Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

DC 10-300V / 0-100A Battery Discharging Tester Lead Acid Battery Capacity Test DC Load Bank Wide Voltage with Cell Monitoring Model

Price $4400.00
Min Order 1 Piece
Availability In Stock
Shipping From Hubei, China
Popularity 272 people viewed
Model NO.:
HDGC3982-H8030050
After-sales Service:
1 Year
Warranty:
1 Year
Type:
Storage Battery Tester
Test Region:
Charge and Discharge
Application:
Lead-acid Battery
Customized:
Customized
Discharge Current:
0-100A/0-50A
Discharge Voltage:
DC10-300V
Display:
7 Inch Color LCD Display
Power Supply:
220V 45-65Hz
Suitable Battery:
10-300V Battery Group
PC Communication:
RS485 Interface, USB Interface
Temperature:
-5-50ºC
Net Weight:
18kg
Tester Size:
483*230*400
Safety:
Compliance with En610950
Package:
Woodel Box
Cooling:
Air Cooling
Communication:
RS 485 or USB
Brand:
HD Power
Optional Function:
Cell Battery Monitor
Trademark:
HD Power
Transport Package:
Wooden Box with Foam Inside
Origin:
Made in China
HS Code:
9030899090
Product Description
HDGC3982 Series Battery Discharging Tester(for10-300V Battery Group)
Type: HDGC3982-H8010620H8010630
Output
Discharge Voltage Range10~60V
Discharge Current Range0~200A0~300A
Output power≤12KW≤18KW
Group voltage resolution0.1V
Group voltage accuracy±0.5%FS+0.1V(Full scale)
Cell Voltage Measurement Range1.00V~16.00V,Resolution: 0.01V (the resolution can be accurate to 0.001V through the software view)
Cell Voltage Measurement Accuracy±0.1%FS
Current measurement accuracy±1%FS+0.1A(Full scale)
Battery capacity check range0~2000Ah0~3000Ah
Display
Display MaterialResistive Touchscreen
Display Mode7-Inch LCD true color, resolution: 1024*800
Working Mode&Data
Working modeSingle main unit / parallel master mode / parallel slave mode / remote controlled mode / Quick Test
Data storage capacityInternal: 16Gbit TF card
Data communicationRS485*3,USB*1,RF433
Protection Performance
Battery side protectionUnder-voltage, over-voltage, over-current, over-temperature, short-circuit, reverse connection protection
Audible and visual alarmReverse polarity, cut-off condition completion triggers LCD prompt, beep warning
Emergency stop protectionExternal open circuit breaker for emergency shutdown protection
Power Supply
VoltageSingle-phase3-Wire  AC220V (-20%-+30%), frequency: 45-65Hz;
Withstand voltageInput-shell: 2200Vdc 1min / Input-output: 2200Vdc 1min / Output-shell: 700Vdc 1min
Product Profile
HDGC3982 Battery Discharge Capacity Tester can be used as the discharge load in the battery off-line state to realize the constant discharge at the set value by regulating continuously the discharge current.
When discharging, the tester will automatically stop discharging when the voltage on the battery group terminal or the cell falls to the set lower limit value, or when the set discharging time is out, or when it reaches the set discharging capacity. Battery Discharge Tester can records all valuable and continuous real-time data during the discharge process.
Wide voltage series battery pack discharge capacity tester is specially developed independently for DC maintenance, covering multiple voltage battery pack maintenance, multi-purpose.
Product Features
1.Wide voltage and high current design: a single unit can fulfill the discharge test of battery packs with multiple voltage ranges. One machine is multi-purpose.
2.PTC ceramic resistor is adopted to avoid the red heat phenomenon for a safer discharge process .
3.Intelligent SCM ARM control, 7inch 1024*600 LCD screen , capacitive touch operation, built in  English menu, simple and clear operation menu.
4.Automaticself-protection stop function, over-heat protection ,over voltage protection , over current protection and reverse connection protection ,alarm prompt is displayed on the screen once it appears any issue, air circuit breaker automatically cut off .
5.It can set discharge terminationcondition including cell low voltage,whole group voltage low/high, charge current low, charge/discharge time , charge/discharge capacity .When any condition can be met, the instrument can stop automatically testing with buzz sound and record the stop reason at the same time.
6.Estimation of the remaining capacity of the battery by a quick discharge of 3-5 minutes .
7.Cell voltage wireless monitoring function, Compatible with 2V/6V/12V cell voltage monitoring,each wireless monitoring module can simultaneously monitor 12 cells.



 

 


  • Similar Products