Negotiable
1 Piece (MOQ)
Compressed Hydrogen Dispenser Calibration Device
Chengdu Andisoon Measure Co. Ltd.
Swipe or use the arrows to view product images.
GF1061 CT PT Analyzer Machine Testing Block Procedure Distributor
| Price | $1.00 |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Beijing, China |
| Popularity | 591 people viewed |
Model NO.:
GF1061
After-sales Service:
24 Hour Service
Warranty:
36months
Application:
Thermal Power, Mechanical Instrument, Electromagnetic Instrument
Power:
Electricity
Certification:
FDA, CE, IAF, CCC
Voltage Output:
0-2500V
Current Output:
0-1000A
LCD Display:
With LCD Display
Customized:
Customized
Accuracy:
0.05%
Output Voltage:
0-100vrms
Output Current:
0-5arms (20A Peak-Value)
Output Power:
0-400 Va (1500 Vapeak)
Key Words:
CT PT Testing Procedure
Automatic Frequency Variation Range:
0.1-60Hz
Key Word:
CT PT Analyzer Distributor
Equivalent Excitation Voltage:
≤5000V
Model:
CT Test Machine
Color:
Grey
Trademark:
GFUVE
Transport Package:
Standard Export Box
Specification:
4kg
Origin:
Beijing, China
Product Description
product description
GF1061 high performance ct pt analyzer machine testing block procedure distributor is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Features
1. Steady and transient state characteristic tests of various types of CT/PT
2. The use of advanced power technology, the test knee point reaches up to 30kV
3. No external other auxiliary equipment, stand-alone to complete all test items
4. CT test, easy to test, all the tests are using the same wire connection except the load test
5. It carries with thermal printer, so it can print test results on site
6. Parameters such as knee point current and voltage
7. Parameters such as 10% error curve, 5% error curve
8. With battery, working 48hours.
9. The device can store 10000 groups of test data which would not be lost if the device is power off.
10. The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report
11. Portability: weight <4kg, the best light ct analyzer
Reference Standard
IEC 60044, ANSI/ IEEE C57.13, IEC61869, GB 1207-2006, GB 1208-2006
Parameters
Function
GF1061 high performance ct pt analyzer machine testing block procedure distributor is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Features
1. Steady and transient state characteristic tests of various types of CT/PT
2. The use of advanced power technology, the test knee point reaches up to 30kV
3. No external other auxiliary equipment, stand-alone to complete all test items
4. CT test, easy to test, all the tests are using the same wire connection except the load test
5. It carries with thermal printer, so it can print test results on site
6. Parameters such as knee point current and voltage
7. Parameters such as 10% error curve, 5% error curve
8. With battery, working 48hours.
9. The device can store 10000 groups of test data which would not be lost if the device is power off.
10. The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report
11. Portability: weight <4kg, the best light ct analyzer
Reference Standard
IEC 60044, ANSI/ IEEE C57.13, IEC61869, GB 1207-2006, GB 1208-2006
Parameters
| Electrical parameters | ||
|---|---|---|
| Accuracy | 0.05% | |
| Power supply | AC 220V±10% or AC 120V±10%, 50/60Hz or Battery | |
| Output voltage | 0-100Vrms | |
| Output current | 0-5Arms (20A peak-value) | |
| Output power | 0-400 VA (1500 VApeak) | |
| Automatic frequency variation range | 0.1-60Hz | |
| Equivalent excitation voltage | ≤5000V | |
| Accuracy | ≤0.5% | |
| Secondary winding DC resistance measurement | Range | 0.1-1000Ω |
| Accuracy | ≤0.05% | |
| Secondary actual load measurement | Range | 5VA-1000VA |
| Accuracy | ≤0.5%±0.1VA | |
| CT/PT phase error measurement | Accuracy | ±1min (typical) / 3 min (guaranteed) |
| Resolution | 0.1min | |
| CT ratio error measurement | Range | 1-50000 |
| Accuracy | ≤0.05% | |
| PT ratio error measurement | Range | 1-10000 |
| Accuracy | ≤0.05% | |
| Standards | ||
| Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13 | |
| Safety standards | GB 4793.1-2007 | |
| EMC | EMC standard 89/336/EEC | |
| FCC Subpart B of Part 15 Class A | ||
| IEC 1000-4-2 /3 /4 /6 | ||
| Mechanical parameters | ||
| Overall dimension (L x W x H) (mm) | 280 x 250 x 160 | |
| Weight (kg) | ≤4 | |
| Environmental conditions | ||
| Relative humidity | Relative humidity 5%-95% not condensing | |
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -20°C to +70°C | |
| Altitude | ≤1000m | |
| I. Current Transformer (CT) | II. Voltage Transformer (PT) |
|---|---|
| 1. Magnetization curve | 1. Excitation characteristic test |
| 2. Transformation ratio test | 2. Transformation ratio test |
| 3. Polarity | 3. Polarity |
| 4. 5% and 10% error curve | 4. Ratio error, phase error |
| 5. Accuracy limiting factor (ALF) | 5. Degauss |
| 6. Degauss | 6. Calculation of knee point value |
| 7. Ratio error, phase error | 7. Actual secondary load test (burden test) |
| 8. Automatic calculation of excitation knee point value | 8. Resistance test |
| 9. Actual secondary load test (burden test) | |
| 10. Resistance test | |
| 11. Secondary time constant (Ts) | |
| 12. Remanence coefficient (Kr) | |
| 13. Transient dimensioning factor (Ktd) | |
| 14. Peak instantaneous error (Er) | |
| 15. Magnetizing inductance (LU) | |
| 16. Instruments security factor(FS) | |
| 17. Composite error | |
- Similar Products
$5500.00
1 Piece (MOQ)
Manufacturer Supply Temperature Calibrator Dry Block
Beijing Spake Technology Co., Ltd.
$5500.00
1 Piece (MOQ)
Manufacturer of Temperature Probe Calibration
Beijing Spake Technology Co., Ltd.