Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Battery Pack Seawater Immersion Testing Device Lithium Saltwater Soaking Quality Assurance Tester

Price $50000.00
Min Order 1 Piece
Availability In Stock
Shipping From Guangdong, China
Popularity 362 people viewed
Model NO.:
MBS-HS1000
After-sales Service:
Support Operation Guidance
Power Supply:
380V
Certification:
CE
Warranty:
1 Year
City:
Dongguan, Guangdong
Uses:
Seawater Immersion Testing Device
Purpose:
Seawater Soaking Testing Machine
Customize:
Acceptable
Trademark:
MENTEK
Transport Package:
Wooden Box
Specification:
170*150*250cm
Origin:
China
HS Code:
9031809090
Product Description
Battery Pack Seawater Immersion Testing Device Lithium Saltwater Soaking Quality Assurance Tester
Product Description

Relevant Standard Testing Requirements
Safety Test for Single Batteries: The Heating Test shall be carried out in accordance with the following steps:

1.1 Charge the single battery according to the method specified in 6.1.3.

1.2 Place the single battery in a temperature chamber. For lithium-ion batteries, the temperature of the temperature chamber shall be increased from room temperature to 130°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 30 minutes before stopping the heating. For nickel-metal cyanide batteries, the temperature of the temperature chamber shall be increased from room temperature to 85°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 2 hours before stopping the heating. Observe for 1 hour.

Safety Test for Battery Modules: The Heating Test shall be carried out in accordance with the following steps:

1.1.1 Charge the batteries in the battery module according to the method specified in 6.1.4.

1.1.2 For lithium-ion batteries, the temperature of the temperature chamber shall be increased from room temperature to 130°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 30 minutes before stopping the heating. For nickel-metal cyanide batteries, the temperature of the temperature chamber shall be increased from room temperature to 85°C ± 2°C at a rate of 5°C/min, and maintain this temperature for 2 hours before stopping the heating. Observe for 1 hour.
 



Main Parameters

ModelMBS-HS1000
The size of the water tank W*H*D mm1000*1000*1000
Water tank materialPPR Plate welding
Equipment size W*H*D mm1700*1500*2500
Discharge waterAutomatic water discharge
Stirring systemInternal circulation of corrosion-resistant water pump
Product test methodCylinder lifting
The total weight of the equipment800kg
Equipment power supplyAC380V 5.5kW
Note: The dimensions can be meticulously tailored to match your specific requirements.