Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Mobile Trailer Mounted Diesel Generator 20kVA 30kVA 50kVA 80kVA 100kVA Electric Trolley Generators

Price $3000.00
Min Order 1 SET
Availability In Stock
Shipping From Fujian, China
Popularity 259 people viewed
Model NO.:
MC
After-sales Service:
Responsible
Warranty:
12 Months or 1200 Operation Hours
Type:
Self-Starting Diesel Generator
Installation Method:
Fixed
Stroke:
Four Stroke
Cooling Method:
Water Cooling
Output Type:
AC Three Phase
Speed:
Low Speed
Conditions of Use:
Land Use
Usage:
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit:
Automation Type
Excitation Mode:
Static Exciter
Engine Brand:
Cummins/Perkins/Doosan/Deutz/Yanmar/Mitsubishi
Alternator Brand:
Stamford/Marathon/Leroy Somer/Mecca, Optional
Control Panel:
Deepsea/Comap/Datakom/Delixi/Smartgen, etc.
Phase:
Single Phase/Three Phase
Canopy Type:
Silent Sound Proof/Weather Proof/Anti-Rusted Proof
Frequency(Hz):
50Hz/60Hz, 1500rpm 1800rpm
Voltage Output:
230/400V, 220-480V
Application:
Telecom/Commercial/Power Plant/Construction
Cylinder:
Single/Two/Three Cylinder
Diesel Engine Generator:
Doosan Diesel Generator
Governing Type:
Mech/Elec/ECU/Ecm/Adec/Hpcr
ATS:
Optional
Certificate Available:
CE, ISO, OEM Authorization etc.
Maximun Permissible High Altitude:
2500m
Power Generation:
Generating Sets
Trademark:
Mecca
Transport Package:
Both Standard Marine Packing or Compact Packing.
Specification:
As below Spec. with details
Origin:
China
HS Code:
85021100
Product Description
Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

MECCA POWER Trailer Type Diesel Generator Sets

(1) 2~8 wheels,optional;
(2) single or double bearing,
(3) front supporting regulating wheel,
(4) direction leading system,
(5) supporting leg,
(6) braking system,
(7) traffic light in the back,
(8) 
reflective traffic stickers.
 


Payment Terms:
By telegraphic transfer: 30% deposit on signing of sales contract; and balance 70% before dispatch. 
                              
Delivery:
Approximately 2-4 weeks upon order confirmation.

Service Guarantee:
Before Service: According to the clients' requirement and actual situation, we will furnish the technology consultation and kinds of information. 

After Service: Guarantee for one year or 1200 running hours (accord to whichever reach first) from installed date.
During the guarantee period, we will provide the free easy-damaged spare-parts for problems caused by our quality of production or raw material, except the damageable spare parts of diesel engine caused by customer's incorrect man-made operation. After checking, our company provides cost spare-parts maintenance for gensets . 


Beside genset one-stop purchasing service to world-wide customers,CKD and SKD packing service are also available according to unique request.

CKD:Complete Knock Down Generator
Generator completely knocked down into parts without assembling. 
All items from following are seperately packed without connection.
 
SKD:Semi Knock Down Generator
Partially assembled generator. 
Part of the following items you choose will be assembled.
 
Advantage:
Prompt delivery
Reduced tax to win more competition
Lower transportation fees to save cost
Localized production to win more tenders. 
Increased production to offer more job opportunity for the government

Item
 

Service
 

Option
 

Delivery Time
 
1EngineDoosan, Mtu, Mitsubishi, SME,  Volvo, 
Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.
Marine and industry use 
Diesel, gas
2-45days
2AlternatorStamford, Leroysomer,  Meccalte,  Marathon  and 
customer requested alternators
Medium and high voltage, 
Marine and industry use 
High IP Grade
CT Drop kits, PMG, AVR
2-15 days
3RadiatorFast, Beworld brand
Original Radiator come with engine
Local made radiator with authorization by engine supplier
2-7days
4CanopiesPowder coated and form mounted canopy,completely break down with hings,
locks, raincap,bolts,screws, etc.
Exhaust pipe and flanges 
Standard silent type canopy package 
Denyo type canopy package 
Rental type canopy package 
Telecom type canopy package 
Super silent type canopy package 
Containerized type canopy package 
Customerized type canopy package
10days
5Base frameStandard base or simple iron base
Anti-Vibration mountings
With/without tank, base tank volume no limited
Fuel gauges and high pressure fuel pipes
3days
6Control systemController: ComAp, DeepSea, Datacom, SmartGen etc.
Breaker:Delixi,ABB, Chint, etc.
Battery switch, battery charger, emergency stop botton, 
indicator, meters, CT and all wiring and harness.
Batteries and cables
Speed & lub oil & water temp sensors,
A package of standard parts for assembly
3days
7Exhaust SystemIndustrial and residential silencer
Flexible connects and elbow
3days
8
Others
 
Special demands 

-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting          

This section lists the generating set for some common fault, the reasons for the failure and determines the           
method of fault. General operators can determine their own fault and note, maintenance it according to the           
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.           
Please remember the following suggestions before repairing:           
- Make sure that study the failure carefully before any operation.           
- Repair with the easiest way and most commonly used method.           
- Find the exact causes of failure and completely solve the fault.     
   

1. Generator Sets          
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.           
(Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.
  • Similar Products