2. The installation of imported brand burner resulted in the following advantages: fuel burning abundantly, obvious effect of energy-saving, and meeting the environmental requirements.
3. The application of totally enclosed combustion shall make the boiler room to be tasteless, noiseless, unpolluted, beautifull, and clean.
4. Compact structure, small floor area, and simple installation shall characterize the boiler.
CWN series automatic oil(gas)atmospheric pressure hot water boiler | |||
Boiler type Items | CWNS 0.35-95/70-Y(Q) | CWNS 0.7-95/70-Y(Q) | CWNS 1.4-95/70-Y(Q) |
Rated thermal power(MW) | 0.35 | 0.7 | 1.4 |
Rated working pressure (Mpa) | Atmospheric pressure | Atmospheric pressure | Atmospheric pressure |
Rated effluent water temperature °c | 95 | 95 | 95 |
Rated return water temperature°c | 70 | 70 | 70 |
Heating surface area(m2) | 17.5 | 37 | 79 |
Design fuel | Oil or Gas | Oil or Gas | Oil or Gas |
Fuel consumption(kg/h) | <32.53> | <65> | <125> |
Burner | Import | Import | Import |
WNS/SZS series automatic oil(gas) hot water boiler | ||||||
Boiler type Items | WNS 0.35-0.7/95/70-Y(Q) | WNS 0.7-0.7/95/70-Y(Q) | WNS 1.4-0.7/95/70-Y(Q) | WNS 2.8-0.7/95/70-Y(Q) | WNS 4.2-0.7/95/70-Y(Q) | SZS 7-1.0/95/70-Y(Q) |
Rated thermal power(MW) | 0.35 | 0.7 | 1.4 | 2.8 | 4.2 | 7 |
Rated working pressure (Mpa) | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 1 |
Rated effluent water temperature °c | 95 | 95 | 95 | 95 | 95 | 115 |
Rated return water temperature°c | 70 | 70 | 70 | 70 | 70 | 70 |
Heating surface area(m2) | 17.5 | 28.08 | 59.13 | 111.2 | 166.7 | 377.5 |
Design fuel | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil |
Fuel consumption(kg/h) | 33.9 | 66.3 | 127 | 252 | 377 | 621 |
Burner | Import | Import | Import | Import | Import | Import |
SZS series automatic oil(gas) steam boiler | |||||
Boiler type Items | SZS 2-1.25-Y(Q) | SZS 4-1.25-Y(Q) | SZS 6-1.25Y(Q) | SZS 10-1.25Y(Q) | SZS 20-1.25Y(Q) |
Rated output(t/h) | 2 | 4 | 6 | 10 | 20 |
Rated working pressure (Mpa) | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 |
Feedwater temperature °c | 20 | 20 | 20 | 105 | 105 |
Steam temperature °c | 194 | 194 | 194 | 194 | 194 |
Boil heating surface area(m2) | 68.8 | 125.3 | 165.1 | 210 | 435.2 |
Economizer heating surface(m2) | 18.48 | 37 | 49.28 | 144 | 236 |
Design fuel | Coke oven gas | Coke oven gas | Coke oven gas | Coke oven gas | Coke oven gas |
Fuel consumption(kg/h) | 347.5 | 684.5 | 1034.57 | 1474.4 | 2984.4 |
Burner | Import | Import | Import | Import | Import |
Main performance parameters of WNS/LNS series automatic oil(gas) steam boiler | ||||||||
Boiler type Items | WNS 0.5-1.0-Y(Q) | WNS 1-1.0-Y(Q) | WNS 2-1.0-Y(Q) | WNS 2-1.25-Y(Q) | WNS 4-1.25-Y(Q) | WNS 6-1.25-Y(Q) | LNS 0.2-0.7-Y(Q) | LNS 0.35-0.7-Y(Q) |
Rated output(t/h) | 0.5 | 1 | 2 | 2 | 2 | 6 | 0.2 | 0.35 |
Rated working pressure (Mpa) | 1 | 1 | 1 | 1.25 | 1.25 | 1.25 | 0.7 | 0.7 |
Feedwater temperature °c | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
Steam temperature °c | 184 | 184 | 184 | 194 | 194 | 194 | 170 | 170 |
Boil heating surface area(m2) | 14.3 | 28.08 | 59.13 | 58.3 | 105 | 166.7 | 6.22 | 9.51 |
Design fuel | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil | Light diesel oil |
Fuel consumption(kg/h) | 37.6 | 73.4 | 143 | 143 | 283 | 424 | 14.1 | 23 |
Burner | Import | Import | Import | Import | Import | Import | Import | Import |