Swipe or use the arrows to view product images.
High Quality Electric Water Pump Centrifugal Jockey Pump
| Price | $500.00 |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Shanghai, China |
| Popularity | 504 people viewed |
Model NO.:
LQDL/LQDLF
Max.Head:
>150m
Max.Capacity:
>400 L/min
Driving Type:
Motor
Impeller Number:
Multistage Pump
Working Pressure:
High Pressure Pump
Influent Type of Impeller:
Clear Water
Position of Pump Shaft:
Vertical Pump
Impeller:
Closed
Usage:
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump
Type:
Lqdl/Lqdlf
Color:
Black
Material:
Cast Iron
Motor:
100% Cooper Wire
Pressure:
High Pressure
Theory:
Centrifugal
Trademark:
LYSON or OEM
Transport Package:
Wooden Box
Specification:
ISO9001/CE
Origin:
Shanghai, China
HS Code:
8413709990
Product Description
Products Name: High quality Long Duration Time Electric Water Pump Centrifugal Jockey Pump with Long Service Life
Conditions of use: Suitable for conveying the temperature under 120 celsius water and similar to that of liquid water, pump system working pressure of up to 30 bar.
The scope of performance parameter: This series a total of 26 species, 348 kinds of specifications and its
performance parameters range:
1 flow Q= 1~150m3/h
2. Lift H= 6 ~ 305 m
3. Speed n=1480/2980 r/min
4. Power P= 0.37~ 75kW
PS: LQDLD is Mute Series.
| fault phenomenon | failure cause | elimination methods |
| The manual is normal Automatic transmission failure | 1.No power supply or one or two phase power supply is needed | Check all phases of power supply and restore power supply |
| Water level is too low | Put water in the sink | |
| The motor burned | Repair or replace the motor | |
| 1.Line is loose | Check wiring and tighten connectors | |
| 2.Frequency converter malfunction | Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting. | |
| 3The frequency converter is damaged | Repair or replace | |
| 4.Pressure switch damage | Repair or replace | |
| 5The pressure transmitter is damaged | Repair or replace | |
| 6.Switch failure | Repair or replace | |
| Pump non - suction pressure gauge pointer to beat violently | Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument | Check pipeline and bottom valve, refill water diversion. Tighten air leakage |
The pump consumes too much power | Too much flow, impeller wear | Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow |