$130.00
10 Pieces (MOQ)
high voltage DC power supply 60W 70W 80W 90W CF04
SUQIAN BOER HIGH VOLTAGE POWER SUPPLIES CO., LTD.
Swipe or use the arrows to view product images.
Nvvv Switching Power Supply AC-DC Power Supply 5V/12V/24V/36V/48V 50W/100W/150W/200W/350W Switching Power Supply
| Price | $15.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 256 people viewed |
Model NO.:
MS Series
Output Type:
Single
Warranty:
3 Years
Output Power:
15W/25W/35W/50W/75W/100W/150W/200W/350W
Input Voltage:
110-220V
Connection Mode:
Series Switching Power Supply
Starting Mode:
Separate-excited Switching Power Supply
Voltage Regulating Mode:
Width Modulation Type
Power Supplying System:
Terminal Power Distribution Equipment
Energy Transmission:
One-way Transmission
Modulation System:
PWM
Certification:
CE, RoHS, ISO, CCC
Brand:
Nvvv
Protections:
Short Circuit Overload Overvolt Overtemp
Output Current:
1A-20A
Product Name:
Switch Power Supply
MOQ:
1PCS
Efficiency:
86%~95%
Quality:
100%Factory
Output Voltage:
5V 12V 24V 36V 48V
Application:
LED Display/Household Appliances/Industrial Device
Output Frequency:
47-63Hz
Trademark:
NVVV
Transport Package:
Safety Packaging
Specification:
199*110*50
Origin:
China
Product Description
| MS-15 15W Switching Power Supply | |||
| Project | Technical index | ||
| Output | DC voltage | 12V | 24V |
| Rated current | 1.25A | 0.62A | |
| Rated power | 15.6W | 16.8W | |
| Ripple and noise | <120mV | <150mV | |
| Voltage accuracy | ±1% | ||
| Output voltage regulation range | ±10% | ||
| Load adjustment rate | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | ||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | |
| Efficiency (typical) | >82% | >84% | |
| Working current | <0.3A 110VAC <0.15A 220VAC | ||
| Impulse current | 110VAC 18A, 220VAC 36A | ||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |
| Short circuit protection | +VODrop to undervoltage point to close output | ||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |
| Leakage current | Input output 1.5KVACtime <5mA | ||
| Leakage current | Input output 220VACtime <1mA | ||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | ||
| Other | Size | 87*37*60mm (L*W*H) | |
| Net Weight /Gross Weight | 0.15/0.18 KG | ||
| MS-25 25W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 5V | 12V | 24V |
| Rated current | 4A | 2.1A | 1A | |
| Rated power | 20W | 25.2W | 24W | |
| Ripple and noise | <50mV | <120mV | <150mV | |
| Voltage accuracy | ±2% | ±1% | ||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >78% | >82% | >84% | |
| Working current | <0.5A 110VAC <0.25A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVACtime <5mA | |||
| Leakage current | Input output 220VACtime <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 87*37*60mm (L*W*H) | ||
| Net Weight /Gross Weight | 0.15/0.18 KG | |||
| MS-35 35W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 5V | 12V | 24V |
| Rated current | 6A | 2.9A | 1.5A | |
| Rated power | 30W | 34.8W | 36W | |
| Ripple and noise | <50mV | <120mV | <150mV | |
| Voltage accuracy | ±2% | ±1% | ||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >78% | >82% | >84% | |
| Working current | <0.8A 110VAC <0.35A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVACtime <5mA | |||
| Leakage current | Input output 220VACtime <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 87*37*60mm (L*W*H) | ||
| Net Weight /Gross Weight | 0.15/0.18 KG | |||
| MS-50 50W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 5V | 12V | 24V |
| Rated current | 8A | 4.2A | 2.1A | |
| Rated power | 40W | 50.4W | 50.4W | |
| Ripple and noise | <50mV | <120mV | <150mV | |
| Voltage accuracy | ±2% | ±1% | ||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >78% | >82% | >84% | |
| Working current | <0.8A 110VAC <0.35A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 111*36*78mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3/0.35KG | |||
| MS-60 60W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 5A | 2.5A | 1.25A | |
| Rated power | 60W | 60W | 60W | |
| Ripple and noise | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±1% | |||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >82% | >84% | >84% | |
| Working current | <0.8A 110VAC <0.35A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 111*36*78mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3/0.35KG | |||
| MS-75 75W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 6.25A | 3.12A | 1.56A | |
| Rated power | 75W | 75W | 75W | |
| Ripple and noise | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±1% | |||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Incput | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >84% | >84% | >84% | |
| Working current | <1A 110VAC <0.65A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | ≥ 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | vInput output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 111*36*78mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3/0.35KG | |||
| MS-100 100W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 8.3A | 4.1A | 2.1A | |
| Rated power | 99.6W | 100.8W | 100.8W | |
| Ripple and noise | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >82% | >84% | >84% | |
| Working current | <1.8A 110VAC <1.1A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 159*38*98mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3KG | |||
| MS-120 120W Switching Power Supply | ||||
| Project | Technical index | |||
| Output | DC voltage | 12V | 24V | 48V |
| Rated current | 10A | 5A | 2.5A | |
| Rated power | 120W | 120W | 120W | |
| Ripple and noise | <120mV | <150mV | <150mV | |
| Voltage accuracy | ±1% | |||
| Output voltage regulation range | ±10% | |||
| Load adjustment rate | <±1.5% | <±0.5% | <±0.5% | |
| Linear adjustment rate | <±0.5% | |||
| Input | Voltage range | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
| Efficiency (typical) | >82% | >84% | >84% | |
| Working current | <2A 110VAC <1.3A 220VAC | |||
| Impulse current | 110VAC 18A, 220VAC 36A | |||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | |||
| Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||
| Short circuit protection | +VODrop to undervoltage point to close output | |||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | ||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | |||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||
| Leakage current | Input output 1.5KVAC <5mA | |||
| Leakage current | Input output 220VAC <1mA | |||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | |||
| Other | Size | 159*38*98mm(L*W*H) | ||
| Net Weight /Gross Weight | 0.3KG | |||
| MS-250 250W Switching Power Supply | |||||
| Project | Technical index | ||||
| Output | DC voltage | 5V | 12V | 24V | 48V |
| Rated current | 40A | 20.8A | 10.4A | 5.2A | |
| Rated power | 200W | 249.6W | 249.6W | 249.6W | |
| Ripple and noise | <50mV | <120mV | <150mV | <240mV | |
| Voltage accuracy | ±2% | ±1% | |||
| Output voltage regulation range | ±10% | ||||
| Load adjustment rate | <±0.5% | <±0.5% | <±0.5% | ||
| Linear adjustment rate | <±0.5% | ||||
| Input | Voltage range | 185-264VAC 47Hz~63Hz (254VDC~370VDC) | |||
| Efficiency (typical) | >82% | >84% | >84% | ||
| Working current | <2.5A 220VAC | ||||
| Impulse current | 220VAC 36A | ||||
| Start, rise, hold time | 200ms,50ms,20ms :220VAC | ||||
| Protect | overload protection | 105% - 150% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
| Short circuit protection | +VODrop to undervoltage point to close output | ||||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
| Leakage current | Input output 1.5KVAC <5mA | ||||
| Leakage current | Input output 220VAC <1mA | ||||
| Isolation resistance | Input output,Input - Housing, Output - Housing:500VDC/100MΩ | ||||
| Other | Size | 199*50*110mm(L*W*H) | |||
| Net Weight /Gross Weight | 0.72/0.78KG | ||||
| MS-350 350W Switching Power Supply | |||||
| Project | Technical index | ||||
| Output | DC voltage | 12V | 24V | 36V | 48V |
| Rated current | 29A | 14.5A | 9.7A | 7.3A | |
| Rated power | 350W | 350W | 350W | 350W | |
| Ripple and noise | <120mV | <240mV | <240mV | <240mV | |
| Voltage accuracy | ±1.0% | ||||
| Output voltage regulation range | ±10% | ||||
| Load adjustment rate | ±0.5% | ||||
| Linear adjustment rate | ±0.5% | ||||
| Input | Voltage range | 90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC | |||
| Efficiency (typical) | >83% | >85% | >86% | >86% | |
| Working current | 110VAC 25A, 220VAC: 50A | ||||
| Impulse current | <5.5 A 115VAC <2.9A 230VAC | ||||
| Start, rise, hold time | 200ms,50ms,20ms :230VAC | ||||
| Protect | overload protection | 105% - 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
| Short circuit protection | 115%-145% | ||||
| Undervoltage protection | 10%-45%VOUT | ||||
| Temperature protection | Rth3: ≥ 55 ºC fan start, ≥ 50 ºC fan close, ≥ 85 ºC close output (5v-15v) | ||||
| Environmental Science | Working temperature and humidity | -10ºC~+50ºC;20%~90RH | |||
| Working temperature and humidity | -20ºC~+85ºC;10%~95RH | ||||
| Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 2.5kvac output shell: 0.5kvac for 1 minute | |||
| Leakage current | Input output 1.5KVAC <6mA | ||||
| Leakage current | Input output 220VAC <1.5mA | ||||
| Isolation resistance | Input output,Input - Housing, Output - Housing :500VDC/100MΩ | ||||
| Other | Size | 199*38*98mm(L*W*H) | |||
| Net Weight /Gross Weight | 0.62/0.65 KG | ||||
Q1:How many Voltage you can supply? A: 12v,24v,48v,50,60,110v(Depend on items).
Q2Can I have a sample order? A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.
Q3Do you have any MOQ limited for the order? A: Low MOQ, 1pc for sample checking is available. At the same time, we have overseas warehouses so that you can get the products faster.
Q4How do you ship the goods and how long does it take to arrive? A: We usually ship by DHL, UPS, FedEx or EMS. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q5Do you offer guarantee for the products? A: Yes, we offer warranty to our products.
Q6: How to deal with the faulty? A: Firstly, our products are produced in strict quality control system and the defective rate will be less. Secondly, during the guarantee period,we will send new product with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.
- Similar Products
$2000.00
1 Piece (MOQ)
Magnetron Sputter Power Source Price 6kw 10kw
Xi'an Feng Yu Industry Co., Ltd.
$32.00
100 Pieces (MOQ)
800W DC48V 16A Switching Power Supply with Ce RoHS
Shenzhen Mingwei Electric Power Co., Ltd.