Swipe or use the arrows to view product images.
IEC 60598-1 Safety Test Chain for Lighting Short Circuit Protection Test
| Price | $198.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Guangdong, China |
| Popularity | 347 people viewed |
Model NO.:
test chain
After-sales Service:
Good
Warranty:
One Year
Function:
Protection
Application:
Industrial
Certification:
CE, RoHS
Type:
Safety Test Equipment
Installation Mode:
Handheld
Delivery Time:
3-7days
Standard:
IEC60950
Product Name:
Test Chain
Size:
2.5+/-20%
Trademark:
bnd
Transport Package:
Safety Wooden Box
Specification:
iec60950
Origin:
China
Product Description
IEC 60598-1 safety test chain for lighting short circuit protection test
Specification:
1, Standards: IEC60598-1 EN60598-14.26.3
2, Test Chain is composed of copper and zinc alloy (Cu 63% Zn37%)without any surface treatment and coating ,
200g/m load tensile resistance at 2.5±20%Ω according to IEC60598-1 standards.
Application:
1)Measuring chain resistance, to ensure that the range of 2.5 ± 20% Ω .
2)Measuring distance space of the SELV two parts, denoted as X,unit (/ cm).
3)Test chain ends hanging standard weight =15*X*g or 250g counterweight.
4)Install the thermocouple wire on proper position of the tested sample, and connecting with temperature inspecting instrument.
5)Sample access 0.9~1.1 times the rated voltage of power supply.
6)Placement test chain, short-circuit test.
It mainly used for lighting without insulation , accessible and opposite SELV part accidental short circuit protection test.
Appliance:
The tip of the glow-wire is then brought smoothly into contact with the test specimen for a duration of 30 s ± 1 s. An approximate rate of approach and withdrawal of 10 mm/s to 25 mm/s has been found to be satisfactory. However, the rate of approach shall be reduced to near zero upon contact to avoid impact forces exceeding 1,05 N. In those cases where the material melts away from the glow-wire, the glow-wire shall not be kept in contact with the test specimen. Following the application time, the glow-wire and the test specimen are slowly separated, avoiding any further heating of the test specimen and any movement of air which might affect the result of the test. The penetration of the tip of the glow-wire into and through the test specimen shall be limited to 7 mm ± 0,5 mm.
When forming the glow-wire , care shall be taken to avoid fine cracking at the tip.
NOTE:
Annealing is a suitable process for prevention of fine cracking at the tip.
Specification:
1, Standards: IEC60598-1 EN60598-14.26.3
2, Test Chain is composed of copper and zinc alloy (Cu 63% Zn37%)without any surface treatment and coating ,
200g/m load tensile resistance at 2.5±20%Ω according to IEC60598-1 standards.
Application:
1)Measuring chain resistance, to ensure that the range of 2.5 ± 20% Ω .
2)Measuring distance space of the SELV two parts, denoted as X,unit (/ cm).
3)Test chain ends hanging standard weight =15*X*g or 250g counterweight.
4)Install the thermocouple wire on proper position of the tested sample, and connecting with temperature inspecting instrument.
5)Sample access 0.9~1.1 times the rated voltage of power supply.
6)Placement test chain, short-circuit test.
It mainly used for lighting without insulation , accessible and opposite SELV part accidental short circuit protection test.
Appliance:
The tip of the glow-wire is then brought smoothly into contact with the test specimen for a duration of 30 s ± 1 s. An approximate rate of approach and withdrawal of 10 mm/s to 25 mm/s has been found to be satisfactory. However, the rate of approach shall be reduced to near zero upon contact to avoid impact forces exceeding 1,05 N. In those cases where the material melts away from the glow-wire, the glow-wire shall not be kept in contact with the test specimen. Following the application time, the glow-wire and the test specimen are slowly separated, avoiding any further heating of the test specimen and any movement of air which might affect the result of the test. The penetration of the tip of the glow-wire into and through the test specimen shall be limited to 7 mm ± 0,5 mm.
When forming the glow-wire , care shall be taken to avoid fine cracking at the tip.
NOTE:
Annealing is a suitable process for prevention of fine cracking at the tip.
Company Profile :
Certifications :
Customer Reviews :
- Similar Products
$265.00
1 Piece (MOQ)
Digital Gauss Meter, Tesla Meter Mt-200da
Guangzhou Amittari Instruments Co., Ltd.
$350.00
1 Piece (MOQ)
Set50 UL1439 Sharp Edge Tester for Children Toys
Shenzhen Bonad Instrument Co., Ltd.
$399.00
1 Piece (MOQ)
Baby Safety Sharp Edge Tester with 21 Sharp Tape Kits
Shenzhen Bonad Instrument Co., Ltd.
$200.00
1 Piece (MOQ)
IEC61032 IEC60529 IP2X Accessibility Probe B Test Finger
Shenzhen Bonad Instrument Co., Ltd.