$1530.00
3 Pieces (MOQ)
1000A Wireless Portable High Voltage Ammeter with Hotstick
Beijing GFUVE Electronics Co., Ltd.
Swipe or use the arrows to view product images.
Handheld three phase programmed standard power source phantom load kwh electric Three phase energy meter calibrator
| Price | $10000.00 |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Hunan, China |
| Popularity | 434 people viewed |
Model NO.:
TD4550
After-sales Service:
Life Time
Warranty:
12 Months Excellent After Service
Application:
Electrical Calibration
Power:
Electricity
Voltage Output:
6 V~456 V
Current Output:
2 mA ~ 110 A
LCD Display:
With LCD Display
Customized:
Non-Customized
Accuracy:
Class 0.02, 0.05, 0.1
Harmonic Output:
2nd~21st
Test software:
optional
Frequency:
45Hz~65Hz
Power output:
0~54kW
Trademark:
TUNKIA
Transport Package:
Package for Exporting
Origin:
China
Product Description
Portable Three-Phase Energy Calibrator
TD4550 is an intelligent and highly integrated test system for calibrating three-phase energy meter and other AC electrical apparatus
. It is built-in 3PH standard source. It can complete intrinsic error test, constant test, standard deviation test, starting current test, test of no-load of electric energy meter.
- Accuracy:class 0.02, 0.05, 0.1
- 3PH ACV output:6 V~456 V
- 3PH ACI output:2 mA ~ 110 A
- Multiple output mode, support three-phase or single adjust
- U-I phase:0°~360°, accuracy 0.01°
- Energy meter test function
- LCD touch screen
- 2nd~21st harmonic output(option)
- Test software(option)
| ☆ Wide Output |
|
| ☆ Convenient Operation |
|
☆ Harmonics Function(Option) | |
| S/N | Function declaration |
| Set amplitude of harmonic. | |
| Set phase of harmonic(fundamental wave). | |
| Choose 2nd~21st harmonics channel output. | |
| Oscilloscope function, user can observe voltage and current waves. | |
| Display frequency spectrum of harmonic by histogram.(fundament wave is 100%) | |
☆ Testing Software(Option) |
|
5.1 Three-Phase Voltage / Current Output
| Voltage Range | Stability ( %/min ) | Accuracy ±(ppm of reading + ppm of range) [1] | Max Burden (mA) | ||||
| Class 0.1 | Class 0.05 | Class 0.02 | Class 0.1 | Class 0.05 | Class 0.02 | ||
| 57.7 V | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 500 |
| 100 V | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 300 |
| 220 V | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 130 |
| 380 V | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 80 |
| Note [1] : (ppm = parts per million) (e.g.,10ppm = 0.001%). | |||||||
| Current Range | Stability ( %/min ) | Accuracy ±(ppm of reading + ppm of range) [1] | Max Burden (V) | ||||
| Class 0.1 | Class 0.05 | Class 0.02 | Class 0.1 | Class 0.05 | Class 0.02 | ||
| 20 mA | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 24 |
| 50 mA | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 24 |
| 100 mA | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 24 |
| 200 mA | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 24 |
| 500 mA | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 24 |
| 1 A | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 24 |
| 2 A | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 6 |
| 5 A | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 6 |
| 10 A | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 2 |
| 20 A | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 2 |
| 50 A | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 0.6 |
| 100 A | 0.02 | 0.01 | 0.005 | 600+400 | 300+200 | 120+80 | 0.6 |
- Three-phase voltage output:6 V~456 V, Three-phase current output:2 mA~120 A
- Degree of distortion:<0.5%
- Degree of symmetry:voltage <0.2%, current <0.5%, phase <0.5°
- Voltage short circuit, current open-circuit and overload protection
5.2 Frequency / Phase / Harmonic
| Frequency | Range:45 Hz~65Hz; Adjustment fineness:0.001 Hz; Accuracy:±0.05 Hz (class 0.1), ±0.02 Hz (class 0.05), ±0.01 Hz(class 0.02) |
| Phase | Range:0.000 0°~359.999 9°; Adjustment fineness:0.001°; Accuracy:±0.05° (class 0.1), ±0.02° (class 0.05), ±0.01°(class 0.02) |
| Harmonic | 2nd~21st harmonic; Amplitude 0~25% adjustable; Phase 0~359.99°adjustable |
5.3 Power / Energy Output
| Type | Current range | Class 0.1 | Class 0.05 | Class 0.02 |
| Output power stability ( % / 2min ) | 50 mA≤I≤120 A | 0.05 | 0.02 | 0.01 |
| 2 mA≤I< 50 mA | 0.05 | 0.03 | 0.02 | |
| Active power /energy |cosΦ| ≥0.5 | 50 mA≤I≤120 A | ±0.1%*reading | ±0.05%*reading | ±0.02%*reading |
| 2 mA≤I< 50 mA | ±0.2%*FS | ±0.1%*FS | ±0.05%*FS | |
| Reactive power /energy |sinΦ| ≥0.5 | 50 mA≤I≤120 A | ±0.2%*FS | ±0.1%*FS | ±0.05%*FS |
| 2 mA≤I< 50 mA | ±0.5%*FS | ±0.2%*FS | ±0.1%*FS | |
| Power factor | 50 mA≤I≤120 A | ±0.1% | ±0.05% | ±0.02% |
| 2 mA≤I< 50 mA | ±0.2% | ±0.1% | ±0.05% | |
| Note [2] :FS= voltage range ×current range | ||||
- Power/energy measure range:combination of voltage range and current range
- Power factor measure range:-1.000 00…0.000 00…1.000 00
- Energy pulse output:High frequency full range is 60 kHz, Low frequency full range is 6 Hz
- Energy pulse input:Frequency ≤ 150 kHz, pulse level::0…3.3 V…24 V
- Energy error display:auto,resolution as 0.0001%
| Power Supply | AC ( 220 ± 22 ) V,( 50 ± 2 ) Hz |
| Temperature Performance | Working temperature:0°C~45°C; Storage temperature:-20°C~70°C |
| Humidity Performance | Working humidity:< 80% @ 30°C,< 70% @ 40°C,< 40% @ 50°C Storage humidity:(20%~80%) R·H,non-condensing |
| Interface | RS232 |