$30.50
500 Pieces (MOQ)
Mari 2025 Factory Direct Supply Digi-Drive 600W HPS/Mh Grow Light Buble
PUTIAN BELTRI INC.
Swipe or use the arrows to view product images.
Geiger Counter Nuclear Radiation Detector M4011 Hard Tube BetaGM Geiger Counter
| Price | $30.00 |
|---|---|
| Min Order | 10 Pieces |
| Availability | In Stock |
| Shipping From | Jiangsu, China |
| Popularity | 613 people viewed |
Certification:
CE, ISO9001
Light Source:
Fluorescent
Material:
Alloy
Type:
Medical Lighting
IP Rating:
IP67
Trademark:
rongshide
Transport Package:
Custom
Specification:
Per Customer Request
Origin:
China
HS Code:
90189090
Product Description
Geiger-Muller counter, or Geiger counter for short, is a counting instrument that specializes in detecting the intensity of ionizing radiation (alpha particles, beta particles, gamma rays and X-rays). The probe is made from an inflatable tube or chamber, when the voltage applied reaches a certain range, each ionized radiation generating a pair of ions in the tube, the connected electronic device can record an amplified electrical pulse of the same size generated by radiation, thereby measuring the number of rays in a unit time.
The Geiger-Muller counter (Gegenees Counter) can be applied in various scenarios.
In the medical field, the Geiger-Muller counter is employed for detecting and counting radiation from radioactive isotopes or other radioactive markers. In the nuclear energy sector, it contributes to nuclear radiation protection, nuclear facility safety monitoring, nuclear waste management. In that case, it can be applied for radiation detection and monitoring in the environment measuring levels of radioactive substances in soil, air, water sources, etc. By demonstrating real-time radiation presence and intensity visually, it helps enhance radiation safety awareness and operational skills among personnel involved in radiation-related occupations.
Technical Parameters:
Notice:
1. Keep the shell clean
Counting tubes and shells should be kept highly clean. Surface contamination should be decreased as much as possible to avoid insulation resistance reduction.
2. Application of typical working conditions
The characteristic parameters of the counter are all measured under the recommended operating voltage. The same condition is suggested to obtain the given characteristic parameters.
3. Careful installation
Handle it carefully when installation. The lead of the output end of the counter tube should be as short as possible, and the anode and cathode lead-out electrodes should not be subjected to excessive force. Especially notice the tube with glass shell to avoid air leakage and breakage.
The Geiger-Muller counter (Gegenees Counter) can be applied in various scenarios.
In the medical field, the Geiger-Muller counter is employed for detecting and counting radiation from radioactive isotopes or other radioactive markers. In the nuclear energy sector, it contributes to nuclear radiation protection, nuclear facility safety monitoring, nuclear waste management. In that case, it can be applied for radiation detection and monitoring in the environment measuring levels of radioactive substances in soil, air, water sources, etc. By demonstrating real-time radiation presence and intensity visually, it helps enhance radiation safety awareness and operational skills among personnel involved in radiation-related occupations.
Technical Parameters:
| Diameter: | φ 10 ± 0.5mm |
| Total length: | 90 ± 2mm |
| Initial voltage: | < 350V |
| Recommended working voltage: | 380V |
| Minimum plateau length: | 80V |
| Maximum plateau slope: | 10% / 80V |
| Limit operating voltage: | 550V |
| Maximum background count rate: | 25 times / min |
| Lifespan: | > 1 × 10*9 pulse |
Notice:
1. Keep the shell clean
Counting tubes and shells should be kept highly clean. Surface contamination should be decreased as much as possible to avoid insulation resistance reduction.
2. Application of typical working conditions
The characteristic parameters of the counter are all measured under the recommended operating voltage. The same condition is suggested to obtain the given characteristic parameters.
3. Careful installation
Handle it carefully when installation. The lead of the output end of the counter tube should be as short as possible, and the anode and cathode lead-out electrodes should not be subjected to excessive force. Especially notice the tube with glass shell to avoid air leakage and breakage.
- Similar Products
$5.00
100 Pieces (MOQ)
Single End Bright Light Studio Halogen Lamp
Changzhou Dingming Lighting Equipment Co., Ltd.
$107.00
100 Pieces (MOQ)
2025 Grow Lights LED Light Hydroponic Growing System LED Grow Lamp
PUTIAN BELTRI INC.
$58.74
18 Pieces (MOQ)
Dancing Magnetic Fluid Sound Visualizer with Music Rhythm
Yiwu GALAXY Lights Co., Ltd.
$30.00
10 Pieces (MOQ)
Hair/Tatto Removal Laser Machine IPL Lamp
Lumi Photoelectric Technology Co., Ltd.