easy maintenance and long life time
8.Durable, reliable
Specifications
Model type:SRPM112H4W5
Voltage: 380V AC
Rated Power:1-10KW
Rated speed: 20000rpm--24000rpm
Isolation: H/F
Water/dust Proof: IP54(IP67 option)
Cooling Method: Water
Installation Method: B35
Application
High-speed Compressors,Fans,Pumps
Main Motor Range
The Case for the Projects
| Motor type | Voltage | Rated power | Rated torque (N.m) | Rated speed | Efficiency | Insulation | Ingress protection | Pole Number | PIC | Weight | Cooling Method | Position Signal | Duty Type | Installation Method |
| (V AC) | (kW) | (rpm) | (%) | (kg) | ||||||||||
| SPRM( General) | 380 | 5.5-110 | 10-420 | 10000-80000 | 95.00% | H/F | IP54/IP67 | 8 | 19-112 | Water | Resolver | S1-S9 | B35 | |
| SPRM( General) | 380 | 4-37 | 35-463 | 15000-24000 | 95.00% | H/F | IP54/IP67 | 8 | 14-100 | Air | N/A | S1-S9 | B35 | |
| SPRM( General) | 380 | 37-350 | 35-463 | 12000-24000 | 95.00% | H/F | IP54/IP67 | 8 | 14-25 | Oil | N/A | S1-S9 | B35 | |
| SRPM112H4F7.5C | 380 | 7.5 | 3.4 | 21000 | 95 | H/F | IP54 | 4 | 12 | Air | N/A | S1-S9 | B35 | |
| SRPM112H4F7.5C | 380 | 7.5 | 3 | 24000 | 95 | H/F | IP54 | 4 | 12 | Air | N/A | S1-S9 | B35 | |
| SRPM112H4F15F | 380 | 15 | 6 | 24000 | 95 | H/F | IP54 | 4 | 20 | Air | N/A | S1-S9 | B35 | |
| SRPM112H4F18.5 | 380 | 18.5 | 8.41 | 21000 | 95 | H/F | IP54 | 4 | 25 | Air | N/A | S1-S9 | B35 | |
| SRPM180L8F18.5 | 380 | 18.5 | 33.3 | 5300 | 95 | H/F | IP54 | 8 | 25 | Air | N/A | S1-S9 | B35 | |
| SRPM130H4F22 | 380 | 22 | 10 | 21000 | 95 | H/F | IP54 | 4 | 33 | Air | N/A | S1-S9 | B35 | |
| SRPM130H4F37 | 380 | 37 | 19.63 | 18000 | 95 | H/F | IP54 | 4 | 47 | Air | N/A | S1-S9 | B35 | |
| SRPM168H2F75C | 380 | 75 | 21.07 | 34000 | 95 | H/F | IP54 | 2 | 50 | Air | N/A | S1-S9 | B35 | |
| SRPM112H4F15 | 380 | 15 | 5.96 | 24000 | 96.5 | H/F | IP54 | 4 | 12 | Air/Water | N/A | S1-S9 | B35 | |
| SRPM112H4W5.5 | 380 | 10 | 2.5 | 21000 | 94 | H/F | IP67 | 4 | 14 | Water | N/A | S1-S9 | B35 | |
| SRPM112H4W10 | 380 | 10 | 8 | 12000 | 94 | H/F | IP67 | 4 | 20 | Water | N/A | S1-S9 | B35 | |
| SRPM112H4W20 | 380 | 20 | 8 | 24000 | 96.5 | H/F | IP54 | 4 | 25 | Water | N/A | S1-S9 | B35 | |
| SRPM112H4W22B | 380 | 22 | 8.75 | 24000 | 96.5 | H/F | IP54 | 4 | 25 | Water | N/A | S1-S9 | B35 | |
| SRPM112H4W25 | 380 | 25 | 15.9 | 15000 | 96.5 | H/F | IP54 | 4 | 28 | Water | N/A | S1-S9 | B35 | |
| SRPM112H4W30 | 380 | 30 | 17.9 | 16000 | 96.5 | H/F | IP54 | 4 | 32 | Water | N/A | S1-S9 | B35 | |
| SRPM210M4W55B | 380 | 55 | 52.5 | 10000 | 95.4 | H/F | IP54 | 4 | 55 | Water | N/A | S1-S9 | B35 | |
| SRPM210H4W60 | 380 | 60 | 45.8 | 12500 | 96.5 | H/F | IP54 | 4 | 80 | Water | N/A | S1-S9 | B35 | |
| SRPM210M4W75C | 380 | 75 | 71.6 | 10000 | 96.5 | H/F | IP54 | 4 | 95 | Water | N/A | S1-S9 | B35,V1 | |
| SRPM130H4W20 | 380 | 20 | 3.3 | 60000 | 95.00% | H/F | IP54/IP67 | 4 | 45 | Water | N/A | S1-S9 | B35 | |
| SRPM95H2W18 | 380 | 18 | 0.667 | 75000 | 95.00% | H/F | IP54/IP67 | 2 | 45 | Water | N/A | S1-S9 | B35 | |
| SRPM95H2W5.5 | 380 | 5.5 | 2.29 | 80000 | 95.00% | H/F | IP54/IP67 | 2 | 25 | Water | N/A | S1-S9 | B35 | |
| SRPM180M8O30 | 380 | 30 | 23.8 | 12000 | 96.5 | H/F | IP67 | 8 | 12 | Water/Oil | N/A | S1-S9 | B35 | |
| SRPM165H4XO37 | 380 | 37 | 17.7 | 20000 | 96.50% | H/F | IP54/IP67 | 4 | 100 | Oil | N/A | S1-S9 | B35 | |
| SRPM214H4O50 | 380 | 50 | 19.9 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 100 | Oil | N/A | S1-S9 | B35 | |
| SRPM214H4O75 | 380 | 75 | 29.8 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 120 | Oil | N/A | S1-S9 | B35 | |
| SRPM214H4O100 | 380 | 100 | 39.8 | 24000 | 95.00% | H/F | IP54/IP67 | 4 | 150 | Oil | N/A | S1-S9 | B35 | |
| SRPM214H4O124 | 380 | 124 | 66 | 18000 | 95.00% | H/F | IP54/IP67 | 4 | 250 | Oil | N/A | S1-S9 | B35 | |
| SRPM160H4XO90 | 380 | 90 | 43 | 20000 | 96.5 | H/F | IP67 | 4 | 48 | Oil | N/A | S1-S9 | B35 | |
| SRPM205H4XO110 | 380 | 110 | 52.5 | 20000 | 96.5 | H/F | IP67 | 4 | 76 | Oil | N/A | S1-S9 | B35 | |
| SRPM205H4XO160 | 380 | 160 | 76.4 | 20000 | 96.5 | H/F | IP67 | 4 | 86 | Oil | N/A | S1-S9 | B35 | |
| SRPM205H4XO200 | 380 | 200 | 95.5 | 15500 | 95.5 | H/F | IP67 | 4 | 350 | Oil | N/A | S1-S9 | B35 | |
| SRPM205H4O220 | 380 | 200 | 131.1 | 16000 | 95.5 | H/F | IP67 | 4 | 310 | Oil | N/A | S1-S9 | B35 | |
| SRPM290H4O350 | 380 | 350 | 167.1 | 20000 | 95.5 | H/F | IP67 | 4 | 530 | Oil | N/A | S1-S9 | B35 |
Other motors you will be interested in
| Motor type | Voltage (V AC) | Rated power (kW) | Rated torque (N.m) | Rated speed (rpm) | Efficiency (%) | Service Factor | Insulation | Ingress protection | Pole Number | Weight (kg) | Cooling Method | Position Signal | Installation Method |
| SRPM151M8XW11 | 380 | 11 | 11 | 9600 | 96 | S1 | H/F | IP67 | 8 | 10 | Oil circulation | Resolver | B35 |
| SRPM205M8XO45 | 380 | 45 | 36 | 12000 | 96.3 | S1 | H/F | IP67 | 8 | 35 | Oil circulation | Resolver | B35 |
| SRPM205M8XO55 | 380 | 55 | 43.8 | 12000 | 96.3 | S1 | H/F | IP67 | 8 | 38 | Oil circulation | Resolver | B35 |
| SRPM205M8XO75 | 380 | 75 | 59.7 | 12000 | 96.5 | S1 | H/F | IP67 | 8 | 43 | Oil circulation | Resolver | B35 |
| SRPM205M8XO90 | 380 | 90 | 71.6 | 12000 | 96.5 | S1 | H/F | IP67 | 8 | 47 | Oil circulation | Resolver | B35 |
| SRPM205M8XO110 | 380 | 110 | 87.6 | 12000 | 96.5 | S1 | H/F | IP67 | 8 | 75 | Oil circulation | Resolver | B35 |
| SRPM205M8XO132 | 380 | 132 | 105 | 12000 | 96.5 | S1 | H/F | IP67 | 8 | 80 | Oil circulation | Resolver | B35 |
| SRPM205M8XO160 | 380 | 160 | 127.3 | 12000 | 96.5 | S1 | H/F | IP67 | 8 | 87 | Oil circulation | Resolver | B35 |
| SRPM205M8XO185 | 380 | 185 | 147.2 | 12000 | 96.5 | S1 | H/F | IP67 | 8 | 95 | Oil circulation | Resolver | B35 |
1. Can performanent magnet synchronous motor be used as generator?
Yes. Permanent magnet synchronous motor can work as a generator because of its special working theory. If it runs CW as a motor, then runs CCW as a generator. But please kindly note, if when you want to work it as a generator, you need to change a suitable motor controller with AFE function
2. Why can not directly use three phase ac supply voltage to start permanent magnet synchronous motor?
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed.
3. Any special technical request on this motor's VFD driver? And Do you have such driver?
Permanent magnet synchronous motor's driver should be vector control VFD with special inner software, such as Siemens 6SE70 series, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 series, etc.. Yes, our MH300 series VFD matches with this motor.
4. Is there any protective measures to defend permanent magnet rotor from failure?
Yes, each permanent magnet rotor passes corrossion resistance, consistency, high temperature demagnetization test, linear demagnetization test, etc. Its demagnetization index is within 2%. But if working environment is serious oxiditive corrosion, kindly advise for higher protection level.
5. Where is this permanent magnet synchronous motor normally used to?
This permanent magnet synchronous motor is normally used to variable frequency speed situation
- Similar Products
$20000.00
1 Piece (MOQ)
1.9MW Electric Motor Synchronous Motor 60Hz
Shanghai Pinnxun Electric Motor Co., Ltd.
$12.00
100 Pieces (MOQ)
24V 110V 220V Synchronous Zone Valve Electric Motor
Zhejiang Hengsen Industry Group Co., Ltd.