Swipe or use the arrows to view product images.
Frt-Xsh Cu XLPE LSZH Swa LSZH Flame Retardant Armoured Cable
| Price | $39.80 |
|---|---|
| Min Order | 500 Meters |
| Availability | In Stock |
| Shipping From | Henan, China |
| Popularity | 541 people viewed |
Model NO.:
swa cable
Application:
Construction, Underground, Industrial, Power Station
Voltage:
Low and Medium Voltage Cable
Current:
AC Cable
Insulation Material:
XLPE
Sheath Material:
LSZH
Material Shape:
Round Wire
Wire Core Material:
Bare Copper Wire
Certification:
ISO, CCC, SGS
Model:
Armor Cable
Brand:
Hongda
Armoured:
Galvanized Steel Wire Armoured (Swa)
Outer Sheath:
Low-Smoke Zero-Halogen (LSZH)
Insulation Colour:
White with Black Numbering
Minimum Bending Radius (mm):
8 X Cable Overall Diameter
Trademark:
Hongda Cable
Transport Package:
Steel & Wooden Drum
Specification:
1.5mm2 to 4mm2
Origin:
China
HS Code:
8544492100
Product Description
FRT-XSH CU XLPE LSZH SWA LSZH Flame Retardant Armoured Cable
1. Overview
Low Voltage Power Cables, Aluminum and Copper conductors of voltage range:0.6/1.0 kV.
2. Cable Types
Copper Conductor Cables
Aluminium Conductor Cables
Thermoplastic/ PVC Insulated Cables
Thermoset/XLPE Insulated Cables
Armoured/ Non - Armoured Cables
Single core cables up to and including 1000 mm2
2 core cables up to and including 95 mm2
3, 4 core & 4 core with reduced neutral cables up to and including 500 mm2
3. Cables Include:
3.1.1 Cable construction
Conductor: Plain annealed copper, Class 2, Stranded circular or compacted
Insulation: Cross-linked Polyethylene (XLPE) compound
Insulation colour: White with Black numbering or Others
Assembly: Cores cabled together and bound with binder tape
Bedding: Low-Smoke Zero-Halogen (LSZH) compound
Bedding colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Black
3.1.2 Electrical Characteristics
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes
Dimensions - BS6724 XLPE/LSZH/SWA/LSZH (Copper)
Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Cables Notes
1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC , the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables must be used.
For more information, don't hesitate to call us or send inquiry to VIVIAN YUAN.
1. Overview
Low Voltage Power Cables, Aluminum and Copper conductors of voltage range:0.6/1.0 kV.
2. Cable Types
Copper Conductor Cables
Aluminium Conductor Cables
Thermoplastic/ PVC Insulated Cables
Thermoset/XLPE Insulated Cables
Armoured/ Non - Armoured Cables
Single core cables up to and including 1000 mm2
2 core cables up to and including 95 mm2
3, 4 core & 4 core with reduced neutral cables up to and including 500 mm2
3. Cables Include:
3.1.1 Cable construction
Conductor: Plain annealed copper, Class 2, Stranded circular or compacted
Insulation: Cross-linked Polyethylene (XLPE) compound
Insulation colour: White with Black numbering or Others
Assembly: Cores cabled together and bound with binder tape
Bedding: Low-Smoke Zero-Halogen (LSZH) compound
Bedding colour: Black
Armour: Galvanized Steel Wire Armoured (SWA)
Outer sheath: Low-Smoke Zero-Halogen (LSZH) compound with anti-termite characteristics and UV resistant
Outer sheath colour: Black
3.1.2 Electrical Characteristics
Operating voltage, U0/U: 600/1000V
Operating temperature: -15°C to +90°C
Final short circuit temperature: 250°C
Test Voltage: 3.5kV for 5 minutes
Dimensions - BS6724 XLPE/LSZH/SWA/LSZH (Copper)
Class 2 Stranded Conductors for Single Core and Multi-Core Cables
| No.of Cores and Nominal Conductor Area (mm2) | No. and Diameter of Wires (no./mm) | Radial Thickness of Insulation (mm) | Diameter Under Armour (mm) | Armour Wire Diameter (mm) | Cable Overall Diameter (mm) | Approximate Weight (kg/km) |
| 2 x 1.5 | 7/0.52 | 0.6 | 7.6 | 0.8 | 12.3 | 341 |
| 2 x 2.5 | 7/0.67 | 0.7 | 8.8 | 0.8 | 13.7 | 418 |
| 2 x 4 | 7/0.85 | 0.7 | 9.9 | 0.8 | 14.8 | 496 |
| 2 x 6 | 7/1.04 | 0.7 | 11.0 | 0.8 | 15.9 | 585 |
| 2 x 10 | 7/1.35 | 0.7 | 12.9 | 0.8 | 18.7 | 769 |
| 2 x 16 | 7/1.70 | 0.7 | 15.0 | 1.25 | 20.8 | 1081 |
| 2 x 25 | 7/2.13 | 0.9 | 18.4 | 1.6 | 25.1 | 1496 |
| 2 x 35 | 7/2.52 | 0.9 | 21.1 | 1.6 | 28.0 | 2014 |
| 2 x 50 (S) | 19/1.78 | 1.0 | 20.7 | 1.6 | 27.8 | 2135 |
| 2 x 70 (S) | 19/2.14 | 1.1 | 23.7 | 1.6 | 31.0 | 2728 |
| 2 x 95 (S) | 19/2.52 | 1.1 | 26.7 | 2.0 | 35.0 | 3642 |
| 2 x 120 (S) | 37/2.03 | 1.2 | 29.5 | 2.0 | 38.0 | 4341 |
| 2 x 150 (S) | 37/2.25 | 1.4 | 32.8 | 2.0 | 41.5 | 5117 |
| 2 x 185 (S) | 37/2.52 | 1.6 | 36.8 | 2.5 | 46.9 | 6574 |
| 2 x 240 (S) | 61/2.25 | 1.7 | 40.9 | 2.5 | 51.2 | 8025 |
| 2 x 300 (S) | 61/2.52 | 1.8 | 45.3 | 2.5 | 55.8 | 9596 |
| 3 x 1.5 | 7/0.52 | 0.6 | 8.0 | 0.8 | 12.7 | 375 |
| 3 x 2.5 | 7/0.67 | 0.7 | 9.4 | 0.8 | 14.3 | 463 |
| 3 x 4 | 7/0.85 | 0.7 | 10.5 | 0.8 | 15.4 | 556 |
| 3 x 6 | 7/1.04 | 0.7 | 11.8 | 0.8 | 16.7 | 669 |
| 3 x 10 | 7/1.35 | 0.7 | 13.8 | 1.25 | 19.6 | 981 |
| 3 x 16 | 7/1.70 | 0.7 | 16.1 | 1.25 | 22.1 | 1283 |
| 3 x 25 | 7/2.13 | 0.9 | 20.2 | 1.6 | 27.1 | 1959 |
| 3 x 35 | 7/2.52 | 0.9 | 22.6 | 1.6 | 29.7 | 2418 |
| 3 x 50 (S) | 19/1.78 | 1.0 | 23.3 | 1.6 | 30.4 | 2751 |
| 3 x 70 (S) | 19/2.14 | 1.1 | 27.0 | 1.6 | 35.1 | 3610 |
| 3 x 95 (S) | 19/2.52 | 1.1 | 30.9 | 1.6 | 39.4 | 4873 |
| 3 x 120 (S) | 37/2.03 | 1.2 | 33.9 | 2.0 | 42.6 | 5824 |
| 3 x 150 (S) | 37/2.25 | 1.4 | 38.1 | 2.5 | 48.0 | 7300 |
| 3 x 185 (S) | 37/2.52 | 1.6 | 42.9 | 2.5 | 53.0 | 8832 |
| 3 x 240 (S) | 61/2.25 | 1.7 | 48.0 | 2.5 | 58.5 | 10979 |
| 3 x 300 (S) | 61/2.52 | 1.8 | 52.3 | 2.5 | 63.0 | 13153 |
| 3 x 400 (S) | 61/2.85 | 2.0 | 60.8 | 2.5 | 71.9 | 16378 |
| 4 x 1.5 | 7/0.52 | 0.6 | 8.8 | 0.8 | 13.5 | 416 |
| 4 x 2.5 | 7/0.67 | 0.7 | 10.3 | 0.8 | 15.2 | 526 |
| 4 x 4 | 7/0.85 | 0.7 | 11.6 | 0.8 | 16.5 | 642 |
| 4 x 6 | 7/1.04 | 0.7 | 13.0 | 1.25 | 18.8 | 880 |
| 4 x 10 | 7/1.35 | 0.7 | 15.2 | 1.25 | 21.0 | 1156 |
| 4 x 16 | 7/1.70 | 0.7 | 17.8 | 1.25 | 24.5 | 1531 |
| 4 x 25 | 7/2.13 | 0.9 | 22.3 | 1.6 | 29.2 | 2335 |
| 4 x 35 | 7/2.52 | 0.9 | 25.1 | 1.6 | 32.2 | 2914 |
| 4 x 50 (S) | 19/1.78 | 1.0 | 25.3 | 1.6 | 32.6 | 3351 |
| 4 x 70 (S) | 19/2.14 | 1.1 | 29.7 | 2.0 | 38.2 | 4717 |
| 4 x 95 (S) | 19/2.52 | 1.1 | 33.4 | 2.0 | 42.1 | 5988 |
| 4 x 120 (S) | 37/2.03 | 1.2 | 37.2 | 2.5 | 47.1 | 7625 |
| 4 x 150 (S) | 37/2.25 | 1.4 | 42.7 | 2.5 | 52.8 | 9164 |
| 4 x 185 (S) | 37/2.52 | 1.6 | 47.3 | 2.5 | 57.8 | 11059 |
| 4 x 240 (S) | 61/2.25 | 1.7 | 54.6 | 2.5 | 65.3 | 13939 |
| 4 x 300 (S) | 61/2.52 | 1.8 | 60.5 | 2.5 | 71.6 | 16865 |
| 4 x 400 (S) | 61/2.85 | 2.0 | 69.7 | 3.15 | 82.7 | 21985 |
| 5 x 1.5 | 7/0.52 | 0.6 | 9.6 | 0.8 | 14.5 | 478 |
| 5 x 2.5 | 7/0.67 | 0.7 | 11.3 | 0.8 | 16.2 | 599 |
| 5 x 4 | 7/0.85 | 0.7 | 12.7 | 0.8 | 18.5 | 752 |
| 5 x 6 | 7/1.04 | 0.7 | 14.3 | 1.25 | 20.1 | 1007 |
| 5 x 10 | 7/1.35 | 0.7 | 16.8 | 1.251 | 22.8 | 1352 |
| 5 x 16 | 7/1.70 | 0.7 | 20.0 | 1.6 | 26.9 | 1977 |
| 5 x 25 | 7/2.13 | 0.9 | 24.7 | 1.6 | 31.8 | 2764 |
| 5 x 35 | 7/2.52 | 0.9 | 27.7 | 1.6 | 35.0 | 3456 |
| 5 x 50 | 19/1.78 | 1.0 | 32.7 | 2.0 | 41.0 | 4553 |
| 5 x 70 | 19/2.14 | 1.1 | 38.1 | 2.0 | 46.8 | 5961 |
Cables Notes
1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC , the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables must be used.
For more information, don't hesitate to call us or send inquiry to VIVIAN YUAN.
- Similar Products
Negotiable
100 Meters (MOQ)
Medium Voltage Copper-Aluminum Conductor XLPE Insulated Armored Electricity Cables
Foshan Jinfuyou Cable Co., Ltd
$28.77
1000 meters (MOQ)
High-Quality 4 Core 4*70mm2 PVC Insulation Ground Conductor Copper Cable
Ningbo Qrunning Cable Co., Ltd.
$999.00
1000 Meters (MOQ)
Multi Flexible Control Signal Control Cable 8X2.5mm 12X2.5mm
Henan Kingyear Aluminum Industrial Co., Ltd.