| INPUT | AC voltage | | ·Single phase | 1×230V(220,240) | ·Three phase | 3×400V(380,415) | Input voltage tolerance | ±10% | Input Wiring | 3 Phase 3 Wirse or 3 Phase 4 Wires | Input frequecny | 50Hz(60Hz) | Input frequecny tolerance | ±5% | Input Protection | Thermic Magnetic Overcurrent protection via MCCB |
OPTIONS | Rectifier | Other input voltage(1×110 to 3×690VAC) | Harmonic filter for THDi≈15% | Blocking diode | Surge and Lightning protections | Voltage ripple filter | Bettery | Battery circuit protection box | Battery reversed polarity detection | Battery low-voltage disconnection contactor (LVD) | Battery room temperature sensor | Battery cabinet / rack | Battery monitoring system | |
System | Parallel configurations | Dropping diodes/DC-DC converter | Earth fault monitoring | Internal cabinet lighting | Anti-condensation heater | Output breaker | Front-panel analog meters/digtal meters | DC distribution | Temparature compensation | AC high and AC low alarm/protection | DC high and DC low alarm/protection | AC fault alarm | LED test function | Mechanical | Other frame colour | Up to IP55 external | Plate thickness | Specified cabinet identification (tag, nameplate) | Communication | Modbus TCP/IP | modbus RTU(RS485) | DNP3.0 protocol | Volt-free contacts | Transducers 4-20mA | Remote monitoring |
| | OUTPUT | Nominal DC voltage | 24/48/110/125/220/240/400 | Output voltage range | 0-1.5×nominal voltage (adjustable) | Nominal DC current | 10-1500A | Output current range | 0-1.1×nominal current(adjustable) | Voltage stability | ±1% in float mode, input within tolerance | Voltage ripple | 1% RMS(with battery connected) | Current Limitation | Battery current limitation can be adjusted | Filtering | L-C Filter | Output Protection | Short Circuit, NH Fuse and Overvoltage protection |
BATTERY | Type | Lead acid or nickel cadmium, vented or recombination and Lithium battery |
COMMUNICATION | Communication | RS232, Modbus RTU |
GENERAL DATA | Operating temperature | 0 to 50 °C | Storage temperature | -20 to +70 °C | Relative humidity | < 95 % non condensing | Operating altitude | 1000 m max without derating | Cooling | Fan cooling or Natural cooling according to rating | Efficiency | 90% according to rating | External protection | IP20 | Noise (at 1m in front of the unit) | 55 - 65 dB according to rating | Cabinet color | RAL 7035 | Dimensions | Varying according to ratings & options |
STANDARDS | IEC60146-1-1:2009 | Semiconductor converters - Specification of basic requirements | IEC62040-1:2008+AMD1:2013 | Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS in restricted access locations | IEC62040-2:2006 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements | IEC61439-1:2011 | Low voltage switchgear and controlgear assemblies - Part 1: General rules | IEC60529:1989+ AMD1:1999 | Degrees of protection provided by enclosures (IP Code) | IEC60076-11:2004 | Power transformers - Part 11: Dry type transformers |
European Directives | Low voltage directive: 2006/95/EC and 2014/35/EU EMC directive: 2004/108/EC and 2014/30/EU CE Mark |
|