UL Standard Medium Voltage Industrial XLPE Epr Urd Mv Mv-90 Mv-105 Power Cable Aluminum Copper Conductor Underground Electric Electrical Wire Construction

Price $30.00
Min Order 10000 Feet
Availability In Stock
Shipping From Hebei, China
Popularity 454 people viewed
Model NO.:
power cable MV90, MV105
Application:
Construction, Underground, Industrial, Installed in Raceways, Duct
Voltage:
Low and Medium Voltage Cable
Current:
DC & AC
Insulation Material:
XLPE
Sheath Material:
LLDPE, MDPE, PVC
Material Shape:
Round Wire
Wire Core Material:
Aluminum, Bare Copper Wire
Certification:
ISO, CCC, RoHS, CSA68.5
Model:
Medium Voltage Power Cable Mv90, Mv105
Brand:
Rneda
Products Name:
Medium Voltage Power Cable, Mv90, Mv105
UL Listed Type:
Mv90, Mv105
Standard:
UL1072, Icea S-93-639
Rated Voltage:
5kv, 8kv, 15kv, 25kv, 35kv
Insulation:
Tr-XLPE, Epr
Sheath:
LLDPE, PVC
Working Temperture:
Max 90 Degree or 105degre
Sheath with Strip:
Red Strip
Insulation Level:
100% or 133%
Sample Available:
Yes
Trademark:
RENDA
Transport Package:
Reel as Your Requirements
Specification:
8AWG TO 1000MCM
Origin:
China
HS Code:
8544492100
Product Description
Medium Voltage Industrial 15kv 35kv Xlp Epr Urd Mv-90 & Mv-105 Power Cable UL Type 1072 Icea 94 649 Electric Aluminum Conductor Underground Distribution Wire
 
Applications
For use in power circuits up to 35 kV when installed in the open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants, refineries, steel mills, industrial plants, utility substations and generating stations

Standards & References
Primary UD TRXLP Cable meets or exceeds the following ASTM specifications:
• B3 Soft Annealed Copper Wire
• B8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft
• B230 Aluminum, 1350-H19 Wire for Electrical Purposes
• B231 Aluminum 1350 Conductors, Concentric-Lay-Stranded
• B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes

UD TRXLP Cable is manufactured to the latest edition of the following specifications, and
in case of specification conflicts, in the order listed:
• ANSI/ICEA S-94-649
• AEIC CS-8
• UL1072, When Specified

Construction
Conductors: Bare, annealed copper per ASTM B-3, aluminum compact conductor.
Internal semiconductor: Screen over the conductor, made of thermosetting semiconductor material.
Insulation: Cross-linked polyethylene (XLPE)/Ethylene propylene rubber (EPR), in dry atmosphere catenary tube, through a triple layer extrusion process.
External semiconductor: Screen over the insulation, made of thermosetting and strippable semiconductor material.
Metallic screen: Screen of copper wires.
External sheath: PVC, red or black color.LLDPE

Temperature Range: -40°C to +90/105°C
Voltage Rating: 5KV 8KV 15KV 25KV 35KV 
Phase Conductor Neutral Thickness Per Cond. (mils) Diameter (mils) Weight 1000 feet (lbs.)  Allowable Ampacities+ 
Size (AWG or kcmil)  Strand-ing No. of Wires  Size (AWG) Nominal Insul. Insul. Shield min. Point Approx. Jkt. Bare Phase Cond. Over Insul. Over Insul. Shield Comp. Cable Comp. Cable Direct Burial In Ducts
ALUMINUM CONDUCTOR - 100% INSULATION LEVEL 
2Solid 10141753050258653733961453168* 119* 
2710141753050283678758986470168* 119* 
1Solid 13141753050289685765993520193* 137* 
119131417530503227187981026539193*  137* 
1/0 Solid 161417530503257208001028591218*  155* 
1/0 19161417530503527488281056609218*  155* 
2/0 19201417530503957908701098703248*  177* 
3/0 19251417530504438389181146817284*  201* 
4/0 19201217530504988939731234993324*  230* 
2503716101753050558963104313461213360* 257* 
35037181417540506611068116813961055389** 319** 
50037251417540507891193129315211349468** 384** 
75061241217540809681383148317981946569** 468** 
1000612010175408011171530163019882473642** 542** 
1250912510220558012501765189522533142688** 604** 
1500913010220558013701885201523733616726** 637** 
 


 
 