A216 Wcb DN20-DN300 · Flange According to GB/T9113-2000 Self-Regulating Pressure Control Valve with Pilot Operation Capability

Price $800.00
Min Order 1 Piece
Availability In Stock
Shipping From Shandong, China
Popularity 439 people viewed
Model NO.:
AOC-3112
Temperature:
Ordinary Temperature
Certification:
GS, CE, ISO9001
Media:
Gas, Oil, Water, Acid
Standard:
Standard
Connection Mode:
Flange
Power:
Pneumatic
Material:
Stainless Steel
Type:
Self-Operated
Nominal Diameter(DN):
20-300
Length of The Receiver Tube (B):
383-2200
Flange Face Distance L(Pn16/25/40):
150-850
Flange Face Distance L(Pn64):
230-900
Pn16 Weight as an Example:
26-675
Flow Character:
Quick-Open
Body Mat.:
A216wcb
Seat Mat.:
316ss+Stl
Stem Mat.:
316ss+Solution Treatment
Packing:
PTFE
Bonnet Type:
Bellows
Effective Area:
1000 Cm2
Temperature Range:
-20 Degree~250 Degree
Allowable Leakage:
Class IV (Hard Seal)/Class VI (Soft Seal)
Flange Standard:
GB/T9113-2000/Jb/T79.1-94/Jb/T79.2-94/ Hg2059
Trademark:
SNT
Transport Package:
Wooden
Origin:
China
HS Code:
8481804090
Product Description
 

Product Description


The AOC-3112 Model Self-Operated Pressure Regulator Valve with Pilot (hereinafter referred to as the Pressure Valve) does not require an external energy source. It utilizes the energy of the regulated medium as the power source, introducing the pilot of the Pressure Valve to control the position of the valve core, thereby adjusting the flow rate of the medium through the valve. This ensures that the downstream pressure (Type B) or upstream pressure (Type K) remains constant. Type B is primarily used when the upstream pressure is relatively high (0.2-0.8 MPa) and the downstream pressure is very low (0.5-100 KPa), such as in cases of 50 mmH2O (water column). Type K is used exclusively in nitrogen purging systems and is compatible with nitrogen supply systems.

Structure Features

1. The pressure setting is accomplished on the pilot, making it convenient, quick, labor-saving, and time-efficient, with the capability of continuous adjustment during operation. It boasts high control accuracy, making it suitable for applications requiring high precision control.
2. For the same valve, the adjustment range is broader compared to an ordinary self-operated valve.

3. It is particularly sensitive, capable of detecting very small pressures (such as a pressure of 50 mm H2O) or minimal pressure changes.
4. The pressure reduction ratio is exceptionally large; for example, with an upstream pressure of 0.8 MPa and a downstream pressure of 50 mm H2O, the pressure differential ratio reaches 1600.

For applications of other products (self-operated micro-pressure regulator valve, self-operated differential pressure regulator valve, self-operated temperature regulator valve, self-operated flow regulator valve, self-operated liquid level regulator valve), please contact the SNT Technical Department.

 

Product Parameters


Nominal diameter(DN)20253240506580100125150200250300
Length of the receiver tube (B)38351260386210231380180020002200
Flange face distance L(PN16,25,40)150160180200230290310350400480600730850
Flange face distance L(PN64)230260300340380430500550650775900

Pressure adjustment range
KPa
15~140H475520540710780840880940950
A280308
120~300H455500520690760800870900950
A230
280~500H450490510680750790860890940
A176194280
480~1000H445480670740780780850880930
A176194280

PN16 Weight (Kg)
PN16 as an example
2637427290112130169285495675

   

Product Materials

 
Part nameMaterials

Valve body
A216 WCB,A351 CF8/CF3/CF8M/CF3M,ZG230-450,ZG0Cr18Ni9Ti,ZG0Cr18Ni12Mo2Ti

Spool
304SS,316SS,304LSS,316LSS,1Cr18Ni9,  0Cr18Ni12Mo2Ti
(Stellite Clad welding Stellite)   PTFE

Valve seat
304SS,316SS,304LSS,316LSS,1Cr18Ni9,0Cr18Ni12Mo2Ti (Stellite Clad welding Stellite)
Stem304SS,316SS,304LSS,316LSS,1Cr18Ni9,1Cr18Ni9,0Cr18Ni12Mo2Ti   
Rubber diaphragmNitrile,ethylene,fluoro,oil resistant rubber ,0Cr18Ni9Ti
Membrane cover  Q235,Q235 Painting PTFE

Packing
  
Polytetrafluoroethylene,flexible graphite

Pressure adjustment method


The self-regulating pressure valve is factory adjusted to the set value, but if the user wants to change the set value, or if for some reason the actual indication value deviates from the set value, the pressure can be lowered by turning the adjusting bar with the turning piece 7 (adjusting disc) in the clockwise direction and the pressure increased by turning it in the counterclockwise direction.
 

Valve Maintenance

Trouble shootingCauses of productionExclusion methods
Unstable post-valve pressure with1,Spool stuck by foreign objects
2,Valve stem, push rod jammed
3,Fluid inlet pipe blocked

1,Reinstallation to exclude foreign objects
2,Re-adjustment
3,unclogging
,pressure changes in front of the valve
1,Set spring stiffness is too large
2,The valve bore is too large
3,The pressure before the valve is too high, the pressure reduction ratio is too large

1,Replacement of springs
2,Replace the smaller diameter
3,The pressure before the valve and the pressure after the valve exceed 20, should be 2 levels of pressure reduction
Pressure behind the valve does not drop, always above the demand value
1,Set spring stiffness is too small
2,The valve bore is too small
3,The pressure reduction ratio is too small

1,Replacement of springs
2,Replace the larger diameter
3,Pressure before the valve: the pressure after the valve is lower than 1.25, the pressure before the valve should be increased
Pressure behind the valve does not rise, always below the demand value1Set spring stiffness is too small
2,The spool is stuck by a foreign object
3,Valve stem, push rod jammed
4,The spool and seat are damaged, the leakage is too large
5,The valve bore is too large

1,Replacement of springs
2,Reinstallation
3,Re-adjustment
4,Re-grind, or replace
5,Replace smaller diameter
Pressure behind the valve does not rise and always moves below the demand value1 Set spring stiffness is too large
2,The valve bore is too small
3,The spool, stem, push rod, etc. are stuck

1,Replacement of springs
2,Replace larger diameter
3,Exclude the cause of jamming and readjust
Pre-valve pressure does not drop, always moves above the demand value
1,The valve bore is too large
2,Actuator membrane chamber capacity is too small
Select the proper valve diameter
2,Add a damper in the inlet pipeline
 
     

Instructions for Ordering

Valve type Valve name 
Nominal diameter (mm)Nominal pressure (Mpa)
Pressure adjustment range (Mpa) Control valve before or after
Pressure setting value (Mpa)Name of medium
Actuator type Medium working temperature
Rated flow coefficient Medium state
Max. pressure before valve
Minimum pressure before valve
Normal pressure before the valve(Mpa)
Max. pressure after valve
Min. pressure after valve
Normal pressure after valve (Mpa)
Maximum flow rate
Minimum flow rate
Normal flow rate
 Viscosity of liquids
Liquid density
Gas density
 
Material:Valve body
Valve internals
 Leakage level requirements
(GB/T4213-92)
 
Process piping dimensionsCorrosion resistance requirements 
Flange face distance (mm) L Flange execution standards 
Supplied with accessoriesCondenser, receiver, mating flange, fasteners, regulator bar, pressure take-off tube, pressure take-off fitting


 

Production application

 


 
 