Lsk System Electric Control Cabinet Booster Pump Control Panel
| Price | $199.00 |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Shanghai, China |
| Popularity | 462 people viewed |
Model NO.:
LSK
After-sales Service:
1 Year
Warranty:
1 Year
Max.Head:
>150m
Max.Capacity:
>400 L/min
Driving Type:
Motor
Impeller Number:
Multistage Pump
Working Pressure:
High Pressure Pump
Influent Type of Impeller:
Clear Water
Position of Pump Shaft:
Vertical Pump
Pump Casing Combined:
Horizontal Split Pumps
Mounting Height:
Since Irrigation Centrifugal Pumps
Impeller:
Closed
Usage:
Pump, Pumps, Condensate Pump, Slurry Pump, Circulating Pump
Type:
Lsk
Color:
Silver
Material:
Cast Iron
Motor:
100% Cooper Wire
Pressure:
High Pressure
Theory:
Centrifugal
Trademark:
LYSON or OEM
Transport Package:
Standard Export Packing or According to Customers'
Specification:
ISO9001/CE
Origin:
Shanghai, China
HS Code:
8413709990
Product Description
Products Name: LSK System Electric Control Cabinet
Conditions of use: Suitable for conveying the temperature under 60 celsius water and similar to that of liquid water, pump system working pressure of up to 11 bar.
The scope of performance parameter: This series a total of 6 species, 50kinds of specifications and its
performance parameters range:
1 flow Q= 18~108 m3/h
2. Lift H= 30 ~ 160 m
3. Speed n=1450/2900 r/mi8
4. Power P=1.1~ 274kW
| fault phenomenon | failure cause | elimination methods |
| The manual is normal Automatic transmission failure | 1.No power supply or one or two phase power supply is needed | Check all phases of power supply and restore power supply |
| Water level is too low | Put water in the sink | |
| The motor burned | Repair or replace the motor | |
| 1.Line is loose | Check wiring and tighten connectors | |
| 2.Frequency converter malfunction | Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting. | |
| 3The frequency converter is damaged | Repair or replace | |
| 4.Pressure switch damage | Repair or replace | |
| 5The pressure transmitter is damaged | Repair or replace | |
| 6.Switch failure | Repair or replace | |
| Pump non - suction pressure gauge pointer to beat violently | Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument | Check pipeline and bottom valve, refill water diversion. Tighten air leakage |
The pump consumes too much power | Too much flow, impeller wear | Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow |
♦ ESTABLISHED IN THE SIXTIES
♦ THROUGH THE ISO9001:2015 DOMESTIC,
INTERNATIONAL QUALITY SYSTEM CERTIFICATION
♦ SILVER MEDAL WAS AWARDED AT THE NATIONAL CONFERENCE ON THE
APPLICATION OF SPARK CUP TECHNOLOGY
♦ WIN THE NATIONAL AWARD FOR EXCELLENCE IN CIVILIZATION COMPETITION
♦ GET THE LC OF THE CHINESE GOVERNMENT
- Similar Products