Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

UL2231-2 Ccid20 RCD AC 20mA DC 5mA Fault Leakage Current Detection Rcm Sensor

Price $14.76
Min Order 1 Piece
Availability In Stock
Shipping From Shanghai, China
Popularity 346 people viewed
Model NO.:
MD20STA-C
Type:
Electromagnetic
Output Signal Type:
Digital Output
Production Process:
Integration
Material:
Plastic
Application:
Residual Current Protection
Certification:
RoHS
Customized:
Customized
Product Name:
American UL RCD Leakage Current Sensor
Alarm Current:
DC 40X1.414mA, AC 15~20mA
Installation:
Cable/Horizontal Installation
Alarm Output:
Open Collector
Application Scenarios:
EV Charger, Solar Inverter
Theory:
Current Sensor
Plastic Casing:
SIP Encapsulation
Trademark:
IVY
Transport Package:
Cartons
Specification:
TBA
Origin:
Zhejiang, China
HS Code:
8536411000
Product Description
Voltage12V±20% 
Leakage Protection TypeCCID20
Alarm Current DC 40x1.414=56.56mA/AC 15~20mA
Alarm OutputOpen Collector Output
Operation Temperature Range-25~+80ºC
InstallationCable/Horizontal Type
AppearancePlastic casing V0

Caution of Leakage Sensor:

MD36DA-C is a DC leakage current sensor with the characteristics of high sensitivity, accurate measurement, small size, and integration. When a DC leakage current of 3~6mA is detected, an alarm signal will be output, and it has a self-test function.

MD series residual current sensor (RCD/RCM) is an ideal protection device, for the detection and protection of different leakage currents/residual currents/fault currents. The RCD could quickly output alarm signal when people get an electric shock or leakage current exceeds stipulated value, protecting personal and electrical equipment safety.

AS a Type B RCD, MD series leakage sensor have numerous applications and are suitable for many industries including electric vehicle charging, photovoltaic systems (solar panels), industrial device, medical device, new energy, DC screen, fire distribution cabinet, IOT field and any installation where there is a risk of DC current flowing. It is the technology that brings us closest to total protection for all known residual fault currents.