Swipe or use the arrows to view product images.
Automatic Controlled Coal Water Mixture Steam and Hot Water Series Boiler (Mixed Fuel Boiler) Power Plant EPC
| Price | $200000.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Shandong, China |
| Popularity | 437 people viewed |
Model NO.:
SZS, YSL, YSW, SHF, SHFS
Function:
Steam Boilers, Hot Water Boiler
Fuel:
Coal Water Mixture
Installation:
Assembled Boiler
Structure:
Fire Tube
Media:
Steam or Hot Water
Water Circulation:
Natural Circulation
Drum Placement:
Vertical Boiler
Pressure:
Low and Medium Temperature and Pressure
Manufacturing Level:
A
Burning Style:
Chamber Combustion Boiler
Usage:
Industrial
Optional Pressure:
0.7/1.0/1.25/1.6/3.82
Gas Flow Type:
Fire Tube and Water Tube
Certification:
SGS, Ce,ASME
Control System:
PLC Optional
Transport Package:
Exported Standard/According to Requirement; FCL
Specification:
SGS, CE, ASME
Origin:
China
HS Code:
84021900
Product Description
1. The clean fuel, manufactured by premium fuel, shall solve the pollution problem at the source.
2. The problems of high running cost for oil fired boiler shall be settled.
3. The product features environmental protection and energy-saving. Sulfer and dust contained in the flue gas and other environmental protection indexes shall surpass national standard.
4. Burn-out rate shall be more than 98 percent, and thermal efficiency shall be up to 85 percent or more.
5. Coal water mixture shall be transported and stored in liquid state. It shall be ignited automatically, with being automatic controlled easily, so it is the perfect substitude for oil fired boiler on environmental protection and energy-saving.
| Boiler type Items | SZS2-1.25-J | SZS4-1.25-J | SZS6-1.25-J | SZS10-1.25-J |
| Rated output(t/h) | 2 | 4 | 6 | 10 |
| Rated working pressure (Mpa) | 1.25 | 1.25 | 1.25 | 1.25 |
| steam temperature °c | saturated | saturated | saturated | saturated |
| Feedwater temperature °c | 20 | 105 | 105 | 105 |
| combustion mode | Chamber combustion | Chamber combustion | Chamber combustion | Chamber combustion |
| Applicable fuel | Coal water mixture | Coal water mixture | Coal water mixture | Coal water mixture |
| Maximum weight of transportation cargo (t) | 31.5 | 35.5 | 45 | BULK |
| Maximum size of transportation cargo (L×W×H)mm | 6300×3100×3540 | 7100×3400×3540 | 8700×3800×3600 | 14850×7800×10450 |
| If main product capability parameter noted is changed,you shall refer to the technical documents on delivery. | ||||
| Boiler type Items | YSL-700J | YSL-1050J | YSW-2800J |
| Thermal output(MW) | 0.7(60) | 1.05(90) | 2.8(240) |
| Rated working pressure (Mpa) | 0.7 | 0.7 | 1 |
| The fuel consumption at full load operation(kg/h) | 180 | 270 | 720 |
| Rated working temperature (°c) | ≤300 | ≤300 | ≤300 |
| The circulation oil volume(m3) | 51 | 76 | 163 |
| Overall dimension (lengthxwidthxheight)mm | 2740×2350×3290 | 3250×2360×3590 | 6900×2720×3460 |
| Total weight of equipments(t) | 17.5 | 21.5 | 36 |
| If main product capability parameter noted is changed,you shall refer to the technical documents on delivery. | |||
| Boiler type Items | YSW-4200-J | YSW-7000-J | YSW-14000-J |
| Thermal output(MW) | 4.2(360) | 7.0(600) | 14.0(1200) |
| Rated working pressure (Mpa) | 1 | 1 | 1 |
| The fuel consumption at full load operation(kg/h) | 1080 | 1800 | 3600 |
| Heating area(m2) | 271 | 350.3 | 735 |
| Rated working temperature (°c) | ≤300 | ≤325 | ≤325 |
| The circulation oil volume(m3) | 244 | 360 | 650 |
| Overall dimension (lengthxwidthxheight)mm | 8350×2900×3460 | 9700×3300×6460 | 17300×8550×11000 |
| Total weight of equipments (t) | 48 | 87.5 | 177.5 |
| Boiler type Items | SHFS4-1.25-J | SHFS6-1.25-J | SHFS10-1.25-J | SHFS20-1.6-SM | SHFS35-3.82/450-SM | SHFS75-3.82/450-SM |
| Rated output(t/h) | 4 | 6 | 10 | 20 | 35 | 75 |
| Rated working pressure (Mpa) | 1.25 | 1.25 | 1.25 | 1.6 | 3.82 | 3.82 |
| Steam temperature °c | saturated | saturated | saturated | saturated | saturated | saturated |
| Rated feedwater temperature °c | 20 | 105 | 105 | 105 | 105 | 105 |
| Combustion mode | Fluidization suspension combustion | Fluidization suspension combustion | Fluidization suspension combustion | Fluidization suspension combustion | Fluidization suspension combustion | Fluidization suspension combustion |
| Applicable fuel | Coal water mixture(CWM) | Coal water mixture(CWM) | Coal water mixture(CWM) | Coal water mixture(CWM) | Coal water mixture(CWM) | Coal water mixture(CWM) |
| Maximum elevation of boiler proper(mm) | 6000 | 6300 | 6700 | 8000 | 11100 | 14000 |
| Overall dimension of installation for boiler proper(LxWxH)mm | 8300×6800×6000 | 8500×6800×6300 | 10670×7550×6700 | 12650×7950×8000 | 15280×7950×11100 | 18100×1050×14000 |
| Boiler type Items | SHFS2.8-1.0/115/70-J | SHFS4.2-1.0/115/70-J | SHFS7.0-1.0/115/70-J | SHFS14.0-1.0/115/70-J | SHFS29.0-1.0/115/70-J |
| Rated thermal power(MW) | 2.8 | 4.2 | 7 | 14 | 29 |
| Rated working pressure (Mpa) | 1 | 1 | 1 | 1 | 1 |
| Rated effluent temperature °c | 115 | 115 | 115 | 115 | 115 |
| Rated return water pemperature °c | 70 | 70 | 70 | 70 | 70 |
| Combustion mode | Fluidization suspension combustion | Fluidization suspension combustion | Fluidization suspension combustion | Fluidization suspension combustion | Fluidization suspension combustion |
| Applicable fuel | Coal water mixture(CWM) | Coal water mixture(CWM) | Coal water mixture(CWM) | Coal water mixture(CWM) | Coal water mixture(CWM) |
| Maximum weight of transportation cargo(t) | 6000 | 6300 | 6800 | 8000 | 11100 |
| Overall dimension of installation for boiler proper(LxWxH)mm | 8300×6800×6000 | 8500×6800×6300 | 15280×6950×6800 | 126507850×8000 | 15300×8050×11100 |
- Similar Products