Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

ASTM G154 Laboratory UV Accelerated Weathering Test Equipment

Price $3999.00
Min Order 1 Piece
Availability In Stock
Shipping From Guangdong, China
Popularity 545 people viewed
Model NO.:
BND-HZW
After-sales Service:
Good
Power Supply:
110V 220V 380V
Warranty:
1 Year
Warranty:
1 Year
After-Sales Service:
Good
Power Supply:
110V 220V 380V
Certification:
ISO
Type:
UV Aging Chambaer
Temperature Range:
Rt+10~70°c
Humidity Range:
Humidity Range
Wavelength Ultraviolet Light:
280~315nm
Delivery Time:
3-7days
Product Name:
UV Aging Test Chamber
Working Size:
W1165*D450*H500mm
Power Rate:
2.0kw
Place of Original:
Shenzhen China
Temperature Control:
Pid SSR Control
Material:
Stainless Steel
Structure:
Wall Mounted
Protection Level:
IP54
Voltage:
220V
Rated Load:
500~800kg
Trademark:
bnd
Transport Package:
Safety Wooden Box
Specification:
iso11507
Origin:
China
Product Description
ASTM G154 laboratory uv accelerated weathering test equipment


 
Introduction:
Accelerated Weather UV test machine is applicable for the sunlight resistant test of nonmetallic materials and aging test of artificial light sources. A variety of industrial products can make the reliability test, and this product can simulate the product in the sun, rain, humidity and dew conditions, including damage caused by bleaching, color, brightness down, powder, crack, blur, brittle, intensity decreased and oxidation.
 
 
Technical parameters:
 
Studio Size400W×1140D×390Hmm
Outside dimension500W×1300D×1360Hmm
MaterialsInside and Outside SUS#304 stainless steel 
Temperature rangeRT+10~70°C
Temperature uniformity±1°C
Temperature fluctuation±0.5°C
Temperature controlPID SSR control
Humidity range: ≥90%RH
ControllerKorean TEMI 880 programmable controller
Control modeBalance temperature humidity control (BTHC)
Test cycle settingIllumination, condensation and water spray test cycle is programmable
Lamp power40W/Piece
Distance from sample to lamp50±3mm (adjustable) 
Centre distance between the lamp70mm 
Irradiance1.0W/cm2
Wavelength ultraviolet lightUV-A: 315-400mm;  UV-B: 280-400mm (8pcs, 1600h lifetime)
Effective irradiation areas640×1140mm
Irradiation black panel temperature50°C~70°C
Standard Specimen Size75×290mm (24pcs can be tested each time)
Required water depth for water channel25mm, automatically control
Testing time0~999H, adjustable
Power220V/50Hz /±10% 5KW
Protection systemOverload short circuit protection, over temperature protection, water lackin
 
 
 
 
Chamber Structure:

The inner bladder of the chamber is made of imported high-class stainless steel plate while the outer bladder is made of SUS 304 steel plate.
The heating mode adopts inner bladder trough type heating with its rapid temperature rise and even temperature distribution.

 
 
Control System:
Adopts black aluminum plate to connect temperature sensor and adopts black board temperature meter to control heating so as to ensure more stable temperature.
 
The radiometer probe is fixed so as to avoid the frequent installation and disassembly.
The radiation quantity adopts the special UV irradiatometer with high-precision display and measurement.
 
The radiation intensity is not more than 50W/m2.
 
The illumination and condensation can be controlled independently or alternating and circularly.


 
 
 
Test Specimen Mounting:
The standard test specimen holder accommodates 2 panels 75×150mm. The test panels are actual the side wall of the chamber. To properly seal the chamber, it is important to have every panel holder filled with specimens or blank panels and to have panel holders in place.
 
 
 
Design criteria:
(1) ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings
 
(2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)
 
(3) ISO 4892-1: Plastics - Methods of Exposure to Laboratory Light Sources - Part 1: General guidance
 
(4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps
 
(5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics
 
(6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure
 
(7) ASTM D5208: Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics
 
(8) IEC 61345: UV Test for Photovaltalic (PV) Modules



What about your quality?
Each equipment must be carry out 100% examination and test again before shipping
What is the MOQ ?
Most instruments support MOQ one set.
How long the delivery time ?
Generally most equipment will be 3-10days after we receive your payment or the order conformed ,please conform with us before you made an order .
What is the warranty of the products?
One year ,but we can provide you life long support .
What is the package?
Export standard Solid wooden case
What is the shipping way ?
We have stable forwarding agent for air and sea transportation ,and also express about DHL TNT etc , we will suggest you the best shipping way base on your requirement .
What is the payment term ?
T/T, Western Union,Money gram ,Paypal etc

 

Company  Profile :Our  Advantages :
Certifications :Factory  Introduction :Plant Warehouse :Cooperative Customers & Brands:
Customer  Reviews :
Product  Packaging :

  • Similar Products
Full Page Contact Supplier