$100.00
100 Meters (MOQ)
3 Core 95mm ² Aluminum Conductor XLPE Insulated Medium Voltage Power Cable
Xingshen Cable Group Co., Ltd
Swipe or use the arrows to view product images.
Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
| Price | $30.00 |
|---|---|
| Min Order | 100 Meters |
| Availability | In Stock |
| Shipping From | Shandong, China |
| Popularity | 435 people viewed |
Model NO.:
low voltage cable
Application:
Construction, Underground, Industrial, Power Station, Telecommunication
Voltage:
Low and Medium Voltage Cable
Current:
DC & AC
Insulation Material:
PVC
Sheath Material:
PVC
Material Shape:
Round Wire
Wire Core Material:
Bare Copper Wire
Certification:
ISO, CCC, CE, RoHS, VDE
Model:
VV, Yjv...
Brand:
Chang Qing Teng
Product Name:
Low Voltage Cable/ PVC Cable/ XLPE Cable/ Armoured
Number of Cores:
Single/2/3/4/5/6/7/8/10/16 Core...
Cross Section Area/Measure:
3.5/4/6/10/16/25/35/50/70/95/120/150/185/240/300/4
Standard:
IEC 60502-1, BS 7870-6, BS 6622, BS 7835, GB 5023-
Conductor:
Stranded/Solid/Flexible Copper/Aluminum Conductor
Insulation:
XLPE/PVC/PE/PUR
Aplication:
Electric, House Wire, Building Wire...
Shield:
Copper Wire Screen(Cws), Aluminium Wire Screen(Aws
Armoured:
Steel Tape Armoured (Sta) or Steel Wire Armoured (
Trademark:
Luxing
Transport Package:
Non-Fumigation Wooden Drum, Iron-Wooden Drum.
Specification:
350x160x270,800x350x550,1000x500x600,1200x500x900.
Origin:
Shandong
HS Code:
8544492100
Product Description
YJV YJV22 YJV32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage
1.Applications
-These cables are used for electricity supply in low voltage installation system.
-They are suitable for installation in indoors and outdoors,in cable ducts, underground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.
2.Construction
-Conductors
The conductors shall be either of Class 1 or Class 2 of plain accordance with IEC 60228.
-Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
-Assembly / Inner Covering
The inner coverings may be extruded or lapped.
-Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
-Outer Sheath
Outer sheath shall be of extruded PVC as per IEC 60502-1, Polyethylene, Halogen free compound.
Polychloroprene, chlorosulfonated polyethylene or similar polymers.
-Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Parameters
| Single core(unarmoured) | ||||||
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
| mm^2 | mm | mm | mm | mm | ||
| 1x4 | 2.3 | 1 | 1.4 | 7.1 | ||
| 1x6 | 2.8 | 1 | 1.4 | 7.6 | ||
| 1x10 | 3.6 | 1 | 1.4 | 8.4 | ||
| 1x16 | 4.5 | 1 | 1.4 | 9.3 | ||
| 1x25 | 5.6 | 1.2 | 1.4 | 10.8 | ||
| 1x35 | 6.7 | 1.2 | 1.4 | 11.9 | ||
| 1x50 | 8 | 1.4 | 1.4 | 13.6 | ||
| 1x70 | 9.4 | 1.4 | 1.4 | 15.1 | ||
| 1x95 | 11 | 1.6 | 1.5 | 17.2 | ||
| 1x120 | 12.4 | 1.6 | 1.5 | 18.7 | ||
| 1x150 | 13.8 | 1.8 | 1.6 | 20.6 | ||
| 1x185 | 15.3 | 2 | 1.7 | 22.7 | ||
| 1x240 | 17.5 | 2.2 | 1.8 | 25.4 | ||
| 1x300 | 19.5 | 2.4 | 1.9 | 28.0 | ||
| 1x400 | 22.6 | 2.6 | 2.0 | 31.7 | ||
| 1x500 | 25.2 | 2.8 | 2.1 | 35.0 | ||
| 1x630 | 28.3 | 2.8 | 2.2 | 38.3 | ||
| Two cores(unarmoured) | ||||||
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
| mm^2 | mm | mm | mm | mm | ||
| 2x1.5 | 1.4 | 0.8 | 1.8 | 9.6 | ||
| 2x2.5 | 1.8 | 0.8 | 1.8 | 10.4 | ||
| 2x4 | 2.3 | 1 | 1.8 | 12.2 | ||
| 2x6 | 2.8 | 1 | 1.8 | 13.2 | ||
| 2x10 | 3.6 | 1 | 1.8 | 14.8 | ||
| 2x16 | 4.5 | 1 | 1.8 | 16.6 | ||
| 2x25 | 5.6 | 1.2 | 1.8 | 19.6 | ||
| 2x35 | 6.7 | 1.2 | 1.8 | 21.8 | ||
| 2x50 | 8 | 1.4 | 1.8 | 25.2 | ||
| 2x70 | 9.4 | 1.4 | 1.9 | 28.1 | ||
| 2x95 | 11 | 1.6 | 2.0 | 32.4 | ||
| 2x120 | 12.4 | 1.6 | 2.1 | 35.4 | ||
| 2x150 | 13.8 | 1.8 | 2.2 | 39.2 | ||
| 2x185 | 15.3 | 2 | 2.4 | 43.3 | ||
| 2x240 | 17.5 | 2.2 | 2.5 | 48.9 | ||
| 2x300 | 19.5 | 2.4 | 2.7 | 54.0 | ||
| 2x400 | 22.6 | 2.6 | 2.9 | 61.5 | ||
| Three cores(unarmoured) | ||||||
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
| mm^2 | mm | mm | mm | mm | ||
| 3x1.5 | 1.4 | 0.8 | 1.8 | 10.1 | ||
| 3x2.5 | 1.8 | 0.8 | 1.8 | 10.9 | ||
| 3x4 | 2.3 | 1 | 1.8 | 12.9 | ||
| 3x6 | 2.8 | 1 | 1.8 | 13.9 | ||
| 3x10 | 3.6 | 1 | 1.8 | 15.7 | ||
| 3x16 | 4.5 | 1 | 1.8 | 17.6 | ||
| 3x25 | 5.6 | 1.2 | 1.8 | 20.8 | ||
| 3x35 | 6.7 | 1.2 | 1.8 | 23.2 | ||
| 3x50 | 8 | 1.4 | 1.8 | 26.9 | ||
| 3x70 | 9.4 | 1.4 | 1.9 | 30.1 | ||
| 3x95 | 11 | 1.6 | 2.1 | 34.7 | ||
| 3x120 | 12.4 | 1.6 | 2.2 | 38.0 | ||
| 3x150 | 13.8 | 1.8 | 2.3 | 42.1 | ||
| 3x185 | 15.3 | 2 | 2.5 | 46.5 | ||
| 3x240 | 17.5 | 2.2 | 2.7 | 52.5 | ||
| 3x300 | 19.5 | 2.4 | 2.8 | 58.0 | ||
| 3x400 | 22.6 | 2.6 | 3.1 | 66.1 | ||
| Three cores+1(unarmoured) | ||||||||
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||||
| mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm | ||
| 3x 16/10 | 4.5 | 3.6 | 1 | 1 | 1.8 | 19.0 | ||
| 3x 25/16 | 5.6 | 4.5 | 1.2 | 1 | 1.8 | 22.6 | ||
| 3x 35/16 | 6.7 | 4.5 | 1.2 | 1 | 1.8 | 25.3 | ||
| 3x 50/25 | 8.0 | 5.6 | 1.4 | 1.2 | 1.9 | 29.6 | ||
| 3x 70/35 | 9.4 | 6.7 | 1.4 | 1.2 | 2.0 | 33.2 | ||
| 3x 95/50 | 11.0 | 8.0 | 1.6 | 1.4 | 2.2 | 38.4 | ||
| 3x120/70 | 12.4 | 9.4 | 1.6 | 1.4 | 2.3 | 42.0 | ||
| 3x150/70 | 13.8 | 9.4 | 1.8 | 1.4 | 2.5 | 46.6 | ||
| 3x185/95 | 15.3 | 11.0 | 2 | 1.6 | 2.6 | 51.6 | ||
| 3x240/120 | 17.5 | 12.4 | 2.2 | 1.6 | 2.9 | 58.3 | ||
| 3x300/150 | 19.5 | 13.8 | 2.4 | 1.8 | 3.1 | 64.5 | ||
| 3x400/185 | 22.6 | 15.3 | 2.6 | 2 | 3.3 | 73 | ||
| Four cores(unarmored) | ||||||
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
| mm^2 | mm | mm | mm | mm | ||
| 4x1.5 | 1.4 | 0.8 | 1.8 | 10.8 | ||
| 4x2.5 | 1.8 | 0.8 | 1.8 | 11.8 | ||
| 4x4 | 2.3 | 1 | 1.8 | 14.0 | ||
| 4x6 | 2.8 | 1 | 1.8 | 15.2 | ||
| 4x10 | 3.6 | 1 | 1.8 | 17.1 | ||
| 4x16 | 4.5 | 1 | 1.8 | 19.3 | ||
| 4x25 | 5.6 | 1.2 | 1.8 | 22.9 | ||
| 4x35 | 6.7 | 1.2 | 1.8 | 25.6 | ||
| 4x50 | 8 | 1.4 | 1.9 | 29.9 | ||
| 4x70 | 9.4 | 1.4 | 2.0 | 33.5 | ||
| 4x95 | 11 | 1.6 | 2.2 | 38.7 | ||
| 4x120 | 12.4 | 1.6 | 2.3 | 42.3 | ||
| 4x150 | 13.8 | 1.8 | 2.5 | 46.9 | ||
| 4x185 | 15.3 | 2 | 2.6 | 51.9 | ||
| 4x240 | 17.5 | 2.2 | 2.9 | 58.6 | ||
| 4x300 | 19.5 | 2.4 | 3.1 | 64.8 | ||
| 4x400 | 22.6 | 2.6 | 3.3 | 73.8 | ||
| Multi-cores(unarmoured) | ||||||
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
| mm^2 | mm | mm | mm | mm | ||
| 5x1.5 | 1.4 | 0.8 | 1.8 | 11.7 | ||
| 7x1.5 | 1.4 | 0.8 | 1.8 | 12.6 | ||
| 10x1.5 | 1.4 | 0.8 | 1.8 | 15.6 | ||
| 12x1.5 | 1.4 | 0.8 | 1.8 | 16.1 | ||
| 14x1.5 | 1.4 | 0.8 | 1.8 | 16.8 | ||
| 19x1.5 | 1.4 | 0.8 | 1.8 | 18.6 | ||
| 21x1.5 | 1.4 | 0.8 | 1.8 | 19.5 | ||
| 24x1.5 | 1.4 | 0.8 | 1.8 | 21.6 | ||
| 30x1.5 | 1.4 | 0.8 | 1.8 | 22.8 | ||
| 40x1.5 | 1.4 | 0.8 | 1.8 | 27.7 | ||
| 48x1.5 | 1.4 | 0.8 | 1.9 | 28.2 | ||
| 61x1.5 | 1.4 | 0.8 | 1.9 | 30.9 | ||
| 5x2.5 | 1.8 | 0.8 | 1.8 | 12.8 | ||
| 7x2.5 | 1.8 | 0.8 | 1.8 | 13.8 | ||
| 10x2.5 | 1.8 | 0.8 | 1.8 | 17.2 | ||
| 12x2.5 | 1.8 | 0.8 | 1.8 | 17.7 | ||
| 14x2.5 | 1.8 | 0.8 | 1.8 | 18.6 | ||
| 19x2.5 | 1.8 | 0.8 | 1.8 | 20.6 | ||
| 21x2.5 | 1.8 | 0.8 | 1.8 | 21.6 | ||
| 24x2.5 | 1.8 | 0.8 | 1.8 | 24.0 | ||
| 30x2.5 | 1.8 | 0.8 | 1.8 | 25.4 | ||
| 40x2.5 | 1.8 | 0.8 | 2.0 | 31.1 | ||
| 48x2.5 | 1.8 | 0.8 | 2.0 | 31.7 | ||
| 61x2.5 | 1.8 | 0.8 | 2.1 | 34.7 | ||
4.Contact us
If you need low voltage cable, medium voltage cable, control cable, rubber cable,
ABC cable, ACSR, underground cable, armoured cable, XLPE cable, PVC cable,
- Similar Products
$20.00
1000 Meters (MOQ)
AAC AAAC ACSR Bare Aluminum Conductor and Wire Cable
Hebei Panghao Electrical Technology Co., Ltd.